TE CONNECTIVITY Moisture Protection Selection Guide

of 3
【选型】TE Connectivity(泰科)KPSI传感器附件和选件产品选型指南
选型目录:
Installation Hardware
Replaceable and Interchangeable Nose Caps
Corrosion Protection
Moisture Protection
Additional Accessories
Digital Installation Hardware Digital Displays/ Digital Displays
KPSI ACCESSORY CATAL
OG
TE CONNECTIVITY SENSORS
/// LIGHTNING PROTECTION FOR KPSI TRANSDUCERS
07/2016
Page
10
MOISTURE PROTECTION
Two solutions are offered to provide protection against moisture
incursion on transducers with vented gage reference pressure
format. The choice of which solution to utilize depends o
n the ability to provide periodic maintenance and the acc
uracy required
for level measurement.
VENT FILTER
Vent Filters provide the highest accuracy
capability and utilize indicating desiccant to
prevent moisture from entering the vent tube
and damaging transducers with vented gage
reference pressure format. The desiccant will
turn from blue to pink when exposed to moisture
indicating the need for maintenance. All KPSI
vented gage transducers are shipped with our
SuperDry Vent Filter. This vent filter design
prevents moisture from entering the vent tube
for at least one year without maintenance, at no
additional cost. The vent filters are 6.0 in (15.3
cm) long with a 0.75" diameter.
The KPSI 811 Stainless Steel Vent Filter is
housed in a 316 stainless steel body containing
desiccant to provide vent tube moisture
protection for a minimum of five years without
maintenance. A Gore-Tex filter plug provides
the vent filter with atmospheric pressure
reference. These vent filters are 2.75 inches
(7.0 cm) long with a 0.75 inch (1.9 cm) diameter.
ANEROID BELLOWS
The Aneroid Bellows is a maintenance-free
alternative to desiccant filters for moisture
protection on vented gage transducers. Made of
flexible neoprene material attached to a
polycarbonate mounting bracket, the bellows
fluctuates with changes in atmospheric
pressure maintaining a constant barometric
reference. Note that the use of the bellows
results in a closed reference pressure system
subject to zero shift errors induced by changing
temperatures of up to 0.003 psi/ºC. The bellows
is not recommended for use with accuracy
requirements of ±0.25% FS or better, nor for
ranges < 2 psi.
PN:
810
SuperDry Vent Filter
PN:
811
Stainless Steel Vent Filter
PN:
815
Aneroid Bellows
Model
811
Model 815
【选型】TE Connectivity(泰科)KPSI传感器附件和选件产品选型指南
选型目录:
Installation Hardware
Replaceable and Interchangeable Nose Caps
Corrosion Protection