Delta High Efficiency Computing Product Selection Guide
AS Series Delta Compact Modular Mid-range PLC
选型目录:
Compact Modular Mid-range PLC Introduction
High Efficiency Computing
Accurate Axis Control- Positioning Control Solution
AS500 Motion Control Solution
AX-3 CODESYS Control Solution
Simple Installation
AS Series Industrial Network Solution
Programming & Diagnosis
Models and Specifications
3
Delta's self-developed AS100 / 200 / 300 Series CPU provides 32-bit
high-performance computing and a real-time operation system. As the
core of a high-efficiency controller, it helps increase the productivity and
adaptability of demanding equipment.
▪
Max. number of inputs / outputs: 1,024
▪
Max. extension ability: 32 modules
Basic instruction / Boolean operation
High Efficiency Computing
Advanced CPU Performance
■
High Execution Speed
AS100 / 200 / 300 series CPU
AS500 series CPU
AX-3 series CPU
25 ns
50 ns
2 ~ 5 ns
4
CAN protocol: The signal is sent via
optimized CAN bus protocol. The I/O update
time is not significantly prolonged even with
more modules.
Optimized I/O updates
■
Common in the industry:
PLC module bus update via
serial communication
■
AS Series:
PLC module bus update via
optimized CAN protocol
Permanent data backup, no battery required
PLC power off
PLC programs
permanent backup
Latched area
permanent backup
PLC power off
RTC
keeps accurate time
Install general
CR 1620
battery
■
Non-volatile memory material
for data backup
■
Lithium button battery for
Real Time Clock (RTC) function
CPU #1 #2 #3 #4 #5 #6 #n
CPU #1 #2 #3 #4 #5 #6 #n
0.1
ms 0.1
ms
Industrial communication bus greatly
Industrial communication bus greatly
enhances stability and speed
enhances stability and speed
0.1
ms 0.1
ms*n
CPU #1 #2 #3 #4 #5 #6 #n
CPU #1 #2 #3 #4 #5 #6 #n
More modules reduce the update
More modules reduce the update
speed
speed
Optimized Execution Efficiency
■
General Scanning Method
■
AS Series Scanning Method
Standard simplex scanning which sequentially
goes through instructions by fixed schedule
operation (e.g. I/O update). It significantly
affects overall execution speed.
Fixed schedule operations will be
automatically processed by the CPU
background program when scanning starts.
This significantly enhances
execution speed.
1 scan time
1 scan time
Program
Out
In
Program
Out
In
1 scan time
1 scan time
1 scan time
Program
Out
In
Program
Out
In
Program
Out
In
General serial communication: the signal is
sequentially sent from the 1
st
module to the
last module. The more modules the longer
I/O update time it takes.
Note: The real updating performance will be different for different
Note: The real updating performance will be different for different
extension modules.
extension modules.
AS Series Delta Compact Modular Mid-range PLC
选型目录:
Compact Modular Mid-range PLC Introduction
High Efficiency Computing
Accurate Axis Control- Positioning Control Solution
AS500 Motion Control Solution
AX-3 CODESYS Control Solution
Simple Installation
AS Series Industrial Network Solution
Programming & Diagnosis
Models and Specifications