WAGO Multilevel Installation Terminal Blocks Selection Guide
TOPJOB S Rail-Mount Terminal Block Systems
选型目录:
Rail-Mount Terminal Blocks TOPJOBS Introduction
Through Terminal Blocks and Ground Conductor Terminal Blocks
Multilevel Rail-Mount Terminal Blocks
Disconnect/Test Terminal Blocks
Fuse Plugs on Carrier Terminal Blocks
Sensor Terminal Blocks and Actuator Terminal Blocks
Diode Terminal Blocks and LED Terminal Blocks
Accessories for Rail-Mount Terminal Blocks TOPJOB S
Pluggable Rail-Mount Terminal Blocks Overview
X-COMS-SYSTEM-MINI Carrier Terminal Blocks
X-COMS-SYSTEM-MINI 1-Conductor Female Plugs and 2-Conductor Female Plugs
X-COMS-SYSTEM Carrier Terminal Blocks
X-COMS-SYSTEM 1-Conductor Female Plugs
X-COMS-SYSTEM for Ex ec Applications
Multilevel Installation Terminal Blocks
Supply Terminal Blocks
Miniature Through Terminal Blocks and Ground Conductor Terminal Blocks
High-Current Rail-Mount Terminal Blocks
Marking Systems
Mounting Accessories and Tools
Test and Measurement Devices
Item Number Index
216
www.wago.com
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
MULTILEVEL INSTALLATION TERMINAL
BLOCKS
For Building Installations and Industrial Applications
Maximum Touch-Proof Safety
Multilevel Installation Terminal Blocks with N-Disconnect Slide Links for Mounting
with N-busbar
Maximum Wiring Space
• Transparent busbar cover provides touch protection for the
busbar.
• Cover enables user to see if N-disconnect slide links are con
-
nected to the N-busbar.
• Configure larger circuit groups
• Automatically and permanently connect to the N-bus
-
bar by simply sliding the screwless N-discon
-
nect link
• 2003 and 2005 Series Multilevel Installation Terminal Blocks
feature extremely compact dimensions while providing all of
the functionality of a 4 mm² or 6 mm² terminal block.
• Maximize wiring space in standard distribution cabinets.
2003 Series
Multilevel installation ter
-
minal blocks with an N-dis
-
connect slide link up to
4 mm² (12 AWG), 32 A
2005 Series
Multilevel installation
terminal blocks with an
N-disconnect slide link
up to 6 mm² (10 AWG),
36 A
217
www.wago.com
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
Insulation Resistance Measurement –
Fast and Safe
Multilevel Installation Terminal Blocks with Internal N-Disconnection for Mounting
without N-Busbar
Multilevel Installation Terminal
Blocks as Fuse Terminal Block
• Disconnect N-potential via pivoting knife disconnect.
• Plug N/L test adapter into the free shaft to link N and L con
-
ductors.
• Measurement with connected live conductors halves testing
times and protects the connected devices against high test
voltage.
• Configure smaller circuit groups, e.g., in installa
-
tions with multiple RCD potentials.
• Internal N-knife disconnect enables N-poten
-
tial disconnection within the terminal
block by opening the the
knife disconnect.
• Multilevel installation terminal blocks carry a centered slot,
allowing them to be used as fuse terminal blocks in a standard
distribution board’s cutout.
• The fuse plugs for microfuses can be used in combination
with an end and intermediate plate (1 mm/0.039 inch thick).
2003 Series
Multilevel Installation Terminal
Blocks with an Internal N-Dis
-
connection
up to 4 mm² (12 AWG), 28 A
2016 Series
Supply Terminal
Blocks up to 16 mm²
(4 AWG), 76 A
218
www.wago.com
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
Installation
Installation Rail-Mount Terminal Blocks TOPJOB® S
Inserting a conductor via push-in termination.
Solid conductors with cross-sections from either one size
above, or up to two sizes below, the rated cross-section
can be simply pushed in – no tools needed.
Inserting a conductor via operating tool.
Connecting fine-stranded conductors without ferrules, or
small cross-sectional conductors that cannot be pushed
in, is performed similarly to the original CAGE CLAMP® –
just use an operating tool.
All conductor types at a glance
Mounting busbars on busbar carriers: Insert busbar ends
onto large busbar carriers (2009-305) or onto supply ter
-
minal blocks with an integrated busbar carrier.
Removing the separator plate from the busbar carrier or
from the N-disconnect terminal block.
Inserting the separator plate into the busbar carrier to pro
-
tect the N-busbar against accidental contact.
Inserting separator plate removed from N-disconnect ter
-
minal block.
Touch-proof N-busbar via inserted separator plate
Perforations make it possible to fit the carrier to all Instal
-
lation Rail-Mount Terminal Blocks TOPJOB® S using a sin
-
gle part.
The compact busbar carrier (1.5 mm thick), which is placed
every 200 mm, provides additional busbar support for lon
-
ger assemblies.
The busbar transparent cover (Item No. 777-303) protects
the busbar against accidental contact and makes it easy
to see which terminal blocks are connected to the busbar.
Tool-operated N-disconnect slide link
Push-in CAGE CLAMP®
terminates the following
copper conductors:
solid “s”
stranded “st”
fine-stranded “f-st”,
also with tinned
single strands
219
www.wago.com
RR
N
PE
L
max.
500 V
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
N-potential disconnection via N-knife disconnect within a
terminal block assembly without a busbar.
For multilevel installation terminal blocks with internal
N-disconnection, test plug adapters can be inserted into
the free vertical test slot when the N-potential is discon
-
nected.
Test plug adapters for both individual N-potential mea
-
surement and insulation resistance measurement of the
connected N- and L-potentials are available.
Multilevel installation terminal block fitted with an N/L-test
plug adapter for quick and safe insulation resistance mea
-
surement of the connected N- and L-potentials
Multilevel installation terminal block fitted with an N-test
plug adapter for insulation resistance measurement of the
N-potential
Single-fuse plugs can be used in combination with 1 mm
thick end and intermediate plates on carrier terminal
blocks without an N-knife disconnect.
Double-fuse plugs with 5 x 25 mm glass cartridge fuses
can be used on carrier terminal blocks without an N-knife
disconnect in standard terminal block width.
fine-stranded,
tip-bonded
fine-stranded,
with ferrule
(gastight crimped)
fine-stranded,
with pin terminal
(gastight crimped)
Insert the operating tool between the staggered jumpers,
then lift up the jumper.
Commoning two potentials in one single jumper slot via
extremely slim staggered jumpers.
220
www.wago.com
42,3 mm/
1.67 in
52,5 mm/2.07 in
96 mm/3.78 in
42,3 mm/
1.67 in
52,5 mm/2.07 in
96 mm/3.78 in
42,3 mm/
1.67 in
52,5 mm/2.07 in
96 mm/3.78 in
42,3 mm/
1.67 in
52,5 mm/2.07 in
96 mm/3.78 in
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
2.5 (4) mm²; 2003 Series
Multilevel Installation Terminal Block TOPJOB® S; with N-Disconnect Slide Link
Technical Data
Technical Data
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
250 V/4 kV/3; 24 A (32 A)
2
400 V/6 kV/3
2
400 V/6 kV/3; 24 A (32 A)
2
I
N
24 A (32 A)
Terminal block width: 5.2 mm / 0.205 inch
Terminal block width: 5.2 mm / 0.205 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
Multilevel installation terminal block; with N-disconnect
slide link; gray
Multilevel installation terminal block; gray
Item No.
Pack. Unit
Item No.
Pack. Unit
NT/L/PE
2003-7641
50
L/L
2003-7642
50
N/L
2003-7649
50
Multilevel installation terminal block; with N-disconnect
slide link; gray
Multilevel installation terminal block; gray
Item No.
Pack. Unit
Item No.
Pack. Unit
NT/L
2003-7640
50
L
2003-7650
50
LT/L
2003-7659
50
N
2003-7651
50
Multilevel installation terminal block; gray
N/L/PE
2003-7646
50
L/L/PE
2003-7645
50
Accessories; 2003 Series
Appropriate marking systems: WMB/WMB Inline/Marking strips
1
Conductor range: 0.25 ... 4 mm² “s+f-st”;
Push-in termination: 1 ... 4 mm² “s” and 1 ... 2.5 mm²
“insulated ferrules, 12 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
2
250 V / 400 V = rated voltage
4 kV / 6 kV = rated impulse voltage
3 = pollution degree
250 V/4 kV potential – ground
400 V/6 kV potential – potential
Please observe the application notes:
Jumpers, from page 166
Testing accessories, page 165
Marking, from page 266
Approvals and corresponding ratings,
visit www.wago.com
End and intermediate plate; 0.8 mm thick
orange
2003-7692
100 (25)
Busbar carrier; not suitable as an end stop; snaps onto
DIN-35 rail; 1.5 mm thick
blue
2009-304
100 (25)
Busbar carrier; with end stop function and detachable
separator plate; snaps onto DIN-35 rail; 7.5 mm thick
blue
2009-305
25
Busbar; tin-plated; 1000 mm long; copper (10 x 3) mm
I
N
140 A
210-133
1
Busbar cover; 1000 mm long
transparent
777-303
1
1-conductor N-disconnect terminal block; I
N
76 A;
16 mm²; 12 mm wide
blue
2016-7714
20
1-conductor N-disconnect terminal block; I
N
125 A;
35 mm²; 16 mm wide
blue
785-613
15
2-conductor ground terminal block; 16 mm²; 12 mm wide
green-yellow
2016-7607
20
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
2-conductor ground terminal block; 35 mm²; 16 mm wide
green-yellow
785-607
15
Connector; for busbar; with blue cover; 2.5 ... 16 mm²
blue
210-281
100 (50)
Connector; for busbar; 2.5 ... 35 mm²
unplated
209-105
50
Lock-out; prevents reclosing of slide link; snap-on type
orange
2003-7300
100 (25)
Insulation stop; 5 pcs/strip; 0.25 ... 0.5 mm²
light gray
2002-171
200 (25)
Insulation stop; 5 pcs/strip; 0.75 ... 1 mm²
dark gray
2002-172
200 (25)
Push-in type jumper bar; insulated; I
N
25 A; light gray
2-way
2002-402
25
3-way
2002-403
25
4-way
2002-404
25
5-way
2002-405
25
6-way
2002-406
25
7-way
2002-407
25
8-way
2002-408
25
9-way
2002-409
25
10-way
2002-410
25
Push-in type jumper bar; insulated; I
N
25 A; light gray
1 to 3
2002-433
25
1 to 4
2002-434
25
1 to 5
2002-435
25
1 to 6
2002-436
25
1 to 7
2002-437
25
1 to 8
2002-438
25
1 to 9
2002-439
25
1 to 10
2002-440
25
221
www.wago.com
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
Adjacent jumper for continuous commoning; insulated;
I
N
25 A, light gray
2-way
2002-400
25
Adjacent jumper for continuous commoning; insulated;
I
N
25 A; 1 to 3
light gray
2002-423
25
red
2002-423/000-005
25
blue
2002-423/000-006
25
Staggered jumper; insulated; I
N
25 A; light gray
2-way
2002-472
25
3-way
2002-473
25
4-way
2002-474
25
5-way
2002-475
25
6-way
2002-476
25
7-way
2002-477
25
8-way
2002-478
25
9-way
2002-479
25
10-way
2002-480
25
11-way
2002-481
25
12-way
2002-482
25
Customized staggered jumper; insulated; with contact
lugs broken off at the factory and circuit printing; I
N
25 A;
light gray
1-3
2002-473/011-000
25
1-3-5
2002-475/011-000
25
1-3-5-7
2002-477/011-000
25
1-3-5-7-9
2002-479/011-000
25
1-3-5-7-9-11
2002-481/011-000
25
Push-in type wire jumper; insulated; 1.5 mm² conductor
cross-section; I
N
18 A
L = 60 mm
2009-412
100 (10)
L = 110 mm
2009-414
100 (10)
L = 250 mm
2009-416
100 (10)
Test plug adapter; for 4 mm Ø test plug
gray
2009-174
100 (25)
Testing tap; for max. 2.5 mm²
gray
2009-182
100 (25)
Marking strip; plain; 11 mm wide; 50 m reel
white
2009-110
1
WMB Inline, plain; 1,500 WMB markers (5 mm)/reel;
5 ... 5.2 mm stretchable
white
2009-115
1
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
plain
793-5501
5
Operating tool; 3.5 mm and 2.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-309
50 (1)
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
Operating tool; 3.5 mm and 5.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-310
50 (1)
Operating tool; blade 3.5 x 0.5 mm; with a partially
insulated shaft
210-720
1
TOPJOB® S – Terminal Blocks for Every Application
• Push-in termination of solid conductors in small distribu
-
tion boards saves time and money.
• Operating errors can be prevented as all Terminal
Blocks for building installations are equipped with
push-in connection technology.
• The use of standard accessories reduces order-pro
-
cessing and warehousing costs.
• The busbar position is the same, making Installation Ter
-
minal Blocks TOPJOB® S compatible with standard
Installation Terminal Blocks TOPJOB®.
For the construction and operation of power installations
in fire-prone, hazardous locations or public buildings –
such as conference centers, stores, hospitals, schools,
theaters or hotels – the DIN VDE 0100-710 or DIN VDE
0100-718 standards shall be observed. DIN VDE
0100-482 shall also be observed for fire-prone, hazardous
locations. These VDE regulations mandate that every neu
-
tral conductor must be provided with a disconnection
device so, e.g., insulation resistance measurement is pos
-
sible for every circuit without disconnecting the N-con
-
ductor.
WAGO’s N-disconnect terminal blocks meet this require
-
ment.
Application note:
N-disconnect slide links, used in installation terminal
blocks, consist of switch contacts that are opened and
then closed again as part of regular circuit testing. To
guarantee a reliable connection, a corrosion-resistant
contact area is required on the N-busbar.
Historically, uninsulated copper busbars that have been
cleaned/stripped of any possible corrosion prior to install
can be used in dry, pollution-free locations.
According to DIN VDE 0100-520 (VDE 0100, Part 520),
installation equipment exposed to contamination or corro
-
sive substances (e.g., water) that promote corrosion or
deterioration, must be protected or made of a corrosion-
or wear-resistant material. In these cases, tinned copper
busbars guarantee a reliable connection.
WAGO only offers tinned copper busbars.
222
www.wago.com
110 mm/4.33 in
56,7 mm/2.32 in
45,2 mm/1.78 in
110 mm/4.33 in
56,7 mm/2.32 in
45,2 mm/1.78 in
110 mm/4.33 in
56,7 mm/2.32 in
45,2 mm/1.78 in
56,7 mm/2.32 in
54,7 mm/2.15 in
45,2 mm/1.78 in
110 mm/4.33 in
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
2.5 (4) mm²; 2003 Series
Multilevel Installation Terminal Block TOPJOB® S; with Internal N-Disconnection
End and intermediate plate; 0.8 mm thick
orange
2003-6692
100 (25)
Insulation stop; 5 pcs/strip; 0.25 ... 0.5 mm²
light gray
2002-171
200 (25)
Insulation stop; 5 pcs/strip; 0.75 ... 1 mm²
dark gray
2002-172
200 (25)
Push-in type jumper bar; insulated; I
N
25 A; light gray
2-way
2002-402
25
3-way
2002-403
25
4-way
2002-404
25
5-way
2002-405
25
6-way
2002-406
25
7-way
2002-407
25
8-way
2002-408
25
9-way
2002-409
25
10-way
2002-410
25
Push-in type jumper bar; insulated; I
N
25 A; light gray
1 to 3
2002-433
25
1 to 4
2002-434
25
1 to 5
2002-435
25
1 to 6
2002-436
25
1 to 7
2002-437
25
1 to 8
2002-438
25
1 to 9
2002-439
25
1 to 10
2002-440
25
Push-in type wire jumper; insulated; 1.5 mm² conductor
cross-section; I
N
18 A
L = 60 mm
2009-412
100 (10)
L = 110 mm
2009-414
100 (10)
L = 250 mm
2009-416
100 (10)
Multilevel installation terminal block; with pivoting knife
disconnect; gray
Multilevel installation terminal block; gray
Multilevel installation terminal block; gray
Item No.
Pack. Unit
Item No.
Pack. Unit
Item No.
Pack. Unit
NT/L/PE
2003-6641
50
L/L
2003-6642
50
N/L/PE
2003-6646
50
LT/L/PE
2003-6644
50
N/L
2003-6649
50
L/L/PE
2003-6645
50
Accessories; item-specific
N/L-test plug adapter; for vertical test slot; gray
2-pole
2003-499
100 (25)
N-test plug adapter; for vertical test slot; gray
1-pole
2003-500
100 (25)
Multilevel installation terminal block; gray
Item No.
Pack. Unit
L
2003-6650
50
N
2003-6651
50
Accessories; 2003 Series
Appropriate marking systems: WMB/WMB Inline/Marking strips
Technical Data
Technical Data
Technical Data
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
250 V/4 kV/3; 20 A (25 A)
2
300 V, 20 A
U
400 V/6 kV/3
2
300 V, 20 A
U
250 V/4 kV/3; 24 A (28 A)
2
300 V, 20 A
U
400 V/6 kV/3; 20 A (25 A)
2
300 V, 20 A
2
I
N
24 A (28 A)
300 V, 20 A
2
400 V/6 kV/3; 24 A (28 A)
2
300 V, 20 A
2
Terminal block width: 5.2 mm / 0.205 inch
Terminal block width: 5.2 mm / 0.205 inch
Terminal block width: 5.2 mm / 0.205 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
223
www.wago.com
RR
N
PE
L
max.
500 V
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
1
Conductor range: 0.25 ... 4 mm² “s+f-st”;
Push-in termination: 1 ... 4 mm² “s” and 1 ... 2.5 mm²
“insulated ferrules, 12 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
2
250 V / 400 V = rated voltage
4 kV / 6 kV = rated impulse voltage
3 = pollution degree
250 V/4 kV potential – ground
400 V/6 kV potential – potential
Please observe the application notes:
Jumpers, from page 166
Testing accessories, page 165
Marking, from page 266
Approvals and corresponding ratings,
visit www.wago.com
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
Staggered jumper; insulated; I
N
25 A; light gray
2-way
2002-472
25
3-way
2002-473
25
4-way
2002-474
25
5-way
2002-475
25
6-way
2002-476
25
7-way
2002-477
25
8-way
2002-478
25
9-way
2002-479
25
10-way
2002-480
25
11-way
2002-481
25
12-way
2002-482
25
Customized staggered jumper; insulated; with contact
lugs broken off at the factory and circuit printing; I
N
25 A;
light gray
1-3
2002-473/011-000
25
1-3-5
2002-475/011-000
25
1-3-5-7
2002-477/011-000
25
1-3-5-7-9
2002-479/011-000
25
1-3-5-7-9-11
2002-481/011-000
25
Adjacent jumper for continuous commoning; insulated;
I
N
25 A, light gray
2-way
2002-400
25
Adjacent jumper for continuous commoning; insulated;
I
N
25 A; 1 to 3
light gray
2002-423
25
red
2002-423/000-005
25
blue
2002-423/000-006
25
Test plug adapter; for 4 mm Ø test plug
gray
2009-174
100 (25)
Testing tap; for max. 2.5 mm²
gray
2009-182
100 (25)
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
Marking strip; plain; 11 mm wide; 50 m reel
white
2009-110
1
WMB Inline, plain; 1,500 WMB markers (5 mm)/reel;
5 ... 5.2 mm stretchable
white
2009-115
1
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
plain
793-5501
5
Operating tool; 3.5 mm and 2.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-309
50 (1)
Operating tool; 3.5 mm and 5.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-310
50 (1)
Operating tool; blade 3.5 x 0.5 mm; with a partially
insulated shaft
210-720
1
For multilevel installation terminal blocks with internal
N-disconnection, test plug adapters can be inserted into
the free vertical test slot when the N-potential is discon
-
nected.
Test plug adapters for both individual N-potential mea
-
surement and insulation resistance measurement of the
connected N- and L-potentials are available.
224
www.wago.com
110 mm/4.33 in
56,7 mm/2.32 in
45,2 mm/1.78 in
110 mm/4.33 in
56,7 mm/2.32 in
45,2 mm/1.78 in
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
2.5 (4) mm²; 2003 Series
Multilevel Installation Terminal Block TOPJOB® S
1
Conductor range: 0.25 ... 4 mm² “s+f-st”;
Push-in termination: 1 ... 4 mm² “s” and 1 ... 2.5 mm²
“insulated ferrules, 12 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
2
250 V / 400 V = rated voltage
4 kV / 6 kV = rated impulse voltage
3 = pollution degree
250 V/4 kV potential – ground
400 V/6 kV potential – potential
Maximum current depends on accessories used.
Please observe the application notes:
Jumpers, from page 166
Testing accessories, page 165
Marking, from page 266
Approvals and corresponding ratings,
visit www.wago.com
Multilevel installation terminal block; carrier terminal
block without knife disconnect; gray
Multilevel installation terminal block; carrier terminal
block without knife disconnect; black upper-deck, brown
middle-deck, green-yellow lower-deck printing
Item No.
Pack. Unit
Item No.
Pack. Unit
N/L/PE
2003-6640
50
P2/P1/PE
2003-6643
50
L/L/PE
2003-6662
50
Multilevel installation terminal block; carrier terminal
block without knife disconnect; blue middle-deck;
green-yellow lower-deck printing; gray
Multilevel installation terminal block; carrier terminal
block without knife disconnect; brown upper-deck, black
middle-deck, green-yellow lower-deck printing
L/N/PE
2003-6661
50
P1/P2/PE
2003-6660
50
Accessories; 2003 Series
Appropriate marking systems: WMB/WMB Inline/Marking strips
Technical Data
Technical Data
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
250 V/4 kV/3; 20 A (25 A)
2
250 V, 6,3 A
U
250 V/4 kV/3; 20 A (25 A)
2
250 V, 6,3 A
U
400 V/6 kV/3; 20 A (25 A)
2
300 V, 20 A
2
400 V/6 kV/3; 20 A (25 A)
2
300 V, 20 A
2
Terminal block width: 5.2 mm / 0.205 inch
Terminal block width: 5.2 mm / 0.205 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
N/L-test plug adapter; for vertical test slot; gray
2-pole
2003-499
100 (25)
N-test plug adapter; for vertical test slot; gray
1-pole
2003-500
100 (25)
End and intermediate plate; 0.8 mm thick
orange
2003-6692
100 (25)
Fuse plug with pull-tab; for 5 x 20 mm glass cartridge
fuse
Electrical ratings are given by the fuse.
gray
2004-911
50
End and intermediate plate; only for use with fuse plugs;
1 mm thick
orange
2003-6693
100 (25)
Double-fuse plug; for 5 x 20 mm glass cartridge fuse
Electrical ratings are given by the fuse.
gray
2003-911
25
End and intermediate plate; 1 mm thick; only for use with
double-fuse plugs
orange
2003-6694
100 (25)
Push-in type jumper bar; insulated; I
N
25 A; light gray
2-way
2002-402
25
3-way
2002-403
25
4-way
2002-404
25
5-way
2002-405
25
6-way
2002-406
25
7-way
2002-407
25
8-way
2002-408
25
9-way
2002-409
25
10-way
2002-410
25
Push-in type jumper bar; insulated; I
N
25 A; light gray
1 to 3
2002-433
25
1 to 4
2002-434
25
1 to 5
2002-435
25
1 to 6
2002-436
25
1 to 7
2002-437
25
1 to 8
2002-438
25
1 to 9
2002-439
25
1 to 10
2002-440
25
Push-in type wire jumper; insulated; 1.5 mm² conductor
cross-section; I
N
18 A
L = 60 mm
2009-412
100 (10)
L = 110 mm
2009-414
100 (10)
L = 250 mm
2009-416
100 (10)
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
Staggered jumper; insulated; I
N
25 A; light gray
2-way
2002-472
25
3-way
2002-473
25
4-way
2002-474
25
5-way
2002-475
25
6-way
2002-476
25
7-way
2002-477
25
8-way
2002-478
25
9-way
2002-479
25
10-way
2002-480
25
11-way
2002-481
25
12-way
2002-482
25
Customized staggered jumper; insulated; with contact
lugs broken off at the factory and circuit printing; I
N
25 A;
light gray
1-3
2002-473/011-000
25
1-3-5
2002-475/011-000
25
1-3-5-7
2002-477/011-000
25
1-3-5-7-9
2002-479/011-000
25
1-3-5-7-9-11
2002-481/011-000
25
Adjacent jumper for continuous commoning; insulated;
I
N
25 A, light gray
2-way
2002-400
25
Adjacent jumper for continuous commoning; insulated;
I
N
25 A; 1 to 3
light gray
2002-423
25
red
2002-423/000-005
25
blue
2002-423/000-006
25
Test plug adapter; for 4 mm Ø test plug
gray
2009-174
100 (25)
Testing tap; for max. 2.5 mm²
gray
2009-182
100 (25)
225
www.wago.com
RR
N
PE
L
max.
500 V
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
Single-fuse plugs can be used in combination with 1 mm
thick end and intermediate plates on carrier terminal
blocks without an N-knife disconnect.
Multilevel installation terminal block fitted with an N/L-test
plug adapter for quick and safe insulation resistance mea
-
surement of the connected N- and L-potentials
Multilevel installation terminal block fitted with an N-test
plug adapter for insulation resistance measurement of the
N-potential
Test plug adapters for both individual N-potential mea
-
surement and insulation resistance measurement of the
connected N- and L-potentials are available.
Accessories; 2003 Series
Appropriate marking systems:
WMB/WMB Inline/Marking strips
Marking strip; plain; 11 mm wide; 50 m reel
white
2009-110
1
WMB Inline, plain; 1,500 WMB markers (5 mm)/reel;
5 ... 5.2 mm stretchable
white
2009-115
1
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
plain
793-5501
5
Operating tool; 3.5 mm and 2.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-309
50 (1)
Operating tool; 3.5 mm and 5.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-310
50 (1)
Operating tool; blade 3.5 x 0.5 mm; with a partially
insulated shaft
210-720
1
226
www.wago.com
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
2003 Series
Double-Fuse Plug TOPJOB® S on Carrier Terminal Block 2.5 (4) mm²
Accessories; for fuse plugs
Appropriate marking systems:
WMB/Marking strips
Multilevel installation terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
N/L/PE
2003-6640
50
Multilevel installation terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
L/N/PE
2003-6661
50
Multilevel installation terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
P2/P1/PE
2003-6643
50
Multilevel installation terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
P1/P2/PE
2003-6660
50
End and intermediate plate; 0.8 mm thick
orange
2003-6692
100 (25)
End and intermediate plate; 1 mm thick; only for use with
double-fuse plugs
orange
2003-6694
100 (25)
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
plain
793-5501
5
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
F1, ..., F10
(10x)
794-5615
5
F11, ..., F20
(10x)
794-5616
5
F21, ..., F30
(10x)
794-5617
5
F31, ..., F40
(10x)
794-5618
5
F41, ..., F50
(10x)
794-5619
5
2-conductor carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
gray
2002-1961
50
End and intermediate plate; 1 mm thick
orange
2002-1992
100 (25)
gray
2002-1991
100 (25)
Double-deck carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
L/L
2002-2961
50
Double-deck carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
L/N
2002-2963
50
Double-deck carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
L/L
2002-2941
50
End and intermediate plate; 1 mm thick
orange
2002-2992
100 (25)
gray
2002-2991
100 (25)
Shorting link; 5 x 20 mm; allows the fuse plug to be used
as a disconnect plug
I
N
6.3 A
281-503
250 (25)
2-conductor carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
gray
2002-1661
50
End and intermediate plate; 1 mm thick
orange
2002-1692
100 (25)
gray
2002-1691
100 (25)
3-conductor carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
gray
2002-1761
50
End and intermediate plate; 1 mm thick
orange
2002-1792
100 (25)
gray
2002-1791
100 (25)
4-conductor carrier terminal block;
0.25 ... 2.5 (4) mm² / 22 ... 12 AWG
Terminal block width: 5.2 mm / 0.205 inch
gray
2002-1861
50
End and intermediate plate; 1 mm thick
orange
2002-1892
100 (25)
gray
2002-1891
100 (25)
End plate for fuse terminal blocks; 2 mm thick
orange
2002-992
100 (25)
gray
2002-991
100 (25)
Double-fuse plug; for 5 x 20 mm glass cartridge fuse
Electrical ratings are given by the fuse.
Double-fuse plug; for 5 x 20 mm glass cartridge fuse;
with LED; gray
Electrical ratings are given by the fuse and blown fuse
indication. Leakage current in case of a blown fuse: LED
0.25 mA
Color
Item No.
Pack. Unit
Item No.
Pack. Unit
gray
2003-911
50
230 V
2003-911/1000-923
50
Accessories; for fuse plugs
Appropriate marking systems: WMB/Marking strips
Technical Data
Technical Data
250 V / I
N
6.3 A
250 V / I
N
6.3 A
Plug width: 10.4 mm / 0.409 inch
Plug width: 10.4 mm / 0.409 inch
Length for 2002-1661 – 66.5 mm / 2.62 inch
2-conductor carrier terminal block
Length for 2002-1761 – 76.8 mm / 3.02 inch
3-conductor carrier terminal block
Length for 2002-1861 – 87.5 mm / 3.45 inch
4-conductor carrier terminal block
Length for 2002-1961 – 72.9 mm / 2.87 inch
2-conductor carrier terminal block with additional
jumper slot
Length for 2002-2961 – 108 mm / 4.25 inch
Double-deck carrier terminal block
Length for 2003-6640 – 110 mm / 4.33 inch
Multilevel Installation Terminal Block
Approvals and corresponding ratings,
visit www.wago.com
227
www.wago.com
2003-911
2003-911/....-....
Glass cartridge fuses 5 x 20
Series
Item No.
Overload and
short circuit protection
Short circuit
protection only
Individual
argmt.
Group
argmt.
Individual
argmt.
Group
argmt.
Fuse terminal blocks
1.6 W
1.6 W
2.5 W
2.5 W
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
When selecting glass cartridge fuses, make sure that the
maximum power loss listed below is not exceeded. The
power loss is determined according to IEC or EN 60947-
7-3/VDE 0611-6 at 23°C. The temperature rise of the ter
-
minal blocks must be checked according to their applica
-
tion and mounting. Higher ambient temperatures
represent an additional impact on fuse cartridges. There
-
fore, in such applications, the rated current must be
reduced if necessary. More details are available from the
manufacturers.
Double-fuse plugs with 5 x 25 mm glass cartridge fuses
can be used on carrier terminal blocks without an N-knife
disconnect in standard terminal block width.
228
www.wago.com
123,9 mm/4.88 in
41,7 mm/
1.64 in
70,5 mm/2.78 in
123,9 mm/4.88 in
41,7 mm/
1.64 in
70,5 mm/2.78 in
123,9 mm/4.88 in
41,7 mm/
1.64 in
70,5 mm/2.78 in
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
4 (6) mm²; 2005 Series
Multilevel Installation Terminal Block TOPJOB® S; with N-Disconnect Slide Link
End and intermediate plate; 1 mm thick
orange
2005-7692
100 (25)
Busbar carrier; not suitable as an end stop; snaps onto
DIN-35 rail; 1.5 mm thick
blue
2009-304
100 (25)
Busbar carrier; with end stop function and detachable
separator plate; snaps onto DIN-35 rail; 7.5 mm thick
blue
2009-305
25
Busbar; tin-plated; 1000 mm long; copper (10 x 3) mm
I
N
140 A
210-133
1
Busbar cover; 1000 mm long
transparent
777-303
1
Lock-out; prevents reclosing of slide link; snap-on type
orange
2005-7300
100 (25)
1-conductor N-disconnect terminal block; I
N
76 A;
16 mm²; 12 mm wide
blue
2016-7714
20
1-conductor N-disconnect terminal block; I
N
125 A;
35 mm²; 16 mm wide
blue
785-613
15
2-conductor ground terminal block; 16 mm²; 12 mm wide
green-yellow
2016-7607
20
2-conductor ground terminal block; 35 mm²; 16 mm wide
green-yellow
785-607
15
Connector; for busbar; with blue cover; 2.5 ... 16 mm²
blue
210-281
100 (50)
Connector; for busbar; 2.5 ... 35 mm²
unplated
209-105
50
Insulation stop; 5 pcs/strip; 0.25 ... 0.5 mm²
light gray
2004-171
200 (25)
Insulation stop; 5 pcs/strip; 0.75 ... 1 mm²
dark gray
2004-172
200 (25)
Push-in type jumper bar; insulated; I
N
32 A; light gray
2-way
2004-402
25
3-way
2004-403
25
4-way
2004-404
25
5-way
2004-405
25
6-way
2004-406
25
7-way
2004-407
25
8-way
2004-408
25
9-way
2004-409
25
10-way
2004-410
25
Push-in type jumper bar; insulated; I
N
32 A; light gray
1 to 3
2004-433
25
1 to 4
2004-434
25
1 to 5
2004-435
25
1 to 6
2004-436
25
1 to 7
2004-437
25
1 to 8
2004-438
25
1 to 9
2004-439
25
1 to 10
2004-440
25
Test plug adapter; for 4 mm Ø test plug
gray
2009-174
100 (25)
Testing tap; for max. 2.5 mm²
gray
2009-182
100 (25)
Marking strip; plain; 11 mm wide; 50 m reel
white
2009-110
1
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
plain
793-5501
5
Operating tool; 3.5 mm and 2.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-309
50 (1)
Operating tool; 3.5 mm and 5.5 mm blade width; for
Installation Terminal Blocks TOPJOB® S
2009-310
50 (1)
Operating tool; blade 3.5 x 0.5 mm; with a partially
insulated shaft
210-720
1
Technical Data
Technical Data
Technical Data
0.5 ... 4 (6) mm²
1
20 ... 10 AWG
0.5 ... 4 (6) mm²
1
20 ... 10 AWG
0.5 ... 4 (6) mm²
1
20 ... 10 AWG
250 V/4 kV/3; 32 A (36 A)
2
400 V/6 kV/3
2
250 V/4 kV/3; 32 A (36 A)
2
400 V/6 kV/3; 32 A (36 A)
2
I
N
32 A (36 A)
400 V/6 kV/3; 32 A (36 A)
2
Terminal block width: 6.2 mm / 0.244 inch
Terminal block width: 6.2 mm / 0.244 inch
Terminal block width: 6.2 mm / 0.244 inch
L
11 ... 13 mm / 0.43 ... 0.51 inch
L
11 ... 13 mm / 0.43 ... 0.51 inch
L
11 ... 13 mm / 0.43 ... 0.51 inch
Multilevel installation terminal block; with N-disconnect
slide link; gray
Multilevel installation terminal block; gray
Multilevel installation terminal block; gray
Bestellnr.
VPE
Bestellnr.
VPE
Bestellnr.
VPE
NT/L/PE
2005-7641
50
L/L
2005-7642
50
N/L/PE
2005-7646
50
N/L
2005-7649
50
L/L/PE
2005-7645
50
Accessories; 2005 Series
Appropriate marking systems: WMB/Marking strips
229
www.wago.com
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
1
Conductor range: 0.5 ... 6 mm² “s+f-st”;
Push-in termination: 1.5 ... 6 mm² “s” and 1.5 ... 4 mm²
“insulated ferrules; 12 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
2
250 V/400 V = rated voltage
4 kV/6 kV = rated impulse voltage
3 = pollution degree
250 V/4 kV potential – ground
400 V/6 kV potential – potential
Please observe the application notes:
Testing accessories, page 165
Marking, from page 266
Approvals and corresponding ratings,
visit www.wago.com
Application note:
N-disconnect slide links, used in installation terminal blocks, consist of switch contacts that are opened and then closed
again as part of regular circuit testing. To guarantee a reliable connection, a corrosion-resistant contact area is required
on the N-busbar.
Historically, uninsulated copper busbars that have been cleaned/stripped of any possible corrosion prior to install can
be used in dry, pollution-free locations.
According to DIN VDE 0100-520 (VDE 0100, Part 520), installation equipment exposed to contamination or corrosive
substances (e.g., water) that promote corrosion or deterioration, must be protected or made of a corrosion- or wear-re
-
sistant material. In these cases, tinned copper busbars guarantee a reliable connection.
WAGO only offers tinned copper busbars.
230
www.wago.com
35,3 mm/1.39 in
60,1 mm/2.37 in
38,1 mm/
1.5 in
37,7 mm/
1.48 in
36,7 mm/1.44 in
56,6 mm/2.23 in
38,1 mm/
1.5 in
36,7 mm/1.44 in
67,3 mm/2.65 in
36,5 mm/1.44 in
67,3 mm/2.65 in
38,1 mm/
1.5 in
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
2002 Series; 2006 Series; 2010 Series; 2016 Series
N-Disconnect Terminal Block, Power Distribution Disconnect Terminal Block TOPJOB® S
2-conductor N-disconnect terminal block
Color
Item No.
Pack. Unit
blue
2002-7214
50
2-conductor power distribution disconnect terminal
block
gray
2002-7211
50
Accessories; item-specific
End and intermediate plate; 0.8 mm thick
orange
2002-7292
100 (25)
Lock-out; prevents reclosing of slide link; snap-on type
orange
2005-7300
100 (25)
Busbar carrier; not suitable as an end stop; snaps onto
DIN-35 rail; 1.5 mm thick
blue
2009-304
100 (25)
Busbar carrier; with end stop function and detachable
separator plate; snaps onto DIN-35 rail; 7.5 mm thick
blue
2009-305
25
Busbar; tin-plated; 1000 mm long; copper (10 x 3) mm
I
N
140 A
210-133
1
Busbar cover; 1000 mm long
transparent
777-303
1
Connector; for busbar; with blue cover; 2.5 ... 16 mm²
blue
210-281
100 (50)
Connector; for busbar; 2.5 ... 35 mm²
unplated
209-105
1
Accessories; for N-conductor and power distribution disconnect terminal blocks
Appropriate marking systems: WMB/Marking strips
Marking strip; plain; 11 mm wide; 50 m reel
white
2009-110
1
WMB marking card; white; 10 strips with 10 markers/card;
5 ... 5.2 mm stretchable
plain
793-5501
5
1-conductor N-disconnect terminal block
1-conductor N-disconnect terminal block
1-conductor N-disconnect terminal block
1-conductor N-disconnect terminal block
Color
Item No.
Pack. Unit
Color
Item No.
Pack. Unit
Color
Item No.
Pack. Unit
Color
Item No.
Pack. Unit
blue
2002-7114
50
blue
2006-7114
50
blue
2010-7114
25
blue
2016-7114
25
1-conductor power distribution disconnect terminal
block
1-conductor power distribution disconnect terminal
block
1-conductor power distribution disconnect terminal
block
1-conductor power distribution disconnect terminal
block
gray
2002-7111
50
gray
2006-7111
50
gray
2010-7111
25
gray
2016-7111
25
Appropriate through and ground conductor terminal
blocks, see page 42
Appropriate through and ground conductor terminal
blocks, see page 48
Appropriate through and ground conductor terminal
blocks, see page 49
Appropriate through and ground conductor terminal
blocks, see page 50
Accessories; item-specific
Accessories; item-specific
Accessories; item-specific
Accessories; item-specific
End and intermediate plate; 0.8 mm thick
End and intermediate plate; 1 mm thick
End and intermediate plate; 1 mm thick
End and intermediate plate; 1 mm thick
orange
2002-7192
100 (25)
orange
2006-7192
100 (25)
orange
2010-7192
100 (25)
orange
2016-7192
100 (25)
Lock-out; prevents reclosing of slide link; snap-on type
Lock-out; prevents reclosing of slide link; snap-on type
Lock-out; prevents reclosing of slide link; snap-on type
Lock-out; prevents reclosing of slide link; snap-on type
orange
2005-7300
100 (25)
orange
2006-7300
100 (25)
orange
2006-7300
100 (25)
orange
2006-7300
100 (25)
Technical Data
Technical Data
Technical Data
Technical Data
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
0.5 ... 6 (10) mm²
2
20 ... 8 AWG
0.5 ... 10 (16) mm²
3
20 ... 6 AWG
0.5 ... 16 (25 “f-st”) mm²
3
20 ... 4 AWG
250 V/4 kV/3
5
250 V/4 kV/3
5
250 V/4 kV/3
5
250 V/4 kV/3
5
I
N
32 A
I
N
51 A
I
N
57 A
I
N
65 A
Terminal block width: 5.2 mm / 0.205 inch
Terminal block width: 7.5 mm / 0.295 inch
Terminal block width: 10 mm / 0.394 inch
Terminal block width: 12 mm / 0.472 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
L
13 ... 15 mm / 0.51 ... 0.59 inch
L
17 ... 19 mm / 0.67 ... 0.75 inch
L
18 ... 20 mm / 0.71 ... 0.79 inch
231
www.wago.com
36,5 mm/1.44 in
69,4 mm/2.73 in
38,1 mm/
1.5 in
WAGO Rail-Mount Terminal Blocks TOPJOB® S
WAGO Installation Rail-Mount Terminal Blocks TOPJOB® S
Removing the separator plate from the busbar carrier or
from the N-disconnect terminal block.
Inserting separator plate removed from N-disconnect ter
-
minal block.
Inserting the separator plate into the busbar carrier to pro
-
tect the N-busbar against accidental contact.
Touch-proof N-busbar via inserted separator plate
N-conductor disconnect terminal blocks:
For the construction and operation of power installations
in fire-prone, hazardous locations or public buildings –
such as conference centers, stores, hospitals, schools,
theaters or hotels – the DIN VDE 0100-710 or DIN VDE
0100-718 standards shall be observed. DIN VDE
0100-482 shall also be observed for fire-prone, hazardous
locations. These VDE regulations mandate that every neu
-
tral conductor must be provided with a disconnection
device so, e.g., insulation testing is possible for every cir
-
cuit without disconnecting the N-conductor.
WAGO’s N-disconnect terminal blocks meet this require
-
ment.
Power distribution disconnect terminal blocks:
According to DIN VDE 0100-710, “Requirements for oper
-
ating facilities, rooms and special installations – medical
facilities,” equipotential bonding conductors shall be run
on a potential equalization busbar. The potential equaliza
-
tion busbar and the protective ground conductor busbar
must be mounted in a common housing and be connected
to each other using a disconnectable copper conductor of
minimum 16 mm² (6 AWG). Furthermore, all equipotential
bonding conductors must be connected to the potential
equalization busbar and clearly arranged so they can be
disconnected individually and accessed at any time.
Depending on their function, they must be provided with
captive marking.
WAGO’s power distribution disconnect terminal blocks
meet these requirements.
1-conductor N-disconnect terminal block
1-conductor N-disconnect terminal block
1-conductor N-disconnect terminal block
1-conductor N-disconnect terminal block
Color
Item No.
Pack. Unit
Color
Item No.
Pack. Unit
Color
Item No.
Pack. Unit
Color
Item No.
Pack. Unit
blue
2002-7114
50
blue
2006-7114
50
blue
2010-7114
25
blue
2016-7114
25
1-conductor power distribution disconnect terminal
block
1-conductor power distribution disconnect terminal
block
1-conductor power distribution disconnect terminal
block
1-conductor power distribution disconnect terminal
block
gray
2002-7111
50
gray
2006-7111
50
gray
2010-7111
25
gray
2016-7111
25
Appropriate through and ground conductor terminal
blocks, see page 42
Appropriate through and ground conductor terminal
blocks, see page 48
Appropriate through and ground conductor terminal
blocks, see page 49
Appropriate through and ground conductor terminal
blocks, see page 50
Accessories; item-specific
Accessories; item-specific
Accessories; item-specific
Accessories; item-specific
End and intermediate plate; 0.8 mm thick
End and intermediate plate; 1 mm thick
End and intermediate plate; 1 mm thick
End and intermediate plate; 1 mm thick
orange
2002-7192
100 (25)
orange
2006-7192
100 (25)
orange
2010-7192
100 (25)
orange
2016-7192
100 (25)
Lock-out; prevents reclosing of slide link; snap-on type
Lock-out; prevents reclosing of slide link; snap-on type
Lock-out; prevents reclosing of slide link; snap-on type
Lock-out; prevents reclosing of slide link; snap-on type
orange
2005-7300
100 (25)
orange
2006-7300
100 (25)
orange
2006-7300
100 (25)
orange
2006-7300
100 (25)
1
Conductor range: 0.25 ... 4 mm² “s+f-st”;
Push-in termination: 1 ... 4 mm² “s” and 1 ... 2.5 mm²
“insulated ferrules, 12 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
2
Conductor range: 0.5 ... 10 mm² “s+f-st”;
Push-in termination: 2.5 ... 10 mm² “s” and
2.5 ... 6 mm² “insulated ferrules; 12 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
3
Conductor range: 0.5 ... 16 mm² “s+f-st”;
Push-in termination: 4 ... 16 mm² “s” and 4 ... 10 mm²
“insulated ferrules; 18 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
4
Conductor range: 0.5 ... 16 mm² “s+f-st”, 25 mm² “f-st”;
Push-in termination: 6 ... 16 mm² “s” and 6 ... 16 mm²
“insulated ferrules; 18 mm”
Depending on the conductor characteristic, a conduc
-
tor with a smaller cross section can also be inserted
via push-in termination.
5
250 V = rated voltage
4 kV = rated impulse voltage
3 = pollution degree
Approvals and corresponding ratings,
visit www.wago.com
Technical Data
Technical Data
Technical Data
Technical Data
0.25 ... 2.5 (4) mm²
1
22 ... 12 AWG
0.5 ... 6 (10) mm²
2
20 ... 8 AWG
0.5 ... 10 (16) mm²
3
20 ... 6 AWG
0.5 ... 16 (25 “f-st”) mm²
3
20 ... 4 AWG
250 V/4 kV/3
5
250 V/4 kV/3
5
250 V/4 kV/3
5
250 V/4 kV/3
5
I
N
32 A
I
N
51 A
I
N
57 A
I
N
65 A
Terminal block width: 5.2 mm / 0.205 inch
Terminal block width: 7.5 mm / 0.295 inch
Terminal block width: 10 mm / 0.394 inch
Terminal block width: 12 mm / 0.472 inch
L
10 ... 12 mm / 0.39 ... 0.47 inch
L
13 ... 15 mm / 0.51 ... 0.59 inch
L
17 ... 19 mm / 0.67 ... 0.75 inch
L
18 ... 20 mm / 0.71 ... 0.79 inch
您正在使用的浏览器版本过低,将不能正常浏览产品选型内容。