Laird Thermal Systems‘ Next Generation Heat Exchanger LA5000 Economically Provides Full-Time Operation for Immersion Cooling in Data Centers
LA5000 heat exchanger maximizes uptime for immersion cooling systems.
Today, data centers housing large data files with high-traffic and fast-performing CPUs, GPUs, and servers are experiencing continued increases in the capacities and support required. Increased server rack density paired with surging power flow supporting advanced server computing power and performance is resulting in an increasing amount of heat generation within data centers. Consequently, the traditional methods of air cooling are not meeting the thermal management requirements of today’s servers, CPUs, and GPUs. Immersion cooling utilizes heat exchangers to dissipate this generated heat simultaneously preventing system failures while lowering operating costs and improving energy efficiency.
Immersion cooling submerges hardware into a heat-conducting dielectric liquid that recycles drawn-out heat into a cooler liquid, expanding the processing abilities confined to smaller sizes and spaces. Two-phase immersion cooling involves combining the dielectric liquid with the heat generated from the submerged hardware to initiate boiling which transforms the dielectric liquid into a gas. The gas rises towards a cold-water condenser causing condensation to fall back into the immersion pool. This results in faster heat dissipation due to the phase change of the immersion fluid, and heat density. Since immersion cooling removes the need for cooling fans, this contributes to the lower power usage effectiveness rating. Electronic equipment temperature can be reduced and controlled, while also exhibiting significantly higher efficiency levels when compared to traditional air-cooled systems.
Laird Thermal Systems’ LA5000 is a 5000-watt liquid-to-air water heat exchanger designed to operate slightly above ambient temperatures serves as an excellent source of cold water for the system condenser and is ideal for immersion cooling applications. The robust design provides full-time operation, continually monitoring system liquid level, flow rate, and temperature, and alerts users of the need for preventative maintenance to avoid costly failure. The semi-closed hydraulic system contributes to the system’s increased uptime by reducing evaporative losses and preventing air from entering the liquid which could result in bio growth and cause damage to the pump.
“When it comes to high-performance and cloud computing based in smaller data centers, immersion cooling with heat exchangers relieve data center operators and managers from worrying about overheating and wasteful power consumption,” says Greg Ducharme, Product Director at Laird Thermal Systems. “Our data center heat exchangers provide a high coefficient of performance (COP) that delivers efficient, low power operation and maximize uptime and system performance.”
Applications
Analytical
Liquid Cooling Systems
- |
- +1 赞 0
- 收藏
- 评论 0
本文由玄子转载自Laird Thermal Systems News,原文标题为:Laird Thermal Systems’ Next Generation Heat Exchanger Economically Provides Full-Time Operation for Immersion Cooling in Data Centers,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Laird Thermal Systems’ LA5000 Liquid-to-air-based Heat Exchanger System for Cooling X-ray in Industrial Scanners
Liquid cooling systems offer a high reliability, high performance, cost-effective and robust solution for dissipating the large amount of heat generated in industrial X-ray scanners. A wide range of standard and custom liquid cooling systems using liquid-to-air, chiller-based heat transfer configurations in various cooling capacities can meet any industrial X-ray application requirement. Laird Thermal Systems’ LA5000 is a liquid-to-air-based heat exchanger system offering the high heat pumping capacity and reliability needed for industrial scanners.
GRL Busbar System Empowers Alibaba‘s Langfang Big Data Center, Promoting Cloud Infrastructure in The 5G Era
GRL, a third-tier supplier to Alibaba, provided compact three-phase busbar systems for the Langfang Big Data Center to meet small space and multi-circuit needs. The system ensures quick backup circuit activation upon main circuit failure, addressing Alibaba‘s challenge of high space requirements and potential losses.
Keeping Cool with Data Center Temperature Sensors
Data center temperature sensors are the eyes and ears of your climate control system. These tiny devices provide real-time data on temperature and some insight into potential humidity levels throughout your facility. They come in various forms, each suited to different applications.
HEAT EXCHANGERS AND ENCLOSURE COOLING
型号- 5360,5340,HXC-2000,5320,5300,HXC-2500,HXI-500,HXI™,HXC™,HX™,HXC-1800,5300 SERIES,HXC™ SERIES,5350,5330,HX5360,HXI-1000,5310,HXC-1500,HXC-3000,HXI-1500,5370,HXI™ SERIES,HXC-2250,HX-800,HXI-1500+,HX-400,HX™ SERIES,HX-200
莱尔德热系统推出新一代5000W液体-空气水热交换器LA5000,可延长浸入式冷却系统的正常运行时间
莱尔德热系统公司的LA5000是一种5000W的液体-空气水热交换器,其设计工作温度略高于环境温度,能够为系统冷凝器提供极好的冷水来源,因此是浸入式冷却应用的理想选择。
What are the benefits of using liquid instead of air cooling systems?
Liquid heat exchangers can reduce the thermal resistance of conventional heat sink fan dissipation mechanisms by a factor of 10 or more, which makes it much more efficient. This is due to the poor thermal properties of air versus coolants such as water. Liquid cooling systems have a more rapid cool down time, which means less time to reach the desired temperature. While conventional air cooling systems push air all around the system, and can potentially add heat from surrounding hot electronics, liquid cooling systems are equipped with a heat exchanger that routes heat away through a liquid circuit. Air-cooling systems in the higher capacity range often require larger fans, which can increase noise as well as the size of the system.
【产品】5000W水热交换器LA5000系列,使用更高性能的热交换器和更高效的风扇,是冷却工业应用的理想选择
莱尔德热系统推出LA5000液冷系统,扩展了其水热交换器产品线。这款5000W的水热交换器紧凑且性能可靠,可以从液体回路中带走大量的热量。LA5000热交换器旨在最大化系统的正常运行时间。
Laird Thermal Systems Introduces 5000 Watt Heat Exchanger for Industrial Applications
Laird Thermal Systems has expanded its line of water heat exchangers with the introduction of the LA5000 Liquid Cooling System. As a water heat exchanger, the 5000-watt unit offers dependable compact performance while removing large amounts of heat from a liquid circuit. Designed to maximize system uptime, the LA5000 heat exchanger is ideal for immersion cooling and bulk heat removal in particle accelerators, linear accelerators, cyclotrons, semiconductor fabrication equipment, medical X-ray, and industrial X-ray scanners.
Heat Exchangers, Chillers, and Coolant Distribution Units (CDUs)
型号- RC045,6000 SERIES,6000,5000,4000,5000 SERIES,ES SERIES,4000 SERIES,ASPEN,ASPEN SERIES,RC011,RC022,RC030
Laird Thermal Systems(莱尔德热系统)液体冷却系统产品选型指南
目录- Introduction Benefits & Applications of Liquid Cooling Systems Nextreme™ Recirculating Chillers Liquid Heat Exchangers Custom Liquid Cooling Systems Featured Application: Medical Imaging
型号- 1510.00,WL1500,385901-001,VRC2400,VRC4500,NRC5000,WL3004,387008451,1550.00,LA5000,WL1000,385911-015,1520.00,387009925,OW4002,385910-043,387010178,387010179,NRC2400,1505.00,38701 0181,1264.00,1155.00,1104.00,VRC1200,WW5001,387002779,NRC400,WW3001,1515.00,WL500,WL2000,387005774,387005598,OL4503,385912-029,NRC1200,385910-015
Laird Thermal Systems Introduces 5000Watt Heat Exchanger for Industrial Applications
The LA5000 Series recirculating liquid-to-air heat exchanger offers improved thermal performance maximizing system uptime. As a water heat exchanger, the 5000-watt unit offers dependable compact performance while removing large amounts of heat from a liquid circuit.
电子商城
服务
使用FloTHERM和Smart CFD软件,提供前期热仿真模拟、结构设计调整建议、中期样品测试和后期生产供应的一站式服务,热仿真技术团队专业指导。
实验室地址: 深圳 提交需求>
登录 | 立即注册
提交评论