Technical Standards for Fuses
1. Rated zero power resistance
PPTC thermistors should be packaged according to zero power resistance levels, and the resistance range should be indicated on the outer packaging. After the withstand voltage and current resistance tests, the change rate of the resistance before each group of samples is extremely poor δ| After Ri - Before Ri - (After Rj - Before Rj)/Before Rj | ≤ 100%.
2. PTC effect
A material has a PTC (Positive Temperature Coefficient) effect, which means that the resistance of the material increases with increasing temperature. Most metal materials have the PTC effect. In these materials, the PTC effect is manifested as a linear increase in resistance with increasing temperature, which is commonly referred to as the linear PTC effect.
3. Nonlinear PTC effect
The material undergoing phase transformation will exhibit a phenomenon where the resistance rapidly increases by several to more than ten orders of magnitude along a narrow temperature range, known as the nonlinear PTC effect. Various types of conductive polymers exhibit this effect, such as polymer PTC thermistors. These conductive polymers are very useful for manufacturing overcurrent protection devices.
4. Initial resistance Rmin
Before being installed in the circuit, test the resistance value of the polymer PTC thermistor of the self resetting fuse series at an ambient temperature of 25℃.
5. Rmax
Under room temperature conditions, the self resetting fuse series polymer PTC thermistor acts or reflows.
The maximum resistance value is measured after one hour of installation in the circuit board.
6. Minimum resistance (Rmin)/maximum resistance (Rmax)
At a specified ambient temperature, such as 25℃, the resistance value of a specific model of self resetting fuse series polymer thermistor before installation in the circuit will be within a specified range, that is, between the minimum value (Rmin) and the maximum value (Rmax). This value is listed in the resistance column of the specification.
Fig.1
- |
- +1 赞 0
- 收藏
- 评论 0
本文由三年不鸣转载自XC News,原文标题为:fast blow or slow blow fuse for amplifier.Technical standards for fuses,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关研发服务和供应服务
相关推荐
The Impact of Fuse Aging on Usage
After the fuse ages, there is no danger of generating the current that should be cut off and the fuse not blowing. The aging of a fuse is equivalent to a decrease in the rated value (current) rather than an increase, resulting in the circuit being cut off at a small overload current or pulse.
Temperature Characteristics of Current Fuses
Current fuses exhibit specific temperature characteristics that play a crucial role in their performance and reliability. The behavior of a current fuse in response to temperature changes is determined by several factors.
Factors Affecting the Lifespan of Fuses and Their Evaluation
In this article, XC tells factors that affect the lifespan of fuses.
旭程(XC)保险丝选型指南
目录- Company Profile Fuse User's Manual Fuse Auto Fuse Fuse Holder Thermostat
型号- 06F,3S,C0015302Z,C0040302Z,3T,10C,06T,C0060303Z,4F,KSD9700,C0030301Z,6CH,C7500301Z,4T,C0015301Z,C0070303Z,4TE,C0040303Z,8TE,C0025302Z,5C,KSD305,5F,5G,C4000302Z,5H,9L,KSD301,C2000302Z,C0030302Z,10FV,C0020301Z,5S,C7500302Z,5T,C0010302Z,24F,12F,32F,C0080303Z,5SH,6B,6C,C0025301Z,6F,6G,24T,6H,12T,C3000301Z,C4000301Z,C5000301Z,2F,C2000301Z,C0030303Z,32T,R3-13,5GH,R3-12,R3-11,5CH,6S,C0020302Z,6T,2T,5TE,XC-1,BS1362,C0010301Z,C3000302Z,5TR,3F,3G,C5000302Z,C1000302Z,XC-2,C0050303Z,C0035302Z,C0020303Z
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
Selection of Current Fuses in Automotive Circuits
In automotive circuits, the selection of current fuses is of great significance for ensuring the safe operation of the vehicle. There are several key factors to consider when choosing a current fuse for an automotive circuit.
Explanation of Parameters in the PPTC Specification for Self Healing Fuses
This is very simple. As long as you know the meaning represented by the parameters in the specification book, you can clearly and quickly view the PTC specification book for self recovery fuses.
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
The Installation Precautions for Current Fuses
The installation of current fuses is crucial for ensuring the safety and proper functioning of electrical circuits. Here are some important installation precautions to keep in mind.
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
The Role of Current Fuses in Smart Meters
Current fuses play a vital role in smart meters. Firstly, they provide protection against overcurrent events. Smart meters are used to measure and manage electricity consumption accurately. However, electrical circuits can sometimes experience sudden surges in current due to various reasons such as power outages and subsequent restoration, short circuits in the electrical grid, or the malfunction of connected electrical appliances.
Precautions for Using Fuses
The fuse is connected in series with the circuit, installed vertically, and installed on each phase line; Fuses are not allowed to be installed on the neutral line of a two phase three wire or three-phase four wire circuit.The power input terminal of the spiral fuse should be connected to the center point of the base, and the output wire should be connected to the threaded shell; This insurance is used in places with vibrations.
What is A Self Recovery Fuse
Self recovery fuse is an overcurrent electronic protection component that uses a polymer organic polymer under high pressure, high temperature, and sulfurization reaction conditions.After mixing with conductive particle materials, it is processed through a special process. Habitually applying PPTC (Polymer Positive Temperature).
Several Factors Influence the Lifetime of Current Fuses
The lifetime of a current fuse is influenced by several factors. Firstly, the current rating of the fuse plays a crucial role. If a fuse is constantly operating near or at its rated current, it will experience more heat buildup and stress over time, which can shorten its lifetime.