Classification of Fuses
Fuses are divided into two categories: high voltage and low voltage. High voltage fuses for 3kV-35kV; Low voltage fuses are used for AC 220V, 380V, and DC 220V, 440V.
High voltage fuses are divided into indoor and outdoor types, and the model description is as follows:
For example, RN1-3/150-200 is indoor. The rated voltage is 3kV, the rated current is 150A, and the breaking capacity is 200MVA.
Indoor models include RN1, RN2, RN3, RN5, RN6, etc., outdoor models include RW3, RW4, RW10, etc., and DC electric vehicles use RNZ, RNZ1, etc.
Low voltage fuses are commonly classified into three categories: plug-in, tubular, and spiral. It can also be divided into three types: open type, semi closed type, and closed type.
The open type is not used alone and is often combined with a knife switch; One or both ends of the semi enclosed tube are opened, and the molten particles are sprayed out in a certain direction. Please pay attention to safety when using; Closed type commonly includes plug-in type, unfilled tube type, filled tube type, and filled spiral type. The meaning of the letters for low-voltage fuses is as follows:
R-fuse; C-plug-in; L-spiral; M - Closed tube type; S-fast; T - Packed tube type. For example, RC1 and RC1A are plug-in; RM - unfilled tube type; RT0, RL1, and RLS are respectively filled tube type and filled spiral type.
Fig.1
- |
- +1 赞 0
- 收藏
- 评论 0
本文由三年不鸣转载自XC News,原文标题为:bimetal thermostat for samsung refrigerator.Classification of Fuses and Fuses,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Why Expulsion Euses are the Backbone of High Voltage Protection?
In the realm of high voltage electrical systems, ensuring robust protection against faults is paramount. Among the protective devices available, expulsion expulsion fuses are vital for maintaining system integrity and safety.
Temperature Characteristics of Current Fuses
Current fuses exhibit specific temperature characteristics that play a crucial role in their performance and reliability. The behavior of a current fuse in response to temperature changes is determined by several factors.
Factors Affecting the Lifespan of Fuses and Their Evaluation
In this article, XC tells factors that affect the lifespan of fuses.
旭程(XC)温控器选型指南
目录- 公司介绍 Company Profile 温控器 Thermostat 保险丝 Fuses 企业资质与专利 Qualification and Patents Certifications
型号- C0015302Z,9K7.SK-B5,KSD305系列,9K7.SK-B3,CG-B,CG-A,SK-B1系列,9K7CG-XXX,SK-B5系列,KSD301系列,KSD307B,SK-A1,KSD307 SERIES,SK-A4,C0015301Z,9K7.SK-C2,SK-C2系列,C0025302Z,C4000302Z,KT SERIES,9K7.JW-A072,C2000302Z,CG-B系列,C0080303Z,9K7.SK-B11,JW-C系列,KSD305B,JW,KSD305-XXXX/XXXX,SK-C2,9K7SK-XXXX/XXXXX,C4000301Z,C5000301Z,SK,CG SERIES,9K4307-XXXX/XXXX,C0020302Z,CG,KT,KSD9700 SERIES,SK-B1,C5000302Z,C1000302Z,C0050303Z,SK-B5,C0035302Z,C0020303Z,C0040302Z,KSD307系列,KSD301-XXX/XXXXXX/XXX,9K7KT-XXXX/XXXXX,9K7.SK-F3,SK-F5系列,JW-B系列,C0060303Z,KSD9700,C0030301Z,KT系列,C7500301Z,C0070303Z,C0040303Z,SK-A1系列,9K9.9700-XXXXXXX,KSD305,KSD307,KT-A2,KT-A1,KSD301,C0030302Z,JW SERIES,JW系列,C0020301Z,C7500302Z,C0010302Z,9K4.307B,JW-A系列,CG-A1,C0025301Z,CG系列,KSD9700系列,C3000301Z,C2000301Z,C0030303Z,KT-A系列,SK SERIES,JW-B,JW-C,SK系列,KSD301 SERIES,KSD305 SERIES,CG-B2,C0010301Z,SK-F5,C3000302Z,SK-F6,9K7JW-XXXX,CG-A系列,KSD307-XXXX/XXXX,KT-A,9K4.307
Eaton Bussmann(伊顿巴斯曼) 中压熔断器(保险丝)选型指南
目录- Medium Voltage Fuses Introduction E-rated Fuses R-rated Fuses British Standard Dimensioned IEC Fuses for Motor Circuit Protection DIN Dimensioned IEC Fuses Potential Transformer Fuses British Standard IEC Fuses for Oil-Filled Switchgear Fast-Acting Fuses EEI-NEMA Type K&T and Type H&N Fuses BBU Boric Acid Fuses Fuseclips for Medium&High Voltage Fuses
型号- JCL-B-6R,MV155F1DCX65E,225-007-938,225-007-939,ECL155-200E,A055C1DORO-40E,A155C1DORO-40E,MV055F1CAX50E,MV155F1CBX7E,A155C1DORO-65E,JCI-10E,BBU,A055C1DORO-65E,A055C1DORO-300E,225-007-937,AB,AD,JCL-B-5R,AM,ECL055-500E,A055B3DORO-750E,38ADMNA10E,38CAV4E,BBU27-10E,5.5AMWNA,JCR-B-12R,36TFQSJ(AMP),JCG-2R,FL11T80,JCY-15E,JCG-30,BBU27-10K,MV155F1CBX5E,3.6WKFHO,MV055F1DAX10E,BBU38-65SE,JCU-50E,JCL-B-9R,A055X900E-4,3.6ADOSJ(AMP),12OHFMA80/04,JCX-400X,JCY-/2E,JCG-3R,A155C3DORO-250E,7.2AMWNA4.0E,5.5ABWNA,5.5CAV,BBU38-30SE,A055C1DORO-20E,BBU17-20SE,JCX-12E,3.6WFLSJ(AMP),JCL-B-30,JCL-B-2R,3.6WFOSJ(AMP),JCG-4R,MV055F1CAX30E,A155C1DORO-20E,ECL055-65E,MV155F1DBX80E,5.5AMWNA*,38CAV(H)1E*,3.6ADOSJ,12OEFMA63,FL3K200,JCG-5R,7.2AMWNA2.0E,FL3T8,FL3T3,FL3T6,FL3T5,7.2OHGMA140,BBU38-3K,FL3T2,ECL055-40E,JCX-10E,BBU38-50SE,12OEFMA25/01,FL3T1,12TKLEJ,A055C1DORO-125E,JDZ-80E,JCL-B-4R,12OEFMA50,BBU27-30E,BBU27-30K,JCG-6R,BBU17-100E,JCU-300E,3.6ADLSJ(AMP),BBU17-100K,A055C1DORO-100E,MV055F1DAX30E,MV055,JCL-B-3R,MV055F1CAX10E,HVA,JCK-A-24R,HVB,36TFQSJ,BBU17-125E,HVJ,JCZ-15E,7.2OHGMA125,HVL,15.5CAV(H)1E,FL11T20,HVR,HVU,HVT,HVW,A155C1DORO-80E,HVX,MV055F2DAX300E,3.6WDLSJ,A055C1DORO-25E,FL3T200,17.5TDLSJ(AMP)*,BBU38-80K,JCT-1E,12OEFMA25,15.5CAV(H)1E*,BBU27-40SE,FL11T25,5.5AMWNA3.0E,JCK-12R,FL11T12,12OEFMA40,FL11T10,JCY-10E,MV155F1CBX15E,FL11T200,JCG-9R,ECL055,JCX-30E,3.6CAV,JCI-3E,FL11T15,24THMEJ(AMP),12TXLEJ,JCK-B-24R,A055X750E-4,7.2AMWNA0.5E,BBU38-200SE,BBU27-175SE,BBU17-150SE,JCL-18R,JCT-3E,12OEFMA01,12OEFMA03,JCH-12R,BBU17-30K,MV155F1DCX80E,BBU17-30E,BBU38-80E,JCI-5E,7.2OHGMA160,15.5CAV(H)2E,12THLEJ(AMP),FL11T65,BBU27-12K,ECL055-80E,ECL155-150E,ECL055-150E,JCT-5E,ECL055-900E,BBU27-13E,FL11T50,JCX-50E,FL11K200,BBU17-40SE,7.2WFNHO,MV155F1CBX10E,EEI-NEMA,JCK-2R,FL11T40,FL3K6,FL3K8,FL3K3,FL3K2,FL3K5,15.5CAV,FL3K1,3.6WDFHO,24TXMEJ,BBU38-100SE,JCI-12E,5.5AMWNA5.0E,JCK-3R,BBU17-50K,FL11T30,BBU17-50E,BBU27-15K,15.5OLGMA100*,JCK-18R,7.2CAV,12OEFMA63/—,3.6OEGMA,MV055F1DAX15E,5.5VKNHA,17.5TDMEJ,BBU27-15E,5.5CAV15E,BBU38-65E,A055C2DORO-600E,3.6WFFHO,BBU17-15K,BBU38-65K,15.5OLGMA,BBU17-15E,3.6OEFMA80,JCL-2R,JCT-12E,JCL-A-12R,3.6OEFMA160,JCZ-65E,MV155F2DCX125E,BBU27-100SE,FL11K80,JCU-15E,JCW-1E,36ABGNA,BBU17-7E,JCL-3R,FL11K65,17.5TKMEJ(AMP),BBU17-13E,3.6WFLSJ,MV055F2DAX350E,JCZ-40E,BBU27-20SE,JCW-2E,7.2OHGMA160*,BBU38-175E,JCL-4R,BBU38-40E,5.5AMWNA1.0E,BBU17-8K,JCR-B-9R,BBU38-40K,36CAVH,FL11K50,JCX-80E,JCX-250E,FL11K100,MV155F1DBX100E,JCL-B-18R,12OEFMA31.5/02,JCW-3E,JCU-250E,JCW-5E,JCH-18R,17.5TKMEJ,JCR-B-6R,JCL-5R,JCL-24R,JCT-1-1,15.5ABFNA,3.6OEFMA125,BBU27-200SE,BBU17-12K,JCL-6R,17.5TFLSJ,12OLGMA125,JCK-B-9R,38CAV(H)1E,JCL-B-12R,OEFMA,JCR-B-4R,36TDQSJ(AMP),MV155F1DBX15E,ECL155-40E,MV155F2DBX175E,38CAV(H)2E,BBU27-125E,BBU38-25SE,BBU38-20E,JCT-10E,JCR-B-5R,12ABCNA,BBU17-10K,BBU17-10E,7.2ABWNA,ECL155-65E,JCG-12R,JCK-B-6R,12OHGMA05,BBU38-20K,MV155F2DBX150E,FL11K140,BBU27-100K,BBU27-100E,JCY-1E,JCY-3E,JCR-B-2R,JCR-A-18R,JCL-9R,7.2TDLSJ,ECL055-200E,BBU27-5E,JCK-B-5R,12OEFMA50/03,JCD-12E,A155C1DORO-100E,BBU38-25E,3.6OLGMA,JCY-2E,JCR-B-3R,3.6OLGMA250,JCW-1⁄2E,JCX-450X,36TXQEJ(AMP)*,JCG-A-18R,BBU27-6K,JCK-B-4R,JCZ-80E,A155C3DORO-200E,ECL055-20E,JCQ-11⁄2E,JDZ-30E,3.6ABWNA,JCY-5E,BBU27-3K,BBU27-50E,MV155F2DBX200E,JCK-B-3R,JCX-125E,ECL155-20E,FL12K8,BBU27-50K,JCU-10E,3.6ADLSJ,JCK-A,A155C1DORO-15E,JCK-B,JCX-100E,MV055F1DAX50E,3.6OEFMA100,BBU38-175SE,JCK-B-2R,MV155F1DBX10E,15.5CAV(H)0.5E,ECL,JCK-B-30,JCU-125E,5.5ABWNA*,5.5ABWNA0.5E,3.6WDOH6,BBU17-5E,JCY-7E,FL11K40,JCU-100E,JCT-1-1⁄2E,17.5OHGMA,MV055F1CAX15E,JCR-B-18R,ECL055-25E,JCZ-200E,BBU17-6K,ECL155-300E,ECL055-750E,FL11K30,17.5TDMEJ(AMP),JCI-1⁄2E,JCU-450E,MV055F1DAX125E,36TDQSJ,3.6WFOH6,CAV,JCK-A-18R,JDZ-50E,12OHFMA,A3354710,5.5CAVH2E,BBU17-140K,FL11K25,BBU17-3K,FL11K20,BBU27-7E,ECL055-400E,3.6OEFMA63,BBU38-200E,JCU-30E,MV055F1DAX100E,MV155F1DBX30E,JCR-A-12R,BBU38-200K,5.5CAVH1E,JCX-15E,BBU17-15SE,7.2OEFMA,JCL-A-18R,FL11K15,A055C1DORO-150E,ECL155-25E,FL11K12,BBU27-8K,FL11K10,BBU27-140K,15.5OLGMA100,17.5TDLSJ,BBU27-15SE,JCW-12E,BBU17-125SE,A3354730,BBU27-20E,BBU27-20K,12OHGMA100/—,A055C2DORO-450E,JCK-B-18R,24TDMEJ(AMP),JCX-300E,JCQ-2E,A155C2DORO-125E,15.5CAV(H)0.5E*,JCX-25E,12OHGMA100,JCX-325X,ECL155-15E,MV155,A3354745,BBU17-65SE,JCZ-150E,MV055F1DAX25E,JCQ-3E,JCL-A-9R,JCD-1⁄2E,7.2TFLSJ,JCR-B-24R,ECL155-125E,7.2WKMSJ,A055C1DORO-30E,MV055F1CAX40E,A155C1DORO-30E,12OLGMA125*/—,MV055F1CAX65E,MV155F1DBX50E,BBU17-80K,ECL155-100E,JCU-400E,ECL055-50E,JCQ-5E,FL3K140,A055C1DORO-200E,JCT-1-2E,JCL-A-5R,BBU27-40E,JCY-25E,ECL055-600E,BBU27-40K,15.5OHGMA,JCU-80E,MV155F2DCX150E,12OEFMA31.5,JCU-750E,36CAV,12OEFMA,MV055F1DAX20E,12OHFMA04,BBU27-65E,38ADMNA7E,JCH-30,JCL-A-4R,JCH-2R,BBU17-80E,BBU27-65K,BBU17-200E,A155C1DORO-10E,MV055F1CAX20E,BBU27-50SE,BBU17-200K,7.2WKMSJ(AMP),JCQ-/2E,JCH-3R,A055C1DORO-50E,7.2AMWNA3.0E,7.2OHGMA,BBU27-150SE,3.6WDOSJ,BBU38-40SE,38CAV(H)2E*,15.5CAVH*,FL3T140,JCL-A-6R,JCH-4R,FL3K100,MV055F1DAX150E,24CAV,38CAV(H)0.5E,ECL055-30E,JCX-20E,MV055F1DAX175E,JCK-A-12R,JCH-5R,7.2AMWNA1.0E,JCX-65E,3.6WFOSJ,FL3T50,3.
Vicfuse(威可特)跌落式熔断器选型指南
描述- Vicfuse`s medium voltage drop-out fuses are customers' preferred outdoor high voltage overhead 10kV~40.5kV to provide a full range of fault protection for transformers, capacitors, cables or overhead line segment points and branch lines in the distribution system. 威可特跌落式熔断器是客户优选的户外高压架空10kV~40.5kV对配电系统中的变压器、电容器、电缆或架空线路分段点和分支线路提供全范围的故障保护,从最小的熔断电流到最大开断电流均能按照准确的时间-电流特性,提供可靠的过载和短路保护。
型号- 12VASL100HWF,24VASL100CW,12VASL100CW,12VASL200HW,V38025R/F,V38040R/F,24VASL200CW,12VASL100CWF,V38008R/F,V38200R/F,V38006R/F,38VASL100CPWG,V38030R/F,12VASL200CW,12VASL50CPW,V38080R/F,24VASL200HW,10VASLCW,38VASL*CXW,VXXXXXXXX,10VASL*CXW,V38015R/F,12VASL100HW,V38020R/F,24VASL100CWF,38VASL200HPWG,24VASL100HW,12VASL200CWF,V38001R/F,38VASLCW,V38003R/F,12VASL200HWF,24VASL100HWF,□VASL□□□□□□□□□,V38140R/F,24VASL200HWF,V38005R/F,V38060R/F,12VASL100CPW,V38050R/F,38VASL100HPWG,V38012R/F,38VASL200CPWG,V38010R/F,24VASL200CWF
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
Explanation of Parameters in the PPTC Specification for Self Healing Fuses
This is very simple. As long as you know the meaning represented by the parameters in the specification book, you can clearly and quickly view the PTC specification book for self recovery fuses.
Selection of Current Fuses in Automotive Circuits
In automotive circuits, the selection of current fuses is of great significance for ensuring the safe operation of the vehicle. There are several key factors to consider when choosing a current fuse for an automotive circuit.
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
Essential Knowledge for Selecting Automotive Fuses
When a certain overload current passes through, the heat generated is radiated to the surrounding environment through the melt and shell, and the heat dissipated through convection, conduction, and other means gradually reaches a balance with the heat generated. If the generated heat is greater than the dissipated heat, the melt temperature can increase; When the temperature reaches or exceeds the melting point of the melt, the melt melts, fuses, and cuts off the current, playing a role in safety protection of the circuit.
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
Electric Vehicle Malfunctions Due to Lack of Fuses or Diodes
With the development of life, electric vehicles have also become popular. In order to facilitate people‘s travel, many families have started to use electric vehicles, which are convenient and affordable. However, there are still many unknown problems that arise during use. Today, the editor will briefly talk about the structural issues of electric vehicles.
The Role of Current Fuses in Smart Meters
Current fuses play a vital role in smart meters. Firstly, they provide protection against overcurrent events. Smart meters are used to measure and manage electricity consumption accurately. However, electrical circuits can sometimes experience sudden surges in current due to various reasons such as power outages and subsequent restoration, short circuits in the electrical grid, or the malfunction of connected electrical appliances.