How to Select Low Voltage Fuses with Chip Mounts
Chip low-voltage fuse is a type of fuse, abbreviated as Low Voltage Fuses with Chip Mounts. The function of a low-voltage fuse is to provide short circuit protection in the circuit. Its advantages include high breaking capacity, strong reliability, small installation area, convenient maintenance, and low price. The disadvantage is that there are few protection methods and the recovery time of the power supply is long.
How to Select Low Voltage Fuses with Chip Mounts
Commonly used low-voltage fuses include various types such as porcelain plug type, sealed tube type, spiral type, filler type, and so on. The ceramic plug type has poor arc extinguishing ability and is only suitable for use at the end of lines with small fault currents. Other types of fuses have arc extinguishing measures, with strong current breaking ability. The closed tube structure is simple, and the spiral type is safer when replacing the fuse tube. The filling material type has a stronger current-breaking ability.
Low voltage fuses are divided into plug-in, spiral, unfilled, and filled types according to their structural forms. According to the range of breaking current, it can be divided into full-range segmented capacity and partial-range breaking capacity. According to the category of use, it can be divided into: general purpose and protection of electric motors.
When selecting patch low-voltage fuses, we need to determine the type of fuse based on the usage conditions. When selecting fuse specifications, we should first select the specification of the melt, then select the specification of the fuse based on the melt, and then have a good coordination between the protection characteristics of the fuse and the overload characteristics of the protected object.
Fig.1
- |
- +1 赞 0
- 收藏
- 评论 0
本文由三年不鸣转载自XC News,原文标题为:battery charger fuse size.How to Select Low Voltage Fuses with Chip Mounts,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
设计经验 发布时间 : 2023-11-24
The Installation Precautions for Current Fuses
The installation of current fuses is crucial for ensuring the safety and proper functioning of electrical circuits. Here are some important installation precautions to keep in mind.
设计经验 发布时间 : 2024-11-04
Solution to Fuse Failure
XC shares about Solution to Fuse Failure.
设计经验 发布时间 : 2023-12-29
旭程(XC)保险丝选型指南
目录- Company Profile Fuse User's Manual Fuse Auto Fuse Fuse Holder Thermostat
型号- 06F,3S,C0015302Z,C0040302Z,3T,10C,06T,C0060303Z,4F,KSD9700,C0030301Z,6CH,C7500301Z,4T,C0015301Z,C0070303Z,4TE,C0040303Z,8TE,C0025302Z,5C,KSD305,5F,5G,C4000302Z,5H,9L,KSD301,C2000302Z,C0030302Z,10FV,C0020301Z,5S,C7500302Z,5T,C0010302Z,24F,12F,32F,C0080303Z,5SH,6B,6C,C0025301Z,6F,6G,24T,6H,12T,C3000301Z,C4000301Z,C5000301Z,2F,C2000301Z,C0030303Z,32T,R3-13,5GH,R3-12,R3-11,5CH,6S,C0020302Z,6T,2T,5TE,XC-1,BS1362,C0010301Z,C3000302Z,5TR,3F,3G,C5000302Z,C1000302Z,XC-2,C0050303Z,C0035302Z,C0020303Z
The Impact of Fuse Aging on Usage
After the fuse ages, there is no danger of generating the current that should be cut off and the fuse not blowing. The aging of a fuse is equivalent to a decrease in the rated value (current) rather than an increase, resulting in the circuit being cut off at a small overload current or pulse.
技术探讨 发布时间 : 2023-12-16
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
技术探讨 发布时间 : 2024-11-13
High-Voltage Connector Systems AUTOMOTIVE
目录- Company profile High-Voltage Connectors HV Contact Systems and Connection Technologies HVR®50 connectors HVR®200 connectors HVR®260 connectors HVR®300 connectors HVR®420 connectors HPK connectors DCS connectors HV Fuse HV Components LVR®120 connectors High-Voltage Connnectors Part Number index
型号- H4K135-W10035B1-YY,HAK203-W10120B1-Y,H4K137-W10035B1-YY,H4K137-W20016B1-YYY,H2K101-W2AXXXB1-Y,H4K136-W10035B1-YY,H4K135-W20016B1-YYY,H4K208-W2U050B1-YYY,H6K106-12A004B1-Y,H4K134-W10035B1-YY,H9K106-51-070B-Y,H9S105-W1F050B1-Y,H4K210-W2U050B1-YYY,HKS112-22-000B1-Y,H5K203-92-000X1-Y,H1S103-92SLF0B1-Y,H2K101-W2A016B1-Y,H2S104-02-000B1-Y,H4K137-W20025B1-YYY,H5S102-920016X1-Y,170-101-00000,H4K137-W10025B1-YY,HKK204-W20070B1-Y,H4K136-W20025B1-YYY,H4S115-92-H00B-Y,H4K135-W20025B1-YYY,H4K134-W10025B1-YY,H4K209-W2U035B1-YYY,H4K134-W20025B1-YYY,H2S207-02-000B1-Y,H4K135-W10025B1-YY,H4K208-W2U035B1-YYY,H4K136-W10025B1-YY,H4CK10A-110,H4K136-W20050B1-YYY,H4K135-W20050B1-YYY,H6L106-5B-001B1-Y,H4K134-W20050B1-YYY,H4S115-92-H00B-YY,HKS110-22-000B1-Y,HAS103-21-000B1-Y,H9S109-11F035B1-Y,H4CK10B-110,H4S115-91-000B-Y,H4K137-W20050B1-YYY,HAS105-21-000B1-Y,H2K101-W2A035B1-Y,H4K210-W2U035B1-Y,H4K136-W20016B1-YYY,HAK203-W10095B1-Y,H4K134-W10016B1-YY,H4K215-W1U050B1-YY,H6K206-12A004B1-Y,H4K134-W20016B1-YYY,HKS109-22-000B1-Y,H1K103-92SLF0B1-Y,H4K137-W10016B1-YY,H4K136-W10016B1-YY,H4K209-W2U050B1-YYY,H4K135-W10016B1-YY,H4K210-W2U035B1-YYY,H9K106-51-050/90B,H4S115-92-000B-YY,H6K105-12A006B-Y,H4K136-W10050B1-YY,H4S115-91-H00B-Y,H4K134-W10050B1-YY,H6K205-12A006B-Y,H6K206-12A006B1-Y,H4K136-W20035B1-YYY,H4K137-W10050B1-YY,H4K134-W20035B1-YYY,H4K135-W20035B1-YYY,H6K207-12A006-B1-Y,H4K208-W2U025B1-YYY,H6K106-12A006B1-Y,HKS113-22-000B1-Y,H4K209-W2U025B1-YYY,HAK203-W10035B1-Y,H6L106-5C-001B1-Y,H9K105-51-050/80-Y,H6K107-12A006B1-Y,HAK203-W10070B1-Y,H4S115-92-000B-Y,H9S105-W1F035B1-Y,H4K137-W20035B1-YYY,170-099-00005,H4K215-W1U035B1-YY,H9S105-W1F070B1-Y,H4K135-W10050B1-YY
Several Factors Influence the Lifetime of Current Fuses
The lifetime of a current fuse is influenced by several factors. Firstly, the current rating of the fuse plays a crucial role. If a fuse is constantly operating near or at its rated current, it will experience more heat buildup and stress over time, which can shorten its lifetime.
技术探讨 发布时间 : 2024-11-06
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
技术探讨 发布时间 : 2023-11-30
SMD fuse and Chip Fuse Specifications
SMD fuses can be divided into SMD disposable fuses and SMD self recovery fuses. Among them, the specifications of patch disposable fuses include series 060312062410 fuses, and the specifications and dimensions of patch self recovery fuses include series 0603, 0805, 1206, 1210, 1812, 2920, etc.
技术探讨 发布时间 : 2023-12-04
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
技术探讨 发布时间 : 2023-12-15
Guide to Current Fuse Selection
Selecting the appropriate current fuse is crucial for the safety and efficient operation of an electrical system. Firstly, one must consider the rated current of the circuit. The rated current of the fuse should be slightly higher than the normal operating current of the circuit. For example, if a circuit typically operates at 5 amperes, a fuse with a rated current of around 5 - 7 amperes might be suitable. However, it should not be too high, as this may lead to a situation where the fuse does not blow when it should during an overload or short - circuit.
器件选型 发布时间 : 2024-10-16
5TE 系列 12A/300方型塑胶保险丝(环保产品) 产品承认书(5TE SERIES 12A/300V 5TE SUB-MINIATURE FUSE-LINK(GREEN PRODUCT) SPECIFICATION FOR APPROVAL)
型号- 5TE,5TE SERIES,5TE 系列,011.212060001
Classification of Fuses
Fuses are divided into two categories: high voltage and low voltage. High voltage fuses for 3kV-35kV; Low voltage fuses are used for AC 220V, 380V, and DC 220V, 440V.
技术探讨 发布时间 : 2023-11-30
Low Voltage Fuses: Essential Protective Components in Low-Voltage Circuits
Low voltage fuses play a crucial protective role in power systems and electronic devices. It has a fast response speed and can instantly cut off excessive current to prevent the fault from expanding. It also has good reliability and stability.
技术探讨 发布时间 : 2024-10-09
电子商城
现货市场
服务
可贴片PCB尺寸50*50mm-580*610mm;PCB厚度0.3-8mm;贴装精度CHIP元件+0.03,BGA Pitch 大于0.25mm;元件尺寸0201-74*74BGA;元件高度:30mm。
最小起订量: 1 提交需求>
可加工PCB的尺寸范围:50*50mm~610*508mm,板厚:0.3mm~4.5mm,元件尺寸:最大200*125mm,最小引脚零件间距:0.3mm,最小BGA间距:0.3mm,支持01005 chip件贴装。
最小起订量: 3 提交需求>
登录 | 立即注册
提交评论