Discussion on the Application of Fuses on LED Beads
1、 Firstly, analyze the causes of LED bead damage, which are usually caused by the following reasons
① A sudden increase in power supply voltage.
② The temperature inside the lamp is too high
③ Short circuit in the circuit.
④ Failure to do a good job in preventing static electricity during assembly has caused damage to the interior of the LED lamp beads due to static electricity. Although normal voltage and current values are applied, it is extremely easy to cause damage to LED beads
⑤ The voltage and current of the circuit are unstable.
2、 How to protect the circuit of LED beads?
Answer: Nowadays, many circuits use Fuses for overload protection, but disposable fuses are not suitable for LED lamp products because the circuits of LED beads are very different from those of other products. LED bead circuit overload is caused by the overload protection component, which immediately disconnects the LED bead circuit and automatically restores power supply after the circuit is normal, without affecting LED operation. Moreover, the circuit should not be too complex, bulky, and cost-effective, making it difficult to achieve a one-time fuse.
3、 To solve the overload problem of LED bead circuits, there are two ways to start
1. Select self recovery fuse
① Shunt protection. Generally, LED lights are divided into many series connected branches. We can add a PTC component in front of each branch for protection. The advantages of this method are high accuracy and good reliability of protection.
② Overall protection. Add a PTC component in front of all light beads to protect the entire lamp. The advantage of this method is that it is simple and does not take up volume. For civilian products, the results of this protection in practical use are still satisfactory.
2. Using Transient Voltage Suppression Diodes (TVS)
Transient voltage suppression diode is a high-efficiency protective device in the form of a diode. When its poles are subjected to reverse transient high-energy shocks, it can immediately reduce the high resistance between its poles to low resistance at a speed of 10 to the negative 12th power second, absorbing up to several kilowatts of surge power, clamping the voltage between the poles at a predetermined voltage value, effectively protecting precision components in electronic circuits. Transient voltage suppression diodes have the advantages of fast response time, high transient power, low leakage current, good consistency of breakdown voltage deviation, easy control of clamping voltage, no damage limit, and small volume.
Fig.1
- |
- +1 赞 0
- 收藏
- 评论 0
本文由三年不鸣转载自XC News,原文标题为:plastic fuse box under stairs.Discussion on the Application of Fuses on LED Beads,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Which is Better, LED Lamp Beads and SMD SMD LEDs?
From the packaging volume points: 3528, 2835, 3535, 5050, 5630, and so on. It is widely used in lighting fixtures. The processing method is generally: reflow soldering. (Divided into low temperature welding, low temperature welding, high temperature welding) In addition, the gap of the chip LED is generally negative. (Depending on the packaging method, it will change.) SMD lamp beads are cheap and can be mass-produced; high-power lamp beads have high brightness, long life and convenient DIY.
Factors Affecting the Lifespan of Fuses and Their Evaluation
In this article, XC tells factors that affect the lifespan of fuses.
Explanation of Parameters in the PPTC Specification for Self Healing Fuses
This is very simple. As long as you know the meaning represented by the parameters in the specification book, you can clearly and quickly view the PTC specification book for self recovery fuses.
旭程(XC)温控器选型指南
目录- 公司介绍 Company Profile 温控器 Thermostat 保险丝 Fuses 企业资质与专利 Qualification and Patents Certifications
型号- C0015302Z,9K7.SK-B5,KSD305系列,9K7.SK-B3,CG-B,CG-A,SK-B1系列,9K7CG-XXX,SK-B5系列,KSD301系列,KSD307B,SK-A1,KSD307 SERIES,SK-A4,C0015301Z,9K7.SK-C2,SK-C2系列,C0025302Z,C4000302Z,KT SERIES,9K7.JW-A072,C2000302Z,CG-B系列,C0080303Z,9K7.SK-B11,JW-C系列,KSD305B,JW,KSD305-XXXX/XXXX,SK-C2,9K7SK-XXXX/XXXXX,C4000301Z,C5000301Z,SK,CG SERIES,9K4307-XXXX/XXXX,C0020302Z,CG,KT,KSD9700 SERIES,SK-B1,C5000302Z,C1000302Z,C0050303Z,SK-B5,C0035302Z,C0020303Z,C0040302Z,KSD307系列,KSD301-XXX/XXXXXX/XXX,9K7KT-XXXX/XXXXX,9K7.SK-F3,SK-F5系列,JW-B系列,C0060303Z,KSD9700,C0030301Z,KT系列,C7500301Z,C0070303Z,C0040303Z,SK-A1系列,9K9.9700-XXXXXXX,KSD305,KSD307,KT-A2,KT-A1,KSD301,C0030302Z,JW SERIES,JW系列,C0020301Z,C7500302Z,C0010302Z,9K4.307B,JW-A系列,CG-A1,C0025301Z,CG系列,KSD9700系列,C3000301Z,C2000301Z,C0030303Z,KT-A系列,SK SERIES,JW-B,JW-C,SK系列,KSD301 SERIES,KSD305 SERIES,CG-B2,C0010301Z,SK-F5,C3000302Z,SK-F6,9K7JW-XXXX,CG-A系列,KSD307-XXXX/XXXX,KT-A,9K4.307
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
Temperature Characteristics of Current Fuses
Current fuses exhibit specific temperature characteristics that play a crucial role in their performance and reliability. The behavior of a current fuse in response to temperature changes is determined by several factors.
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
Selection of Current Fuses in Automotive Circuits
In automotive circuits, the selection of current fuses is of great significance for ensuring the safe operation of the vehicle. There are several key factors to consider when choosing a current fuse for an automotive circuit.
Electric Vehicle Malfunctions Due to Lack of Fuses or Diodes
With the development of life, electric vehicles have also become popular. In order to facilitate people‘s travel, many families have started to use electric vehicles, which are convenient and affordable. However, there are still many unknown problems that arise during use. Today, the editor will briefly talk about the structural issues of electric vehicles.
Essential Knowledge for Selecting Automotive Fuses
When a certain overload current passes through, the heat generated is radiated to the surrounding environment through the melt and shell, and the heat dissipated through convection, conduction, and other means gradually reaches a balance with the heat generated. If the generated heat is greater than the dissipated heat, the melt temperature can increase; When the temperature reaches or exceeds the melting point of the melt, the melt melts, fuses, and cuts off the current, playing a role in safety protection of the circuit.
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
The Installation Precautions for Current Fuses
The installation of current fuses is crucial for ensuring the safety and proper functioning of electrical circuits. Here are some important installation precautions to keep in mind.
What is A Self Recovery Fuse
Self recovery fuse is an overcurrent electronic protection component that uses a polymer organic polymer under high pressure, high temperature, and sulfurization reaction conditions.After mixing with conductive particle materials, it is processed through a special process. Habitually applying PPTC (Polymer Positive Temperature).
The Role of Current Fuses in Smart Meters
Current fuses play a vital role in smart meters. Firstly, they provide protection against overcurrent events. Smart meters are used to measure and manage electricity consumption accurately. However, electrical circuits can sometimes experience sudden surges in current due to various reasons such as power outages and subsequent restoration, short circuits in the electrical grid, or the malfunction of connected electrical appliances.
电子商城
现货市场
服务
配备KEYSIGHT网络分析仪,可测量无线充电系统发射机/接收机线圈的阻抗,电感L、电阻R、电感C以及品质因数Q,仿真不同充电负载阻抗下的无线充电传输效率。支持到场/视频直播测试,资深专家全程指导。
实验室地址: 深圳 提交需求>
登录 | 立即注册
提交评论