Selection Process of Fuses
Selection Process of fuses:
1. Safety certification: Determine the safety certification of fuses based on the required safety certification for the entire machine, such as UL or IEC specifications.
2. Structural size: The size is determined based on the space in the circuit design, such as length, diameter, and whether there are leads.
3. Rated voltage: It must be greater than or equal to the actual application voltage, generally including 24V, 32V, 63V, 125V, 250V, etc.
4. Breaking capacity: should be greater than the maximum fault current in the circuit.
5. Rated current: Based on the following items:
(1) Normal working current, the rated current of UL specification fuses operating at 25℃ is ≥ normal working current/0.75; The rated current of IEC standard fuses is ≥ normal working current/0.9.
(2) Environmental temperature: The current carrying capacity test of a fuse is conducted under the ambient temperature of 25℃. The higher the ambient temperature, the shorter the lifespan of the fuse, and the lower the carrying capacity. Therefore, when selecting a fuse, environmental temperature should be considered.
(3) Pulse: Pulse generates thermal cycling and mechanical fatigue that affects the lifespan of the fuse. When designing, the pulse I2T should be smaller than the nominal melting heat energy of the fuse, taking into account the pulse factor. The rated I2T of the fuse is greater than the actual pulse I2T/Pf Pf: The pulse factor varies depending on the number of pulses it can withstand, as shown in the following figure:
6. The samples selected through the above procedures need to be tested in actual circuits to verify the suitability of the selected fuse. This verification should include testing under normal and fault conditions to ensure that the selected fuse plays a protective role in the protected circuit.
Fig.1
- |
- +1 赞 0
- 收藏
- 评论 0
本文由三年不鸣转载自XC News,原文标题为:Selection process of fuses.outboard motor thermostat stuck open,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
The Installation Precautions for Current Fuses
The installation of current fuses is crucial for ensuring the safety and proper functioning of electrical circuits. Here are some important installation precautions to keep in mind.
Why Do Fuses Have High Resistivity
A fuse is a wire made of lead antimony alloy with a lower melting point and a lower resistivity. The more voltage constant resistance can be compared, the more it can detect micro current resistance that exceeds the working range. A high current is required to fuse the resistance, which can burn out the electrical appliance and prevent it from melting. Some principles use the current thermal effect fuse to control the current flow and allow the current to flow.
旭程(XC)温控器选型指南
目录- 公司介绍 Company Profile 温控器 Thermostat 保险丝 Fuses 企业资质与专利 Qualification and Patents Certifications
型号- C0015302Z,9K7.SK-B5,KSD305系列,9K7.SK-B3,CG-B,CG-A,SK-B1系列,9K7CG-XXX,SK-B5系列,KSD301系列,KSD307B,SK-A1,KSD307 SERIES,SK-A4,C0015301Z,9K7.SK-C2,SK-C2系列,C0025302Z,C4000302Z,KT SERIES,9K7.JW-A072,C2000302Z,CG-B系列,C0080303Z,9K7.SK-B11,JW-C系列,KSD305B,JW,KSD305-XXXX/XXXX,SK-C2,9K7SK-XXXX/XXXXX,C4000301Z,C5000301Z,SK,CG SERIES,9K4307-XXXX/XXXX,C0020302Z,CG,KT,KSD9700 SERIES,SK-B1,C5000302Z,C1000302Z,C0050303Z,SK-B5,C0035302Z,C0020303Z,C0040302Z,KSD307系列,KSD301-XXX/XXXXXX/XXX,9K7KT-XXXX/XXXXX,9K7.SK-F3,SK-F5系列,JW-B系列,C0060303Z,KSD9700,C0030301Z,KT系列,C7500301Z,C0070303Z,C0040303Z,SK-A1系列,9K9.9700-XXXXXXX,KSD305,KSD307,KT-A2,KT-A1,KSD301,C0030302Z,JW SERIES,JW系列,C0020301Z,C7500302Z,C0010302Z,9K4.307B,JW-A系列,CG-A1,C0025301Z,CG系列,KSD9700系列,C3000301Z,C2000301Z,C0030303Z,KT-A系列,SK SERIES,JW-B,JW-C,SK系列,KSD301 SERIES,KSD305 SERIES,CG-B2,C0010301Z,SK-F5,C3000302Z,SK-F6,9K7JW-XXXX,CG-A系列,KSD307-XXXX/XXXX,KT-A,9K4.307
Temperature Characteristics of Current Fuses
Current fuses exhibit specific temperature characteristics that play a crucial role in their performance and reliability. The behavior of a current fuse in response to temperature changes is determined by several factors.
Factors Affecting the Lifespan of Fuses and Their Evaluation
In this article, XC tells factors that affect the lifespan of fuses.
Explanation of Parameters in the PPTC Specification for Self Healing Fuses
This is very simple. As long as you know the meaning represented by the parameters in the specification book, you can clearly and quickly view the PTC specification book for self recovery fuses.
Selection of Current Fuses in Automotive Circuits
In automotive circuits, the selection of current fuses is of great significance for ensuring the safe operation of the vehicle. There are several key factors to consider when choosing a current fuse for an automotive circuit.
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
Essential Knowledge for Selecting Automotive Fuses
When a certain overload current passes through, the heat generated is radiated to the surrounding environment through the melt and shell, and the heat dissipated through convection, conduction, and other means gradually reaches a balance with the heat generated. If the generated heat is greater than the dissipated heat, the melt temperature can increase; When the temperature reaches or exceeds the melting point of the melt, the melt melts, fuses, and cuts off the current, playing a role in safety protection of the circuit.
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
Electric Vehicle Malfunctions Due to Lack of Fuses or Diodes
With the development of life, electric vehicles have also become popular. In order to facilitate people‘s travel, many families have started to use electric vehicles, which are convenient and affordable. However, there are still many unknown problems that arise during use. Today, the editor will briefly talk about the structural issues of electric vehicles.
The Role of Current Fuses in Smart Meters
Current fuses play a vital role in smart meters. Firstly, they provide protection against overcurrent events. Smart meters are used to measure and manage electricity consumption accurately. However, electrical circuits can sometimes experience sudden surges in current due to various reasons such as power outages and subsequent restoration, short circuits in the electrical grid, or the malfunction of connected electrical appliances.
Common Sense for Fuses
A fuse refers to a self destructing fuse that experiences significant surges or other current exceeding limits in a circuit; In order to protect the components of other parts of the circuit where the fuse is located and the equipment is normal, the cost of replacing the fuse can be ignored compared to replacing the entire circuit that may be damaged. Due to the fact that fuses are a common element that needs to be replaced, we will introduce two basic concepts and provide a more in-depth introduction to fusion applications and testing and diagnostic methods.
电子商城
现货市场
登录 | 立即注册
提交评论