Wireless Module Electrical Performance Test Report:All Technical Indicators Have Reached the Standard Requirements
In order to better guarantee the product quality of Wireless modules, G-NiceRF sends the wireless modules it produces to the laboratory for inspection and testing. The inspection items include safety testing, climate and environmental testing, electromagnetic compatibility testing, etc. The specific test values of various technical indicators are as follows.
1. Electrostatic discharge test
Contact discharge: test method and standard requirements: the tested sample is in normal working condition, and the metal surface of the tested sample (select 4 sensitive points) is used for contact discharge with an electrostatic discharge instrument. Discharge voltage: 4kV, each sensitive Pointing is performed 20 times (10 times for positive and negative polarity), with an interval of 1S each time. Should meet performance criterion B.
Test result: meet the requirements
Air discharge: test methods and standard requirements: the tested sample is in normal working condition, and the non-metallic surface (including holes, seams, etc.) of the tested sample is air discharged with an electrostatic discharge instrument. The discharge voltage: 8kV, each Pointing is performed 20 times (10 times for positive and negative polarity), with an interval of 1S each time. Should meet performance criterion B.
Test result: meet the requirements
Connection diagram of electrostatic discharge test layout:
2. Radio frequency continuous wave conduction test
Test method and standard requirements: The sample under test is in normal working condition, and 80℅AM (1kHz) sinusoidal modulation signal is applied to the AC power terminal and signal terminal, the test voltage is 3V, and the frequency range is 0.15-80MHz. Should meet performance criterion A.
Inspection result: meet the requirements
Connection diagram of radio frequency continuous wave conduction test layout:
3. Radio frequency electromagnetic field test
Test method and standard requirements: The sample under test is in normal working condition, and 80℅AM (1kHz) sinusoidal modulation signal is applied to the AC power terminal and signal terminal, the test field strength is 10V/m, and the frequency range is 80-1000MHz. Should meet performance criterion A.
Inspection result: meet the requirements
Connection diagram of radio frequency electromagnetic field test arrangement:
4. Electrical fast transient test
Power supply terminal: The test sample is in normal working condition, and the transient pulse generator is used to apply a pulse group of voltage 1.0kV and frequency of 5kHz to the AC power supply terminal of the test sample. , Application time: 1 time 1 minute. Should meet performance criterion B.
Signal terminal: Use the transient pulse group generator capacitive coupling clamp to apply a pulse group with a voltage of 0.5kV and a frequency of 5kHz to the signal terminal. The number of applications: positive and negative polarity 1 time, application time: 1 time 1 minute. Should meet performance criterion B.
Inspection result: meet the requirements
Electrical fast transient test layout connection diagram:
5. Voltage sag test
Detection method and requirements: The sample under test is in normal working condition, and the AC power port is input with 70% of the rated voltage with a voltage instantaneous interruption tester for 25 cycles. Should meet the performance criterion C.
Inspection result: meet the requirements
Detection method and requirements: The sample under test is in normal working condition, and the AC power port of the tester is used to input the rated voltage of <5% for 0.5 cycle. Should meet performance criterion B.
Inspection result: meet the requirements
6. Short-term voltage interruption test
Detection method and requirements: The tested sample is in normal working condition, and the AC power port of the tester is used to input a rated voltage of <5% for 250 cycles. Should meet the performance criterion C.
Inspection result: meet the requirements
Connection diagram of test arrangement for voltage sag and short-term interruption of voltage:
7. Surge test
Testing method and requirements: The test sample is in normal working condition, and the surge signal generator is used to apply the surge combined wave signal to the AC power terminal of the test sample. The number of applications: positive and negative polarity 5 times each, repetition rate: 1 Times/1 minute, applied voltage: line-line: 1kV; line-ground: 2kV. Should meet performance criterion B.
Inspection result: meet the requirements
Surge test layout connection diagram:
The above is the test report of G-NiceRF's wireless module products. All technical indicators have reached the standard requirements. Its good performance is obvious, and it is a high-quality wireless module.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由咪猫转载自G-NiceRF Official Website,原文标题为:Wireless module electrical performance test report,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
LoRa1276-C1 Wireless Module with Output Power of 100mW is Suitable for Industrial Applications, Has Obtained FCC, IC, and CE certifications
The Lora1276-C1 wireless module utilizes Semtech‘s SX1278 and excels in industrial applications due to its outstanding performance. It has obtained FCC, IC, and CE certifications.
产品 发布时间 : 2024-11-09
LoRa-STM32WLE5 SoC Wireless Module: Achieving Ultra-Long Range and Low-Power High-Performance Wireless Communication
The LoRa-STM32WLE5 module uses STMicroelectronics‘ STM32WLE5 chip, designed primarily for ultra-long-range and ultra-low-power radio solutions. The module is widely applicable in security systems, smart agriculture, industrial manufacturing, smart home solutions, and more.
产品 发布时间 : 2024-11-09
G-NiceRF Releases SA618F30 1W Long-Range Full-Duplex Wireless Audio Module, Easily Embedded Into Handheld Devices
The SA618F30 is a high-performance-to-price ratio, highly integrated high-power full-duplex walkie-talkie module. It can be easily and efficiently embedded into various handheld devices, enhancing the overall performance of the end product.
产品 发布时间 : 2024-11-05
Method to Improve the Transmission Distance of 433MHz Wireless Module
After many customers bought a 433MHz wireless module, the transmission distance of the wireless module was unsatisfactory due to the use environment, weather, and other factors. So, how should the transmission distance of the 433MHz wireless module be improved?
技术探讨 发布时间 : 2024-06-13
NiceRF‘s STX882 ASK Module is Equipped with a Data Port for Users to Directly Connect to the Microcontroller, Becomes the First Choice for Wireless Doorbells
The doorbell is a common living furniture in modern life. It can be used in high-rise buildings, high-rise houses in the city, and even our folk buildings. The doorbell has evolved from the function of calling only the guest to the transmission of portal information, gate control, alarm to the guard in an emergency, etc., all of which indicate that the doorbell continues to develop towards intelligent discovery.
应用方案 发布时间 : 2024-11-12
Wireless Module: Factors Affecting Transmission Distance
The communication distance of the wireless module is mainly divided into two parts, the first is the internal parameters and accessories of the module, and the second is the external factor.
技术探讨 发布时间 : 2024-06-11
The built-in Wireless Module of the Bicycle Smart Helmet Can Play Music
The Coros LINX bicycle smart helmet is born for cyclists. It has a built-in wireless module and can play music when connected to a mobile phone via Bluetooth.
应用方案 发布时间 : 2024-06-10
DEMO kit tutorial of LoRa module LoRa1262
Introduction to the DEMO kit of the LoRa module LoRa1262.The LoRa1262 wireless module antenna switch is integrated and controlled by the chip, which saves the resources of the external MCU.
设计经验 发布时间 : 2024-06-08
What is the Role of the Wireless Module with a Shielding Cover
The wireless module is equipped with or without shielding cover, customers can choose according to their own needs. In order to improve the anti-interference ability, it is recommended that users choose the wireless module with shielding cover.
技术探讨 发布时间 : 2024-06-12
What is a Single and Duplex Wireless Module?
Recently, there is customer consultation, what is a simplex wireless transceiver module, and what is the duplex wireless transceiver module? What is the difference between them?NiceRF here to answer this question for everyone.
技术探讨 发布时间 : 2024-06-10
Reasons and Solutions for Wireless Module Verification Failure
Wireless module often fails during the verification process. What is the reason? Most of the reasons for the verification failure are due to data loss and errors during the verification process.
技术探讨 发布时间 : 2024-06-07
电子商城
登录 | 立即注册
提交评论