What is the Reason Why the Fuse Keeps Burning Out?
Using a fuse that is too small can easily burn out and cause power outages, while using one that is too large may cause damage to electrical equipment. So for safety reasons, to ensure the "safety" of the fuse, the following points should be noted:
(1) Do not use fuses that are too thin. Using thin fuses can easily cause the normal current passing through to burn out, resulting in unnecessary power outages;
(2) Suitable fuses must be selected and used, and the melting current of fuses is usually 1.5 to 2.0 times the rated current. If the total power of all appliances in a household exceeds 1100 watts during normal electricity use, choose a 5 ampere fuse and use a 20 gauge fuse with a diameter of 0.98 millimeters. When the current exceeds 7.5 amperes to 10 amperes, the fuse will automatically melt to achieve protection;
(3) When installing fuses on power switches, live operation is not allowed. The power switch should be pulled open to disconnect the power supply;
(4) Wrap the fuse clockwise around the fastening screw and tighten the screw with a gasket until it is securely fastened. Do not apply too much force or compress the fuse too tightly; In addition, the fuse should not be pulled too tightly between the other fastening screws, and there should be a margin to prevent damage to the fuse. Normally, the power switch and fuse must not be exposed and must be covered with a rubber wooden cover to ensure safety;
(5) If the selected and used fuse meets the specifications but frequently experiences fuse melting, it indicates that there is a problem with the electrical circuit and equipment. An electrician should be promptly consulted to identify the cause and eliminate the hidden danger. Do not replace coarse fuses at will or simply replace them with copper wire, iron wire, etc.
(6) For fuse melting in daily use: The first situation is when the middle is broken but both sides are intact, which is caused by excessive load current leading to fuse melting or fuse damage, resulting in a decrease in melting point, but the current is not too high. The second situation is that when the fuse is blown, all the fuses will melt, and there will be burn marks and black and white gray near the fastening screw. This is caused by a momentary short circuit of the power supply and a large short-circuit current. Therefore, it is necessary to eliminate the fault before installing a new fuse. It is not advisable to blindly install thicker fuses without identifying the cause. To prevent damage to electrical appliances and fire hazards.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由莫子若转载自XC Official Website,原文标题为:What is the reason why the fuse keeps burning out?,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关研发服务和供应服务
相关推荐
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
The Installation Precautions for Current Fuses
The installation of current fuses is crucial for ensuring the safety and proper functioning of electrical circuits. Here are some important installation precautions to keep in mind.
What is A Self Recovery Fuse
Self recovery fuse is an overcurrent electronic protection component that uses a polymer organic polymer under high pressure, high temperature, and sulfurization reaction conditions.After mixing with conductive particle materials, it is processed through a special process. Habitually applying PPTC (Polymer Positive Temperature).
旭程(XC)保险丝选型指南
目录- Company Profile Fuse User's Manual Fuse Auto Fuse Fuse Holder Thermostat
型号- 06F,3S,C0015302Z,C0040302Z,3T,10C,06T,C0060303Z,4F,KSD9700,C0030301Z,6CH,C7500301Z,4T,C0015301Z,C0070303Z,4TE,C0040303Z,8TE,C0025302Z,5C,KSD305,5F,5G,C4000302Z,5H,9L,KSD301,C2000302Z,C0030302Z,10FV,C0020301Z,5S,C7500302Z,5T,C0010302Z,24F,12F,32F,C0080303Z,5SH,6B,6C,C0025301Z,6F,6G,24T,6H,12T,C3000301Z,C4000301Z,C5000301Z,2F,C2000301Z,C0030303Z,32T,R3-13,5GH,R3-12,R3-11,5CH,6S,C0020302Z,6T,2T,5TE,XC-1,BS1362,C0010301Z,C3000302Z,5TR,3F,3G,C5000302Z,C1000302Z,XC-2,C0050303Z,C0035302Z,C0020303Z
The Impact of Fuse Aging on Usage
After the fuse ages, there is no danger of generating the current that should be cut off and the fuse not blowing. The aging of a fuse is equivalent to a decrease in the rated value (current) rather than an increase, resulting in the circuit being cut off at a small overload current or pulse.
Temperature Characteristics of Current Fuses
Current fuses exhibit specific temperature characteristics that play a crucial role in their performance and reliability. The behavior of a current fuse in response to temperature changes is determined by several factors.
Factors Affecting the Lifespan of Fuses and Their Evaluation
In this article, XC tells factors that affect the lifespan of fuses.
Selection of Current Fuses in Automotive Circuits
In automotive circuits, the selection of current fuses is of great significance for ensuring the safe operation of the vehicle. There are several key factors to consider when choosing a current fuse for an automotive circuit.
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
Essential Knowledge for Selecting Automotive Fuses
When a certain overload current passes through, the heat generated is radiated to the surrounding environment through the melt and shell, and the heat dissipated through convection, conduction, and other means gradually reaches a balance with the heat generated. If the generated heat is greater than the dissipated heat, the melt temperature can increase; When the temperature reaches or exceeds the melting point of the melt, the melt melts, fuses, and cuts off the current, playing a role in safety protection of the circuit.
The Role of Current Fuses in Smart Meters
Current fuses play a vital role in smart meters. Firstly, they provide protection against overcurrent events. Smart meters are used to measure and manage electricity consumption accurately. However, electrical circuits can sometimes experience sudden surges in current due to various reasons such as power outages and subsequent restoration, short circuits in the electrical grid, or the malfunction of connected electrical appliances.
Precautions for Using Fuses
The fuse is connected in series with the circuit, installed vertically, and installed on each phase line; Fuses are not allowed to be installed on the neutral line of a two phase three wire or three-phase four wire circuit.The power input terminal of the spiral fuse should be connected to the center point of the base, and the output wire should be connected to the threaded shell; This insurance is used in places with vibrations.
Common Sense for Fuses
A fuse refers to a self destructing fuse that experiences significant surges or other current exceeding limits in a circuit; In order to protect the components of other parts of the circuit where the fuse is located and the equipment is normal, the cost of replacing the fuse can be ignored compared to replacing the entire circuit that may be damaged. Due to the fact that fuses are a common element that needs to be replaced, we will introduce two basic concepts and provide a more in-depth introduction to fusion applications and testing and diagnostic methods.