Description of Metal Materials for Self Recovering Fuses
Everyone knows about fuses, but the self recovering fuse (PPTC) in fuses may not be well understood.
In fact, PPTC self-healing fuses, like the fuses we all know, play a role in limiting current and achieving circuit protection. Simply put, once the current in the circuit exceeds the specified current, it will cut off the current.
In daily life, the application of fuses can be seen everywhere, such as in household appliances. But do you know what material it is made of?
Self recovery fuse is an innovative type of fuse with more technical content and wider application range than ordinary fuses. It has the characteristic of being recoverable, so it must use easily melted metal materials to cut off the current in case of overcurrent and achieve protective effect. And this easily melted metal material is usually lead antimony alloy wire.
Mainly using aluminum alloys with Mg as the main element (Mg based aluminum alloys have good corrosion resistance, strong thermal conductivity, and outstanding strength), and adding some metal materials (such as magnesium) to enhance its hardness.
The self-healing fuse made of this material has low density, strong compression resistance, and good heat dissipation function, and can meet the standards of 3C products in terms of quality and appearance.
There are various specifications and models of self-healing fuses, each with its own strengths. You can choose the corresponding fuse according to your different circuit protection needs, but do not use it indiscriminately to avoid damage to the circuit.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由玄子转载自XC Official Website,原文标题为:Description of Metal Materials for Self Recovering Fuses,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Temperature Characteristics of Current Fuses
Current fuses exhibit specific temperature characteristics that play a crucial role in their performance and reliability. The behavior of a current fuse in response to temperature changes is determined by several factors.
Factors Affecting the Lifespan of Fuses and Their Evaluation
In this article, XC tells factors that affect the lifespan of fuses.
Professional Knowledge of Self-healing Fuses
The operating principle of a self-healing fuse is a dynamic balance of energy. The current flowing through the self-healing fuse generates a certain amount of heat due to the thermal effect of the current (self-healing fuses all have resistance values), and the generated heat is completely or partially dissipated into the environment. The heat that is not dissipated will increase the temperature of the self-healing fuse components. The temperature during normal operation is relatively low, and the heat generated and dissipated reaches a balance.
旭程(XC)温控器选型指南
目录- 公司介绍 Company Profile 温控器 Thermostat 保险丝 Fuses 企业资质与专利 Qualification and Patents Certifications
型号- C0015302Z,9K7.SK-B5,KSD305系列,9K7.SK-B3,CG-B,CG-A,SK-B1系列,9K7CG-XXX,SK-B5系列,KSD301系列,KSD307B,SK-A1,KSD307 SERIES,SK-A4,C0015301Z,9K7.SK-C2,SK-C2系列,C0025302Z,C4000302Z,KT SERIES,9K7.JW-A072,C2000302Z,CG-B系列,C0080303Z,9K7.SK-B11,JW-C系列,KSD305B,JW,KSD305-XXXX/XXXX,SK-C2,9K7SK-XXXX/XXXXX,C4000301Z,C5000301Z,SK,CG SERIES,9K4307-XXXX/XXXX,C0020302Z,CG,KT,KSD9700 SERIES,SK-B1,C5000302Z,C1000302Z,C0050303Z,SK-B5,C0035302Z,C0020303Z,C0040302Z,KSD307系列,KSD301-XXX/XXXXXX/XXX,9K7KT-XXXX/XXXXX,9K7.SK-F3,SK-F5系列,JW-B系列,C0060303Z,KSD9700,C0030301Z,KT系列,C7500301Z,C0070303Z,C0040303Z,SK-A1系列,9K9.9700-XXXXXXX,KSD305,KSD307,KT-A2,KT-A1,KSD301,C0030302Z,JW SERIES,JW系列,C0020301Z,C7500302Z,C0010302Z,9K4.307B,JW-A系列,CG-A1,C0025301Z,CG系列,KSD9700系列,C3000301Z,C2000301Z,C0030303Z,KT-A系列,SK SERIES,JW-B,JW-C,SK系列,KSD301 SERIES,KSD305 SERIES,CG-B2,C0010301Z,SK-F5,C3000302Z,SK-F6,9K7JW-XXXX,CG-A系列,KSD307-XXXX/XXXX,KT-A,9K4.307
Calculation Method for Melt Current of Fuse Fuses
The current of a fuse includes two aspects, one is the rated current of the fuse tube, and the other is the rated current of the melt, which cannot be confused.
Selection of Current Fuses in Automotive Circuits
In automotive circuits, the selection of current fuses is of great significance for ensuring the safe operation of the vehicle. There are several key factors to consider when choosing a current fuse for an automotive circuit.
Explanation of Parameters in the PPTC Specification for Self Healing Fuses
This is very simple. As long as you know the meaning represented by the parameters in the specification book, you can clearly and quickly view the PTC specification book for self recovery fuses.
Self Recovery Performance and Working Process of Self Recovery Fuses
Traditional fuses are installed in circuits. When an overcurrent occurs due to a fault or abnormality in the circuit, the fuse itself melts to cut off the current and protect the circuit. However, due to the fact that traditional fuses can only protect once and need to be replaced if burned out, some products still cannot resume operation after troubleshooting or abnormal overcurrent disappears. As a new type of overcurrent protection device, the self-recovery fuse has the function of automatic recovery, which can meet the performance requirements of similar applications.
Encapsulation Forms of Current Fuses
The encapsulation of current fuses is an important aspect that affects their performance, durability, and safety.
Essential Knowledge for Selecting Automotive Fuses
When a certain overload current passes through, the heat generated is radiated to the surrounding environment through the melt and shell, and the heat dissipated through convection, conduction, and other means gradually reaches a balance with the heat generated. If the generated heat is greater than the dissipated heat, the melt temperature can increase; When the temperature reaches or exceeds the melting point of the melt, the melt melts, fuses, and cuts off the current, playing a role in safety protection of the circuit.
Electric Vehicle Malfunctions Due to Lack of Fuses or Diodes
With the development of life, electric vehicles have also become popular. In order to facilitate people‘s travel, many families have started to use electric vehicles, which are convenient and affordable. However, there are still many unknown problems that arise during use. Today, the editor will briefly talk about the structural issues of electric vehicles.
The Role of Current Fuses in Smart Meters
Current fuses play a vital role in smart meters. Firstly, they provide protection against overcurrent events. Smart meters are used to measure and manage electricity consumption accurately. However, electrical circuits can sometimes experience sudden surges in current due to various reasons such as power outages and subsequent restoration, short circuits in the electrical grid, or the malfunction of connected electrical appliances.
The Installation Precautions for Current Fuses
The installation of current fuses is crucial for ensuring the safety and proper functioning of electrical circuits. Here are some important installation precautions to keep in mind.
Common Sense for Fuses
A fuse refers to a self destructing fuse that experiences significant surges or other current exceeding limits in a circuit; In order to protect the components of other parts of the circuit where the fuse is located and the equipment is normal, the cost of replacing the fuse can be ignored compared to replacing the entire circuit that may be damaged. Due to the fact that fuses are a common element that needs to be replaced, we will introduce two basic concepts and provide a more in-depth introduction to fusion applications and testing and diagnostic methods.
Several Factors Influence the Lifetime of Current Fuses
The lifetime of a current fuse is influenced by several factors. Firstly, the current rating of the fuse plays a crucial role. If a fuse is constantly operating near or at its rated current, it will experience more heat buildup and stress over time, which can shorten its lifetime.
电子商城
现货市场
登录 | 立即注册
提交评论