GRL Provides Fuses, and Fuse Switches in GW155 Wind Turbines
Reliable Protection for Clean Energy
Goldwind is a global leader in clean energy, energy conservation, and environmental protection. GRL participated in the 3 million kilowatt wind power poverty alleviation project in Inner Mongolia province, China, through the wind turbines of Goldwind Technology
Goldwind's GW155-4.5MW wind turbine is the first 4.5MW wind turbine in China.
3 million kilowatts of wind power use GW155 in the poverty alleviation project in Inner Mongolia.
GRL provides fuses, and fuse switches in GW155 wind turbines.
Wind Power System Overview
The wind power generation system consists of wind turbines, overhead lines, transformers, box transformers, and grid boxes.
The specific classification is shown in the figure below
The on-site control station of the wind power control system includes: tower main control cabinet, nacelle control station cabinet, pitch system, converter system, on-site touch screen station, Ethernet switch, field bus communication network, UPS power supply, emergency shutdown backup system, etc.
Nacelle Control Cabinet
The tower nacelle cabinet is located in the cabin and mainly provides power supply for wind blades, yaw motors, etc. The nacelle control cabinet is a UPS power cabinet. The incoming circuit adopts the busbar system solution, and the main switch is a 160A fuse switch disconnector.
Tower Base Control Cabinet
The tower base cabinet is located in the wind tower. This cabinet contains a 690V fuse switch disconnector,400V, and 230V air switch, 400V and 230V motor protector, 690V surge arrester, and other low-voltage components. Some electrical components such as fuse switch disconnectors control the different electrical systems in the wind turbines.
There are many control switch buttons on the door of the tower base cabinet to facilitate the operation of the wind turbines.
Fuse Switch Disconnector
GRL 160A fuse switch disconnector is applied to the wind turbines of Goldwind. GRL's fuse switch disconnector passes the vibration test in order to meet the requirements. When the overload current is 10kA, the GRL low power consumption fuse can quickly be blown.
Customer Application
Since the first GW155-4.5MW wind turbine was put into operation in June 2019, the availability rate has remained above 99.7%. The fuse-type isolating switch inside the wind turbines, hasn’t been blown yet.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由梨花落风转载自GRL Official Website,原文标题为:Goldwind Clean Energy project,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Enhancing Residential Electricity Stability with GRL Fuse Switches in Country Garden Communities
GRL provides fuse switches for Country Garden‘s residential electricity projects, including Power distribution boxes and switchgears in Country Garden (Jinan Olympic Sports Center) community. GRL applies 400A busar-type and HH15-1600A isolating switch fuse group in cable branch boxes and box-type substations. GRL is Country Garden‘s partner in Guangdong, China.
应用方案 发布时间 : 2024-11-13
GRL DNH7 Fuse Switch Provides Safe Protection for TBEA‘s JP Box
Born to Be Safe: GRL‘s Fuse Switch Provides Safe Protection for TBEA, a Leading Power Transmission and Transformation Company. TBEA faced a temperature rise issue in a JP box project using an international brand fuse switch. GRL offered a solution by replacing the fuse switch with its DNH7 model, modifying the switchgear layout, and using a low-power fuse. The final temperature rise was within the qualified standard.
应用方案 发布时间 : 2024-11-13
State Grid‘s Power Distribution Upgrade used GRL‘s Fuse-links, Switches, and Busbar Systems
State Grid Corporation of China, the largest grid builder and operator in China, uses GRL products including fuse-links, isolator switches, and busbar systems for safer power distribution boxes. GRL provides a range of fuse coverage for different currents and adopts derating treatment in plateau areas. Toughened DMC materials are used for fuse disconnectors in complex environments. GRL also assisted in launching an integrated solution for transformers and integrated distribution boxes, with busbar systems available in different sizes for energy distribution.
应用方案 发布时间 : 2024-11-09
日本电产集团综合产品目录(Nidec Group Products Catalog)
型号- PM4系列,H300,D SERIES,NRFEIS-5060,DFS,GATS-2000 SERIES,TPI SERIES,GATS-7800 SERIES,R-6100,TVX,GATS-6300,GATS-8600,SX-20,RWI SERIES,ZI20A,GATS-7500系列,LSR-3230,BP100,RSH,GATS-7700 SERIES,K-MC1000,P2H系列,E300,GATS-2000系列,GATS-6300系列,NVM-6060GCP,VL-H系列,GATS-7500,MH3NCV,VL SERIES,GATS-7800系列,SS-SV,DEWE3-A4,TPI,TVX SERIES,RGA20,NRTES-1000 SERIES,FCPL,ΜV1,RSH系列,ZG SERIES,ID300,FMD,TPI系列,GATS-8600系列,S-CART,GATS-6300 SERIES,KS,CM,R-580,SS-SV SERIES,ANEX SERIES,LD SERIES,VP600GC,GE15FR PLUS,MD2,ANEX系列,NRTES-1000,P2H SERIES,FFB,VL系列,LS,RSH SERIES,RVL,VL-H SERIES,RVP,F600,SS-SV系列,S-FLAG,GATS-7500 SERIES,REC-92FT,DEWE3-PA8,ECO-KA,KCV1000-5AX,S-CART-V1000-LFT,RVL SERIES,RVP SERIES,R-700 SERIES,P2H,ZE16C,CPLS,S-CART-V500,HM500S,VM53RⅡ,GATS-7700,ANEX,NRTES-1000系列,HM-X6100,RWI,TVX系列,KA SERIES,S-CART-MINI,GATS-2000,PM4,VL-H,GATS-7700系列,CBZ,GH,GATS-8600 SERIES,R-700,R-5920系列,NRFEIS-3570,DFS SERIES,MVR-HX,MAF130EⅡ,BL-V20,ECO-KA SERIES,SERIES S-FLAG,RWI系列,HE,GATS-7800,R-5920
GRL Solar Power Solutions: Isolator Switch, Fuse Switch Disconnector And HRC Fuse Link
In the rapidly growing renewable energy sector, reliable and efficient solar power solutions are crucial. At GRL, we specialize in delivering high-quality, high-performance solar power solutions, including Isolator Switches for solar, Fuse Switch Disconnectors, and HRC Fuse Links. Our products are designed to ensure the safety, efficiency, and longevity of solar power systems, making them a preferred choice for professionals in the solar industry.GRL’s Product Range for Solar Power SolutionsIsolator Switch for Solar:Essential for ensuring safety during maintenance and repair, the GRL Isolator
原厂动态 发布时间 : 2024-11-14
Littelfuse NPI Summary
型号- PLA172P,SMF 200W,DMA80IM1600HB,QVXX16XHX SERIES,CPC1561B,SV6016DX,SV60XX SERIES,W8245EC450-480,M2325HA400-450,407 SERIES,SP3025-04HTG,SP4010,SLD6S,SP3205,AQ3522-01FTG,IX4310T,SP2525NUTG,DMA10P1200UZ,AQ3102,MITI-7,AQ3530-01FTG,W2865HA680-720,SMF SERIES,SP712,DMA SERIES,SP1250-01ETG,SMF4L,X2 SERIES,PSX,PPGXXXJX,ITV SERIES,SD22,DMA10P1600HR,IX4351NE,SP4322,AQ22-01FTG,AHRL
GRL Provides Fuses and Fuses for BYD AUTO Energy Storage Battery Production Line
GRL provides fuses, fuse bases, and fuse switches for BYD’s Shenzhen production plant. The equipment damage rate of BYD’s Shenzhen production line decreased by 5% due to the timely blowing of fuses.
原厂动态 发布时间 : 2024-11-01
GRL DNH1 Fuse Switch Disconnector: Upgraded for Maximum Safety and Efficiency
The GRL DNH1 fuse switch disconnector is an innovative solution for maximum safety and efficiency in electrical distribution systems. Its compact design reduces footprint by up to 52% in width and 38% in height, while enhancing safety with advanced short-circuit protection. Suitable for AC 800V to 1800V systems, it‘s widely used in renewable energy, industrial automation, and power grids.
产品 发布时间 : 2024-11-13
Maximize Equipment Safety with Current Limiting Fuses
High voltage current-limiting fuses are becoming an indispensable solution across various applications, offering exceptional protection for the equipment in case of overcurrent or short circuits.
技术探讨 发布时间 : 2024-11-05
GRL DNESS Energy Storage Fuses—The Reliable Guardian of High-Current Protection
GRL‘s DNESS Energy Storage Fuses are specialized protective devices for Energy Storage Systems (ESS), offering robust overcurrent protection. Unlike traditional fuses, they handle high voltage and current demands, especially in DC environments. GRL‘s DNESS series simplifies solutions, enhances reliability, and is cost-efficient, supporting the future of ESS across various sectors.
产品 发布时间 : 2024-11-13
GRL Supplied the Solar Panel Combiner Box and DC Fuse Box for Photovoltaic Power Generator System
This is the first time that GRL’s DC isolator switch and DC fuse have appeared in the South American market. GRL’s 400A switch disconnector and DC fuse can adapt to the use environment in many countries and meet the usage habits of the global photovoltaic market.
应用方案 发布时间 : 2024-11-13
Littelfuse Q1–Q3 2020NPI Summary*
型号- ITV SERIES,R2009,PLA172P,SV6012XX,PPTC SERIES,M2325HA450,ITV4030 15A,SP3025-04HTG,IXYK140N120A4,ITV9550 30A,IXYT85N120A4HV,IXYT55N120A4HV,SP3025,SP3205,SV6020XX,IX4310T,SP3025 SERIES,SCR SV60XX SERIES,SP2525NUTG,SMF4L SERIES,IXYN140N120A4,W2865HA680-720,SMF SERIES,IXYH55N120A4,ITV5432 30A,SP712,DMA SERIES,IXTP14N60X2,SP1250-01ETG,X2 SERIES,PPGXXXJX,DMA10P1600HR,SMDC SERIES,IX4351NE,ITV9550 45A,SV6016DX SERIES,LSIC1MO120E0080,SMF 200W,DMA80IM1600HB,IXYX140N120A4,SV6016DX,M2325HA400-450,IXTY14N60X2,SOD882,407 SERIES,SP4010,SV6025XX,AQ3522-01FTG,M2325HA400,DMA SERIES,2865 A,DMA10P1200UZ,AQ3102,AQ3530-01FTG,SMF4L,SCR SERIES,IXYH85N120A4,ITV4030 12A,ITV SERIES,SV6016XX,PPGXXXJX SERIES,SP1250,SP4322
GRL Adopts DNH18 Fuse-type Isolating Switch, with a Special Diversion Groove on the Side, to Create a Safe Distribution Box
Shanghai Zhixin, China‘s largest transformer supplier, faces a temperature rise issue in cable branch boxes. GRL Electric offers a solution with its DNH18 fuse-type isolating switch, featuring a special diversion groove that quickly guides hot air out of the box, ensuring safety. The switch also passes the 10KA short-time withstand current test with a special low-power fuse that fuses quickly without ceramic explosion. GRL and Shanghai Zhixin have a long history of cooperation, with GRL‘s DNH18 switches widely used in power grid projects in Shanghai, Hangzhou, and Suzhou.
应用方案 发布时间 : 2024-11-13
电子商城