Coolant Distribution Units (CDUs) That Help Lower Data Center Total Cost of Ownership and Maximize Power Density
Boyd’s Coolant Distribution Units (CDUs) help lower data center total cost of ownership. CDUs right-sized and custom configured for specific applications mean hyperscale compute systems get the exact, optimal cooling performance the system needs, when it needs it. Intelligent controllers with operation logic, automatic diagnostics and trouble shooting, protection and warning functions, as well as smart flow, pressure and temperature controls manage system performance to spike with peak demand while remaining economical and efficient during non-peak operation and prevent problems before they occur. Blind mate quick disconnects with 360 swivel fittings make servicing systems fast for minimized maintenance downtime.
Decades of reliable field performance have enabled us to fine tune system design with validated thermal reliability and leak-free performance. When server or chassis heat loads outpace what traditional air cooling can achieve, CDUs offer higher thermal performance in smaller packages. Negating the need for bulky heat sinks, fan trays and components in air cooled systems that create significant environmental noise pollution and consume more energy, integrated CDUs enable greater server power density with quieter operation and more efficient natural resource utilization. Integrate CDUs directly into facility water or facility-level cooling systems, or design self-contained CDUs that offer a different level of flexibility. Cool the chassis, blade or integrate CDU cooling capacity down to the processor or silicon. CDUs can be designed to integrate into existing data center or chassis configurations. The flexibility and space-saving benefits of CDUs may enable data center and chassis designers to completely rethink footprint configuration opportunities to maximize power density. Boyd CDUs are designed to meet IEC62368-1 and tested to withstand 3X maximum working pressure. All new subcomponent designs undergo harsh maximum pressure testing to destruction. Reliability testing incudes thermal cycling, min /max storage and packaging testing.
In Row Coolant Distribution Unit (CDU)
Freestanding In-Row Coolant Distribution Units (CDUs) are designed to manage high heat loads in hyperscale compute and data center environments. Full liquid cooling systems that distribute coolant in and out of a series of server chassis capable of tying into existing facility cooling systems or designed to be fully self-contained.
In Rack Coolant Distribution Unit
In Rack Coolant Distribution Units (CDUs) are designed to integrate into a server chassis and distribute coolant to a series of servers or heat sources. In-rack CDU configurations are available for 2U and 4U space and feature redundancy pump design, dynamic condensation-free control, automatic coolant replenishing, a bypass loop for stand-by operation and automatic leak detection.
Coolant Distribution Unit Components
CDU components typically include manifolds, rear door heat exchangers and/or a reservoir pumping unit (RPU) for full liquid cooling system functionality.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由翊翊所思转载自AAVID,原文标题为:Coolant Distribution Unit (CDU),本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
【产品】爱美达冷却液分配单元(CDU),灵活省空间的超大规模计算系统冷却方案
BOYD的冷却液分配单元有助于降低数据中心的总体拥有成本。CDU尺寸合适且针对特定应用进行了定制配置,这意味着超大规模计算系统可在需要时获得系统所需的精确,最佳冷却性能。具有操作逻辑,自动诊断和故障排除,保护和警告功能以及智能流量,压力和温度控制功能的智能控制器可管理系统性能,以高峰需求达到峰值,同时在非峰值运行期间保持经济高效,并在故障发生之前预防问题发生。
Aavid‘s Liquid Cooling Systems: Modular or fully customized liquid cooling optimized for improved heat dissipation in condensed volumes
Liquids have a high capacity for heat transfer and can remove and dissipate heat quickly and effectively. This enables Liquid Cooling Systems (LCSs) that utilize liquid and optimized system components, such as pumps, compressors, or cold plates, to cool high power density devices more efficiently than air cooled systems of the same volume. Aavid, Thermal Division of Boyd Corporation, specializes in engineering and the production of liquid systems as well as fully optimized individual thermal and sealing components.
【产品】可定制设计的爱美达铝制板翅式换热器,可以设计用于气体,液体和两相流体的任意组合
爱美达的板翅式换热器可以设计用于气体,液体和两相流体的任意组合。爱美达经验丰富的工程团队会仔细选择板和翅片的层数,板和翅片的尺寸以及翅片的类型,以实现最佳性能。歧管和安装支架按规定焊接到位,可以添加任何需要的油漆或涂层(包括符合MilSpec的要求)。
爱美达机架式CDU和行级CDU助力数据中心散热,提供最高700千瓦冷却能力
自从数据中心首次出现和不断发展,爱美达一直引领着企业冷却和工程材料解决方案的技术创新,利用这几十年的专业知识开发了一系列先进的热解决方案和系统,,前瞻性液体冷却创新和系统元件——冷却液分配单元(CDUs)。
Energy Consumption in Data Centers: Air Versus Liquid Cooling
As the data center industry continues to evolve and address rising energy consumption challenges, investors have opportunities to support and capitalize on advancements in energy-efficient technologies that innovate and improve sustainability.
What Is A Coolant Distribution Unit (CDU)?
A Coolant Distribution Unit (CDU) is a system that enables smaller, more efficient, more precise liquid cooling in a data center at Rack level, often integrating facility water. The CDU circulates coolant in a closed loop system within the rack on the secondary (Cooling Application) side and utilizes facility water on the primary (Heat Rejection) side. A CDU has a pump, reservoir, power supply, control board and a heat-exchanger as the key components. Filters, flow meters, pressure transducers, and other devices are also used in managing the operation of the CDU in conjunction with the Server
【经验】爱美达CDU设计需要注意的5个事项
爱美达在CDU设计方面有丰富的经验,本文针对CDU机械设计、 通讯/控制器和监视器、泄漏检测/冷凝风险、维护、热交换器内容进行说明。