Electrolyte analyzer, as an important equipment in clinical testing, is mainly used to detect the concentration of potassium ions, sodium ions, chloride ions, ionized calcium and other key electrolytes in human body fluids, which is crucial for maintaining the osmotic pressure balance in human blood and body fluids. As an advanced biomolecular signal processing chip, the Nanochap BMS002 chip is used in electrolyte analyzers to greatly improve the accuracy and efficiency of the test, demonstrating its excellent core technology.
Nanochap BMS002 Chip Core Technology
High Sensitivity and Low Noise
The BMS002 chip integrates a highly sensitive 4-electrode current measurement module, which can effectively detect weak biological signals and is particularly good at recognizing subtle ion concentration changes in electrolytes. Its excellent low-noise performance ensures stable signal transmission, weakens external interference and improves detection accuracy.
High-precision Analog-to-digital Converter (ADC)
Built-in 16-bit high-precision ADC supports 40 to 2048 times oversampling, which greatly enhances the resolution and accuracy of ion concentration detection and ensures highly accurate results.
Embedded ARM Cortex-M0 MCU
The integrated ARM Cortex-M0 MCU brings high efficiency data processing capability to the chip, which can instantly analyze the biomolecular signals and quickly output the detection conclusions.
Multi-functional Impedance Detection Module
Equipped with an impedance detection module, it accurately measures electrolyte impedance at a rate of 250KSPS and 10-bit resolution, providing more dimensional data support for electrochemical research.
In the electrolyte analyzer, the BMS002 chip achieves the ion concentration detection in the following main steps:
Signal Acquisition: The chip detects changes in ion concentration in the electrolyte solution through the built-in electrodes, and converts the ion concentration into an electrical signal.
Signal Processing: Convert the collected analog electrical signal into a high-precision digital signal and perform signal analysis to extract the characteristic information related to the ion concentration.
Data Calculation: Based on the results of signal analysis, the chip calculates the concentration value of each ion through the built-in algorithm.
Comparison with Traditional Electrolyte Analyzer
Detection Accuracy
BMS002 chip adopts the method of direct measurement of biomolecular signals. Compared with the chemical method or atomic absorption method of traditional electrolyte analyzers, it reduces the interference of factors such as temperature, humidity, reaction time, etc., and thus improves the accuracy and stability of detection.
Detection Speed
Compared with the long waiting time of traditional detection, BMS002 chip utilizes fast data processing and high sensitivity technology to shorten the detection cycle and improve efficiency.
Automation
Traditional equipment is complicated to operate and requires manual intervention. BMS002-based electrolyte analyzer can realize full automation, just need to place the sample can be automatically tested and give the results, simplify the workflow of health care workers.
Cost and Size
The highly integrated design of the BMS002 chip not only reduces the cost of the device, but also reduces its size, making the new electrolyte analyzer more economical, portable and easy to carry and store.
The application of the Nanochap BMS002 chip in electrolyte analyzers demonstrates its excellent core technology and significant advantages. With the advancement of medical technology and the increasing demand for health, the BMS002 chip is expected to play an important role in more medical fields.
Advantages and Features of Nanochap Nine Senses Series BMS002 Biomolecular Signal Processing Chip:
High Detection Accuracy: 16bits ADC, supports 40-2048 oversampling configuration.
High Integration: integrated crotex-M0 core, 1-32KHz complex impedance detection circuit, built-in adjustable bias voltage micro-current detection circuit, support four-electrode current detection.
Multi-detection Types: can detect blood glucose, lactate, uric acid, bilirubin, electrolytes, creatinine, cholesterol, ketone bodies and other biomolecular signals.
Product Parameters
Supply voltage: 1.35V-1.65V
Communication interface: UART
Debugging interface: SWD
Package: QFN32 4mm×4mm
Application Scenario: impedance measurement, medical/industrial biomolecular sensors, DNA/RNA/miRNA/protein detection, peptide/enzyme/metabolite detection, biomarker detection
Current Detection
Number of electrodes: 4
ADC precision: 16bits
Detectable parameters: lactate, uric acid, glucose, electrolytes, bilirubin, creatinine, ketone bodies, cholesterol, other trace parameters
Impedance detection
ADC: 250KSPS, 10bits
Impedance range: 1-300kΩ
Impedance phase range: -90° ~90°
- |
- +1 赞 0
- 收藏
- 评论 0
本文由上山打老虎转载自Nanochap Official Website,原文标题为:Nanochap BMS002 Intelligent Electrolyte Analyzer, Leading the Upgrade of Body Fluid Analysis Technology,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关研发服务和供应服务
相关推荐
Nanochap Neurostimulation Chip Stim Engines ENS001 in Anti-Motion Sickness Bracelet, Highly Integrated to Achieve Lightweight and Miniaturization
In recent years, with the continuous progress of science and technology, neurostimulation technology has received more and more attention in the fields of medical treatment and massage. Among them, the use of Nanochap‘s neurostimulation chip, Stim Engines ENS001, in anti-motion sickness bracelets has become a much-anticipated innovation.
Nanochap ENS001 Chip Enables Varicose Vein Radiofrequency Therapy, Opening a New Era of Non-Invasive and Efficient Treatment
The application of Nanochap ENS001 chip in varicose vein RF therapy device not only improves the treatment accuracy and safety, but also brings more convenient and personalized treatment solutions for patients.
Nanochap Bio-molecular Signal Processing Chip Nine Senses Series BMS002 in Intelligent Diapers
The use of Nanochap‘s biomolecular signal processing chip Nine Senses Series BMS002 on smart diapers not only reflects the innovative application of technology in the field of medical and health care, but also provides a more convenient and efficient solution for users‘ health management.
Knowles Introduced the MD Series, A Range of Medical-grade Capacitors for Implantable Designs
Knowles Precision Devices, a division of Knowles Corporation, recently introduced the MD Series, a range of medical-grade capacitors for implantable designs.The MD Series encompasses C0G, X7R and X5R monolithic ceramic chips.
Nanochap Bio-molecular Signal Processing Chip Nine Senses Series BMS002 in Blood Sugar Uric Acid Tester, Simultaneous Detection, Efficient and Convenient
Nanochap biomolecular signal processing chip Nine Senses Series BMS002 in the blood glucose uric acid tester on the use of a wide range of applications and great potential for development. It can not only improve the accuracy and speed of detection and simplify the operation process, but also is expected to reduce medical costs and alleviate the economic burden of patients.
Innovative Application of Nanochap NNC6121 Chip in Eye Massage Devices Reinventing Eye Comfort
The application of Nanochap‘s NNC6121 highly integrated programmable chip in eye massagers has important practical value. With its highly integrated and programmable features, the chip realizes personalized treatment and precise control of the eye massager and enhances the user experience.
OM6681x蓝牙双模片上系统
描述- 该资料介绍了OM6681x系列蓝牙双模系统级芯片(SoC)的特性、应用领域和引脚说明。该芯片支持蓝牙5.2双模式功能,内置多个转换器和控制器,具备高性能音频处理能力,适用于健康医疗、智能家居等领域。
型号- OM6681QWX,OM6681X,OM6681QW
Nanochap Launches Programmable Neuromodulation Platform Chip - Stim Engines ENS001
Nanochap, a biochip developer, recently announced a new System-on-Chip (SoC), Stim Engines ENS001 (Figure 1), designed for neuromodulation applications. It is the industry‘s first SoC with multi-channel, fully programmable stimulation parameters and waveforms, and support for multiple stimulation modes, which can be flexibly applied to a variety of wearable and implantable nerve/muscle stimulation and neuromodulation applications. As a platform chip for neuromodulation, it enables manufacturers in this field to create unique and highly flexible system solutions for their product designs.
Nanochap EPC001 Chip Empowers EEG Cap: A Precision Revolution in Vital Signs Monitoring
The application of Nanochap EPC001 vital signs detection chip in EEG cap not only reflects its excellent core technology advantages, but also brings new development opportunities in the field of medical technology.
Nanochap Nerve Stimulation Chip Stim Engines Series ENS001 Is Widely Used for Extracorporeal Diaphragmatic Pacemakers
Nanochap Nerve Electrical Stimulation Chip Stim Engines Series ENS001 is an innovative biochip that stimulates the contraction of the diaphragm through microelectronic technology by transmitting electrical impulses to the human diaphragmatic nervous system. The use of this stimulation chip in an extracorporeal diaphragm pacemaker is a combination of this stimulation chip with existing pacemaker devices to achieve precise stimulation of the diaphragm and help restore its normal function.
Nanochap Bio-molecular Signal Processing Chip Nine Senses Series EPC001 in Intelligent Steering Wheels
Nanochap, with its leading Nine Senses Series EPC001 biomolecular signal processing chip, has successfully realized the real-time collection and transmission of health data on the smart steering wheel, bringing a brand-new intelligent experience to drivers.
FDTI FT60X Series Products Are Used in Medical Monitoring
This paper mainly introduces the application cases of FDTI USB 3.0 to FIFO interface bridge chip in medical monitoring products.
How to Choose the Right Small Bluetooth Chip Solutions of SILICON LABS for Medical Devices and Wearables?
Silicon Labs has been delivering small, application-optimized Bluetooth solutions for the manufacturers of medical devices and wearables for decades. This article showcases eight of Silicon Labs’ smallest Bluetooth chips optimized for medical devices and wearables, for the purpose of helping users choose the smallest optimal Bluetooth chip for their application.
Nanochap Neurostimulation Chip Stim Engines Series ENS001 Features Higher Precision and Stability in Foot Drop System
As a new type of medical equipment, foot drop system plays an increasingly important role in helping patients restore lower limb motor function. In foot drop system, the application of Nanochap nerve stimulation chip Stim Engines Series ENS001 can better provide technical support for product improvement.
适用于射频应用/医疗应用的片式电感器(绕线开路)技术参数
描述- 该资料介绍了FASTRON品牌的线绕片式芯片电感器,适用于高频电路中的射频(RF)应用。这些电感器具有金闪垫金属化提供更好的可焊性,并采用保护性的封装设计,支持表面贴装技术。产品尺寸紧凑,从0402到1812不等,并提供卷带包装。此外,还提供了铁氧体芯版本以满足更高电感值的需求。
型号- 0402AS-1N0X-YY,0402AS-1N0K-01
电子商城
品牌:Nippon Chemi-Con
品类:Aluminum Electrolytic Capacitor
价格:
现货: 200,000
品牌:硕凯电子
品类:Chip Ferrite Bead for High Current
价格:¥0.0375
现货: 56,057
现货市场
服务
可贴片PCB尺寸50*50mm-580*610mm;PCB厚度0.3-8mm;贴装精度CHIP元件+0.03,BGA Pitch 大于0.25mm;元件尺寸0201-74*74BGA;元件高度:30mm。
最小起订量: 1 提交需求>
可定制LAMP LED、 CHIP LED、 PLCC LED、 汽车用车规级LED、COB LED的尺寸/电压/电流等参数,电压1.5-37V,电流5-150mA,波长470-940nm。
最小起订量: 30000 提交需求>
登录 | 立即注册
提交评论