Mission Critical: Maintain your RF cables and connectors 24 APR Mission Critical: Maintain your RF cables and connectors
Like most nice things, proper upkeep and handling is standard practice, Radio Frequency (RF) cables and Connectors are no exception. The RF signal which is transmitted between an (or between transmitter and antenna) can be compromised if the cables or connectors are not upheld. One of the easiest ways to receive the best performance for transmitting signals is to regularly maintain RF components.
Annual upkeep of RF cables and connectors will extend the lifespan, increase efficiency, minimize RF insertion loss, and limit gaps in transmission signals. Prolong RF cables and connectors live and produce more accurate and repeatable measurements by following these guidelines.
Connector Interfaces:
Interface Cleanliness - Clean interfaces prolong connector life and produce more accurate, repeatable measurements. Use connector endcaps to protect the cables and adapters when not in use (no passive voice).
Interface Cleaning Procedure:
Solvents: Connector Insulators, support beads, and seals are susceptible to solvent damage. Solvents can produce permanent physical and electrical damage. Isopropyl Alcohol is recommended for cleaning interfaces. It should be noted that connector interfaces should not be immersed in solvents of any kind because solvents can become trapped within the connectorized assembly. Trapped fluids can cause SWR, Phase, and Insertion Loss problems.
Applicators: Fibrous or Abrasive applicators can contaminate and even damage Interface surfaces. Clean lint-free swabs should be used. They need to be sharp enough and hard enough to remove dirt and debris without damaging surfaces and/or dislodging center pins.
Method: Dip a clean lint-free swab in clean isopropyl alcohol. Press excess alcohol out of the swab on a clean lint-free towel. Wipe the interface components as required to clean the interface. Blow-dry the interface with clean compressed air. Re-inspect the connector to verify that the interface is clean and ready for additional inspection procedures and interface gauging prior to use.
Interface Gauging: Incorrect center pin depths can produce inaccurate measurements and in the case of protruding cent pins can damage test devices, adapters, and test ports. Frequent Interface gauging can detect problems before they can ruin mating devices (see Table 1 for connector interface pin depths).
Recommended Coupling Torque:
Incorrect torque can produce inaccurate measurements and over-torque coupling can damage test devices, adapters, and test ports. Torque wrenches should be utilized to for all mate/de-mate processes (see Table 2 for recommended coupling torque values).
Cable Routing:
Bend radius - Care should be taken to avoid over-bending test cables beyond minimum bend radius guidelines. Over-bending can force the cable center conductor off-center and can force the outer
conductor out of round even to the point of kinking and fracture. Overbending results in degraded IL and SWR performance. It should also be noted that coiling cables at small diameters could force connector center pins to protrude beyond the required interface dimensions.
Twisting - Twisting test cables should be always avoided. Excessive twists can damage Cable assembly at the cable/connector junction or even mid-cable depending on how the twist is applied. Lower-level twists can cause measurement problems as well. Inducted stresses on test ports and device ports can damage the ports. Low-level stresses can cause connections to loosen up. When routing cables always connect any right angles first.
Cable assembly mate/de-mate process:
Interface alignment - Contact pins and dielectrics can be damaged if misaligned connectors are mated. Make sure that mating interfaces are parallel and on the center during the mate/de-mate cycle.
Interface Rotation - The plating and surface finish of outer and inner contacts can be damaged if connector bodies are allowed to rotate during the mate/de-mate cycle. Use wrench flats on connector bodies to keep them rotationally stationary while rotating the coupling nut during mate/de-mate.
Minimized load configuration - Allow the test cable to assume a natural bend configuration route between the test port and the device port. Loosen test port and device port connection when test configuration is largely different than test configuration. Route cable, connect device port loosely then tighten port connections to recommended coupling torque (see Table 2 above). This method will minimize most bend and twist loading issues.
Mission-critical systems are exposed to different harsh environments, high levels of radiation, intense heat, extreme cold, strong wind, heavy rain, or snow, and extreme vibration. Providing a high-quality RF/microwave transmit signal is crucial for all mission-critical RF electrical systems.
Equipment failure or malfunction can be prevented with proper maintenance, establishing default measurements, and understanding application use and conditions. Annual upkeep and maintenance for RF components will extend the lifespan, increase efficiency, minimize RF insertion loss, and limit gaps in transmission signals.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由涂抹转载自Smiths Interconnect Blogs,原文标题为:Mission Critical: Maintain your RF cables and connectors 24 APR Mission Critical: Maintain your RF cables and connectors,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Choosing the Right Interconnect Systems for Medical Device Designs
Given the demanding requirements of many medical applications, it’s important to consider to the many elements of connector design early in the development stage to ensure effective selections.
设计经验 发布时间 : 2024-05-01
Design Concepts for EMI/EMP Filter Connector
The heart of an EMI/RFI filter connector is the monolithic planar capacitor array. This is a barium-titanate ceramic disc, which provides a common substrate for capacitance on each line of a connector. The capacitance values can be mixed including ground and feed-thru lines.
设计经验 发布时间 : 2024-04-03
MDCX & MDHC Connectors
型号- 017300-3010,017300-3013,017317-1008,017317-1206,017317-1208,017317-2016,017317-1003,017300-2006,017300-3018,017317-1004,017317-2018,017317-1203,017300-2008,017317-1006,017317-1204,017300-2003,017300-3014,017317-2014,017300-2004,017317-2013,017300-3016,017317-3020,017317-2010,013114-2005,013114-2003,013114-2004,013109-2004,017317-2008,017300-3008,017317-2004,017317-3016,017317-2006,017317-3018,017300-3004,017317-3013,017300-3003,017317-1110,MCHC,017317-2003,017300-3006,017317-3014,017317-3010,013214-1002,013214-1001,013114-1001,013114-1002,013214-1003,013114-1003,017300-2020,017317-1106,017317-1108,017317-3006,017317-1103,017317-3008,017317-1104,017317-3004,017317-3003,013214-2003,013214-2005,013214-2004,MDCX,017300-2010,013209-2004,017300-3020,017300-2018,017300-2014,017317-1010,017300-2013,MDHC,017300-2016,017317-1210,017317-2020
Smiths Interconnect M23圆形电源连接器&信号连接器选型指南
描述- M23 Signal and Power Connectors in favour of motor drive applications. For the installation, crimp contacts are used which guarantee high quality of the connection, reducing the installation costs at the same time.Hand-operated and fully automatic crimping tools can be used to assemble the crimp contacts. There are two different Hypertac® hyperboloid contact types available: Machined and stamped.
型号- 020.263.1020,L□□□□□□□□□□□□□□□,C/BEL/1,B295/1.0-2.0,030.225.1000,030.701.2000,021.001008.1025,020.000376.2000,B157,021.101.2000,020.332.1020,B154,030.676.2000,030.631.2000,020.000377.2000,B150,020.001011.1020,B151,021.001009.1020,030.400.2000,030.629.2000,020.331.1020,020.315.1020,020.281.1020,021.001025.1020,021.415.1020,B286/28-24,020.000378.2000,030.617.2000,B202,020.232.2000,B201,B165,021.029.1020,B038A,030.677.2000,021.001007.1025,021.147.2000,060.030.2000,030.226.1000,030.704.2000,021.001005.102,030.635.2000,021.356.1020,020.105.1020,B179,B297,060.031.2000,SERIES L,030.387.2000,B287/28-24,SERIES S,030.679.2000,020.001001.2000,B295/0.5-1,021.382.1020,021.385.1020,B056A,B286/32-28,020.090.1020,030.619.2000,030.506.2000,B341,B288/28-24,C/BEL/7,B186,C/BEL/5,B295/2.5-4,021.129.1020,B118,B116,B287/32-28,B117,B230,030.637.2000,B286/0.75-1,B287/0.75-1,B190,030.623.2000,020.123.1020,B055/A,021.001017.1020,030.625.2000,B286/24-20,021.001018.1020,020.001002.2000,020.256.1020,B245,021.384.1020,021.165.1020,030.505.2000,021.001004.1020,030.504.2000,020.000379.2000,021.311.1020,021.072.1020,021.380.1020,031.001053.1000,B378,030.479.2000,B288/32-28,B132,021.310.1020,021.001006.1025,B252,021415.1020,B037A,B091,021.402.1020,B287/24-20,030.678.2000,B295/0.5-1.0,060.032.2000,060.029.2000,B305,B288/0.75-1,B306,S/DEM/6/0060,020.353.1020,030.691.2000,B288/24-20,030.627.2000,S/MONT/1/0060,030.697.2000,020.001003.2000,020.060.1020,030.621.2000,S□□□□□□□□□□□□□□□,021.279.1020
Smiths Interconnect Completes Product Offering for Disposable Healthcare Devices
Patient safety is a top priority for medical device makers. Their customers and the world of disposable medical devices are constantly evolving, due in large part to the risk and cost associated with reprocessing devices, compounded by growing regulations regarding the enviromental impact of disposable devices versus sterilization processes. To meet the market demand, Smiths Interconnect has developed a new disposable receptacle connector to complete its Hypergrip® Series of patented and proven high reliability circular connectors specifically designed for medical applications.
产品 发布时间 : 2024-10-11
LightCONEX CONEXPlug-in module and backplane connectors for VPX systemsPlug-in module and backplane connectors for VPX systems
型号- 450-00068,VITA 66.4,450-00064,450-00042,450-00065,450-00066,LCX12P418532101,VITA 67.3C,LCR12C418530301,LCX04A418532301,VITA 67.3E,LCR12C418530101,VITA 67.3D,LCX04A418532101,415-00019,LCR12C428530101,415-00018,LCT12B418533001,LCT12B428533001,LCX12B418532101,12TRX,LCR12A418530301,LCT12C418533001,LCT12C428533001,450-00062,LCX04B428532101,LCX04B418532101,LCR12A418530101,LCX04B418532301,LCR12B418530101,LCR12B418530301,LCR12B428530101,450-00054,LC 4TRX,LCT12A418533001,LCX12C418532101,12RX,LCX04C428532101,415-00035,12TX,415-00012,415-00011,LCX04C418532301,4TRX
Smiths Interconnect D系列快速断开圆形塑料连接器选型指南
目录- Quick disconnect circular plastic connectors
型号- T1124,T1982,T1981,T1164,D01,D00,D02,D02 SERIES,D00 SERIES,D01 SERIES,D SERIES,T1866,T1888,T2019,M22520/2-01,D00EEB-0001,T870,D02□□B905□□□□□□□U□□□,MINI D00,HX3,T1957,T1914,T1958,S/DEM5.0150,M309,AFM8,K623,K547,T1215,AF8,D01□□B□□□□□□□□□,K1775,T1271,S/DEM1.0060,T2080,TP688
Smiths Interconnect MHD/MDD/MDP系列PCB高密度连接器选型指南
描述- Smiths Interconnect offers an extensive range of superior contact technologies suitable for standard and custom solutions. Hypertac® (HYPERboloid conTACt) is the original superior performing hyperboloid contact technology designed for use in all applications and in harsh and demanding environments where high reliability and safety are critical.
型号- MHD 00- __ Z134,KMX 3-F 101,MHD 00- __ Z133,MHD 00- __ Z111,SD- 030 00 CX 003,MHD 00- __ Z130,MHD 00- __ Z131,KMX 3-M 092,KMX 3-F 142,KMX 3-F 032,MHD,MHD 00- __ 121,MDD SERIES,MHD 00- __ Z190,MHD 00- __ Z191,MDD,KMX 3-M 112,KMX 3-M 041,KMX 3-M 131,MHD 00- __ Z124,MDP,KMX 3-F 172,MHD SERIES,020 087 1- 30R OG,020 091 1- 40R OG,KMX 3-F 112,020 085 1- 10R OG,KMX 3-M 032,MHD 00- __ Z122,KMX 3-M 081,KMX 3-F 131,MHD 00- __ 110,KMX 3-M 101,MDP SERIES,KMX 3-M 142,KMX 3-M 172,020 084 2- 10R G1,KMX 3-F 041,020 056 2- 30R G1,KMX 3-F 081,MHD 00- __ Z125,MHD 00- __ Z126,020 060 2- 40R G1,KMX 3-F 092
Spring Probes Loose Probe & Connector Solutions
型号- 101111,305330-000,101190,101506,101628,101402-000,100410,100410-005,PI-5327,100891-002,100671,101628-000,101247-001,100671-000,100606-000,101050-003,PI-5329,101712-000,PI-5328,101119-001,101506-000,101190-002,101438-000,101111-008,101712,101679,101438,101119,101050,101294,100804-002,305327-000,305328-000,101050-005,101294-000,PI-5330,305329-000,101367,101247,101402,101602,102197,100891,100803-011,101679-000,101530-000,100803,100606,100804,101530,101367-001,101367-002
Smiths Interconnect 线缆组件选型指南
目录- Company and product introduction Cable Semi-Rigid/Conformable/Flexible Cable Semi-Rigid Low Loss Cable MIL-C-17/RG Series Cable LMR Cable Cable Assembly Options Cable Application Notes Cable Engineering Data Introduction
型号- RG405,402TP,RG401,LMR-240,RD316,RG402,405TP,SMS-RG142_-18.0-SMS±2.8PS,LMR-240-LLPL,LMR-400,250TP,LMR-400-LLPL,AL250LLTP,LMR-400-UF,LMR-100A-PVC,SF316,LMR-240-DB,AL141LLSP,BJ085,LMR-400-DB,142D,BJ141,LMR-195,RG316,KMS-AL141LLSP_-12.0-KMS±2.8PS,SF 142,LMR-240-UF,AL141TP,BJ047,SMS-BJ085-18.0-SMR±2.8PS,SMS_100_24.0-SMS_,AL085TP,RG223,316D,RG400,AL085LLSP,RG142
Smiths Interconnect Introduces Mini-Lock Connectors, New Technology to Improve Connectivity in Mission Critical Applications
Smiths Interconnect today announces the introduction of a new, cutting-edge product in its range of connectors that enables faster and more reliable connectivity across a range of mission critical industry sectors and applications.
产品 发布时间 : 2024-08-06
Smiths Interconnect New High-power Connectors for Demanding Defense Applications
Smiths Interconnect announced HBB five-pole connector in addition to the already existing single-pole version with a unique, quick latch mechanism. Smiths Interconnect announced HBB five-pole connector in addition to the already existing single-pole version with a unique, quick latch mechanism.
新产品 发布时间 : 2022-04-07
Cable Assembly PRODUCT CHANGE NOTICE (2024-SISZ-001)
型号- 010551# 0089,010551# 0092,010551# 0093,010551# 0094,010551# 0095,010551# 0096,010551# 3001,010551# 3003,010551# 0099,010551# 3002,010551# 0090,010551# 0091,010551# 3005,010551# 3004,010551# 3007,010551# 3006,010551# 3009,010551# 3008,010551# 0067,010551# 0068,010551# 0069,010551# 0070,010551# 0071,010551# 0072,010551# 0073,010247# 0349,010551# 0075,010551# 0076,010551# 0077,010551# 0078,010551# 0079,010551# 0081,010551# 0082,010551# 0083,010551# 0084,010551# 0085,010551# 0086,010551# 0087,010551# 0088,010551# 0080,010247# 0328,010247# 0325,010551# 0301,010551# 0001,010551# 0122,010551# 0243,010551# 0002,010551# 0123,010551# 0244,010551# 0003,010551# 0245,010551# 0004,010551# 0246,010551# 0005,010551# 0126,010551# 0247,010551# 0006,010551# 0127,010551# 0248,010551# 0007,010551# 0249,010551# 0008,010551# 0129,010551# 0250,010551# 0130,010551# 0251,010551# 0010,010551# 0131,010551# 0252,010551# 0011,010551# 0132,010551# 0253,010551# 0012,010551# 0133,010551# 0254,010551# 0013,010551# 0134,010551# 0255,010551# 0014,010551# 0135,010551# 0256,010551# 0015,010551# 0136,010551# 0257,010551# 0016,010551# 0258,010551# 0017,010551# 0259,010551# 0018,010551# 0139,010551# 0019,010551# 0260,010551# 0140,010551# 0261,010551# 0141,010551# 0262,010551# 0021,010551# 0263,010551# 0022,010551# 0264,010551# 0108,010551# 0109,010551# 0100,010551# 0101,010551# 0102,010551# 0103,010551# 0104,010551# 0105,010551# 0106,010551# 0107,010551# 0110,010551# 0119,010551# 0111,010551# 0112,010551# 0113,010551# 0115,010551# 0116,010551# 0117,010551# 0118,010551# 0120,010551# 0121,010551# 0242,010551# 0045,010551# 0046,010551# 0047,010551# 1015,010551# 0048,010551# 1016,010551# 0049,010551# 1017,010551# 1019,010551# 0050,010551# 0051,010551# 0052,010551# 1020,010551# 0053,010551# 0295,010551# 1021,010551# 0054,010551# 1022,010551# 0055,010551# 1023,010551# 0056,010551# 0057,010551# 0299,010551# 0058,010551# 0059,010551# 0060,010551# 0061,010551# 0062,010551# 0063,010551# 0064,010551# 0065,010551# 0066,010551# 2001,010551# 0023,010551# 0144,010551# 0265,010551# 0145,010551# 0266,010551# 0025,010551# 0267,010551# 0026,010551# 0268,010551# 0027,010551# 0269,010551# 0028,010551# 0029,010551# 0270,010551# 0271,010551# 0030,010551# 0272,010551# 0031,010551# 0273,010551# 0032,010551# 0274,010551# 0033,010551# 0275,010551# 0034,010551# 0276,010551# 0035,010551# 0277,010551# 0036,010551# 0278,010551# 0037,010551# 0279,010551# 0038,010551# 0039,010551# 0280,010551# 0281,010551# 0040,010551# 0282,010551# 0041,010551# 0283,010551# 0042,010551# 0284,010551# 0043,010551# 0044,010551# 0286,010551# 1012
Smiths Interconnect Launches Press-Fit cPCI Connector Series to Enhance Efficiency, and Reduce Costs
Smiths Interconnect is thrilled to announce the release of the Press-Fit version of its renowned cPCI connector series. This innovative addition underscores Smiths Interconnect’s dedication to meeting the rigorous demands of the Defense, Space and Commercial Aerospace markets.
产品 发布时间 : 2024-07-24
Smiths Interconnect KA系列符合MIL-DTL-55302标准的PCB连接器选型指南
目录- Hypertac® Hyperboloid Technology PCB Connector
型号- YPN006-020H,YPN006-072H,YPN006-016H,YPN006-016G,YPN006-024G,YPN006-036H,YPN006-036G,YPN006-048H,YPN006-024H,YPN006-020G,YSK006-090AH,YPN006-106H,YPN006-106G,YSK006-094AH,KA 160.4/127CEMY21TAH,YSK006-092AH,YSK006-014AH,KA □□□ □/□□□□ □ □□□ □ □□ □□□ □□□□ □□,YSK006-012AH,YPN006-172G,YPN006-075H,YPN006-172H,YSK006-029AH,YPN006-015G,YPN006-487H,YPN006-148H,YPN006-148G,YPN006-039H,YPN006-035G,YSK006-096ANH,YPN006-015H,YPN006-023H,YPN006-023G,YPN006-035H,KA 160.4/127CEMD21TAH,YSK006-006AH,KA 160 / 127 C P M C 10 TH,YPN006-050H,YPN006-171H,YPN006-470H,YPN006-171G,YPN006-470G,KA SERIES,YPN006-159H,YPN006-159G,YPN006-022G,YPN006-034H,YPN006-034G,YPN006-022H,YPN006-019G,YPN006-039G,KA 160.4/127CEFD21TAH,YPN006-019H,YSK006-030AH,KA 17 / 127 BE F C 21 TAH,YSK006-010ANH,YSK006-013AH,YSK006-074AH,YSK006-274AH,YPN006-073H,YSK006-028AH,YPN006-049H,YPN006-021H,YPN006-021G,YPN006-077H,KA 160.4/127CEFY21TAH,YSK006-009AH,YSK006-005ANH(2),YSK006-011ANH,YSK006-020AH,KA 17 / 127 BP M C 10 TH
电子商城
品牌:华丰史密斯
品类:Environmentally-Sealed Rectangular Plastic Connectors
价格:¥253.5117
现货: 10
现货市场
登录 | 立即注册
提交评论