Air Cooled VCSEL Applications with Rogers Micro-Channel-Coolers (MCC)

2022-02-08 Rogers

“When air-cooled heat sinks cannot cope with too high power densities, liquid-cooled cold plates are the heat transfer solution of choice.” [1]


Reading this statement got me thinking: How would ROGERSMicro-Channel-Coolers (MCCs) perform in air cooling applications? Rogers'MCCs have only been used for liquid cooling; however, customers´ heat management challenges in new VCSEL (vertical-cavity surface-emitting laser) applications are reaching new levels, and several active-cooled approaches are being tested. For our partners, the challenge for moving to liquid cooling is that it is both risky [2], and the cost and maintenance increase while passive/standard air-cooling options might not be able to solve the thermal problem. For that reason, we started testing and evaluating Rogers'MCCs with compressed air as a coolant. As a result, different micro-channel designs have been benchmarked with standard macro-channel heat sinks.


Theses to test:

Rogers'MCCs can achieve a better cooling performance vs. off-the-shelf Macro-Channel cold plates at lower flow rates.

Qua 50 will be the best performing Rogers’ standard MCC structure.


Simulation and conditions

We performed simulations with SolidWorks Flow Simulation 2020 based on the conditions mentioned below, shown in fig. 1. For all thermal CFD simulations of the cooling structure, we applied the inlet and outlet configuration depicted in fig. 2. Unless stated otherwise, we kept the cooler area, as well as the chip position, constant for all simulations and comparisons. The cooler is comprised of four individually structured copper layers with a thickness of 200 µm each. The first layer acts as cover. The following two copper layers form the cooling channel. The last copper layer forms the backside cover, see fig. 3.

Fig 1: Boundary conditions for the test


Fig. 2: Configuration of an inlet, outlet and a chip on cooling structure

Fig. 3: Top and cross-section view of a cooling structure

To run the simulations, we used three different cooling structures. Type 1 corresponds to Rogers’ Qua 50 structure and type 2 corresponds to a Qua 100 shown in fig. 4. It should be noted that Qua 50 uses 50% smaller geometries than Qua 100. Compared to these, we used a Hex 50 (type 3) and two standard lamellar coolers with five channels in the size 0.5mm x 0.4mm (type 4) and three channels in the size 1.00mm x 0.4mm (type 5), all shown in fig. 5.


Fig. 4: Left to right: Schematic fluid flow through a cooling structure; Detail of a Hex 100 and Qua 100 inner cooling structure


Fig. 5: Top view on cooling structures, five different types are shown


Results and Discussion

Fig. 6 shows the flow velocity distribution of type 1 and type 4. We can clearly seen that in the channels of type 4, laminar flow is dominate while the cooling structure of type 1 supports a turbulent flow. This, in combination with a larger effective cooling area of type 1, leads to a higher heat transfer coefficient at the same flow rate, depicted in fig. 7. Here, the cooling structure type 1 has the highest heat transfer coefficient at the same flow rate. The smaller cooling structure of type 1, 2 and 3 also leads to a faster increase of the pressure on the inlet compared to type 4 and 5, shown in fig. 8.

Fig. 6: Top view on cooling structures, five different types are shown


Fig. 7: Heat transfer coefficient vs. flow rate

Fig. 8: Air pressure vs. flow rate


Improved performance in comparison with competition comes from a higher specific surface area, as well as a maintained turbulent flow. For certain areas of application, air cooling can be superior to water cooling due to its simple availability, despite the worse thermal performance of air itself. Likewise, liquids are not often used in electronics due to the risk of leaks. Assuming, compressed air up to 90psi is relatively common and available at manufacturing locations, Rogers’ Type 1 micro-channel structure realizes about 50% lower operating costs versus cooler type 4 and 5. Calculating with 7.000 working hours per year times 0,02€ m³/h this accounts for 140€/year less per unit.


Our next steps are to confirm simulation results through tests carried out on our test bench and in customer applications. Another target is to also optimize cooling structures for air cooling use cases to improve performance and cost. 


授权代理商:世强先进(深圳)科技股份有限公司
技术资料,数据手册,3D模型库,原理图,PCB封装文件,选型指南来源平台:世强硬创平台www.sekorm.com
现货商城,价格查询,交期查询,订货,现货采购,在线购买,样品申请渠道:世强硬创平台电子商城www.sekorm.com/supply/
概念,方案,设计,选型,BOM优化,FAE技术支持,样品,加工定制,测试,量产供应服务提供:世强硬创平台www.sekorm.com
集成电路,电子元件,电子材料,电气自动化,电机,仪器全品类供应:世强硬创平台www.sekorm.com
  • +1 赞 0
  • 收藏
  • 评论 0

本文由翊翊所思转载自Rogers,原文标题为:Air Cooled VCSEL Applications with Rogers Micro-Channel-Coolers (MCC),本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。

相关研发服务和供应服务

评论

   |   

提交评论

全部评论(0

暂无评论

相关推荐

ROGERS层压板/高频板选型表

罗杰斯/ROGERS提供以下技术参数的层压板/高频板选型,超低损耗,低至0.0004(Df) ;超大尺寸:54inchX24inch、52inchX40inch、50.1inchX110inch 等;丰富介电常数:2 -12.85 (Dk);超薄介质,低至1mil

产品型号
品类
产品系列
介电常数(Dk)
正切角损耗(Df)
介质厚度(mm)(mil)
导热系数W/(m·K)
铜箔类型
铜箔1厚度
铜箔2厚度
尺寸(inch)
5880LZNS 24X18 H1/H1 R4 0100+-001/DI
层压板
RT/duroid® 5880LZ
2
0.0027
0.254mm(10mil)
0.33
电解铜
H1
H1
24X18

选型表  -  ROGERS 立即选型

ROGERS 半固化片选型表

罗杰斯/ROGERS提供以下技术参数的半固化片选型,超低损耗,介电常数(Dk):2.28-10.02,正切角损耗(Df):0.002-11.2,超大尺寸:24inchX36inch 、25.5inchX18inch、48inchX36inch等,超薄介质。

产品型号
品类
产品系列
介电常数(Dk)
正切角损耗(Df)
厚度(mils)(mm)(μm)
尺寸(inch)
导热系数W/(m·K)
3003 BOND PLY 25.5X18 005 R3
半固化片
RO3003
3.00±0.04
3
0.005” (0.13mm)
25.5X18
0.5

选型表  -  ROGERS 立即选型

Rogers苏州工厂生产的产品的临时交货期延长

描述- Rogers公司宣布,由于近期需求激增,其苏州工厂生产的多个产品将临时延长交货期。预计这种影响将是短期性的,并计划从2024年5月初开始逐步减少交货期。具体产品及其新的交货期已附在邮件中。公司正在评估现有订单的恢复日期,并请求客户提供预测信息以协助决策。

型号- RO4830™,RO4535™,KAPPA® 438,DICLAD880™,RO4533™,RO4000™,DICLAD®,RO3003G2™,RO3035™,RO3003™,RO4003C™,RO4835™,RO3003G2™ PM,TC350™,RO4534™,RO4730G3™ R2,RO4835T™,RO4233™,RO4350B™,RO3006™,AD255™,AD300™,RO3010™,RO3000™,TC350™ PLUS

April 9th, 2024  - ROGERS  - 产品变更通知及停产信息 代理服务 技术支持 批量订货

【经验】如何选择合适介电常数的Rogers高频板材?

在选择板材rogers高频板材时,最关注的指标是介电常数。但也有一部分工程师对介电常数理解的比较片面,在选择rogers高频板材时,会遇到一些问题,通过本文讲解,可以更好的帮助工程师快速准确的选择合适介电常数的板材。介电常数和频率相关,同一种板材的不同厚度有时会有一定差异。rogers板材的范围1.96(RT/duriod 5880LZ)-13(TMM13i)。

2018-08-19 -  设计经验 代理服务 技术支持 批量订货

Rogers苏州工厂碳足迹减排项目的计划停工时间

描述- Rogers苏州工厂计划于2024年3月11日至3月16日进行升级改造,期间将暂停生产,影响交货期。此次停工旨在实施碳减排项目,符合公司全球ESG目标。改造完成后,预计交货期将恢复至项目前水平。公司正努力提前完成订单,并请求客户提前下单。

March 1st, 2024  - ROGERS  - 产品变更通知及停产信息 代理服务 技术支持 批量订货

Rogers高频板RO4350B板材在24GHz时介电常数和损耗因子

Rogers高频板RO4350B达到了成本和高频性能的最优化,是最具性价比的低损耗高频板材。为了更好的实现设计要求,笔者在设计微带阵列天线时研究了基于Rogers高频板RO4350B板材的微带传输线在24GHz的插入损耗。

2024-04-29 -  设计经验

Rogers Corporation主动承担降低RO3000®产品线供应链的风险

描述- Rogers Corporation为提高RO3000®产品线的供应链韧性,与多个PTFE树脂供应商合作,确保材料供应的持续可靠性。由于供应商退出,部分产品将更换PTFE供应商。从2023年9月开始,RO3000®层压板客户将逐步过渡到RO3010™,预计2024年第一季度末完成。Rogers已对新产品进行测试,并与现有产品进行对比,分析表明两者性能无显著差异。

型号- RO3006™,RO3003G2™,RO3210™,RO3206™,RO3035™,RO3003™,RO3000®,RO3203™,RO3010™

June 26, 2023  - ROGERS  - 产品变更通知及停产信息 代理服务 技术支持 批量订货

ROGERS 粘结膜选型表

ROGERS 粘结膜选型:介电常数(Dk):2.32-2.35,正切角损耗(Df):0.0013-0.0025,Lengths(ft):30ft-150ft,熔化温度(℃):397°F (203°C),多种尺寸:12X18/24X18/24X30等。

产品型号
品类
产品系列
介电常数(Dk)
正切角损耗(Df)
Lengths(ft)
熔化温度(℃)
尺寸(inch)
厚度(mm)
6700 2.35 24X30LFX0.003
粘结膜
CuClad 6700
2.35
0.0025
30ft
397°F (203°C)
24X30
0.0030" (0.08mm)

选型表  -  ROGERS 立即选型

Rogers(罗杰斯) MWI计算工具(2018版)

描述- 本资料以压缩包的形式呈现,包内附有Rogers(罗杰斯) MWI计算工具(2018版)软件。

ROGERS  - 开发环境(软件/固件) 代理服务 技术支持 批量订货

Rogers RT6010LM, DK是否有=11.2的材料

ROGERS的RT6010系列高频板材曾经有三个型号,6010.2LM、6010.5LM以及6010.8LM但是后两者陆续停产,现在推荐使用6010.2LM,该型号没有DK为11,2的,具体资料见:Rogers(罗杰斯) RT/duroid 6006/6010LM 高性能板材数据手册

2019-07-31 -  技术问答
2022/11/28  - ROGERS  - 成功案例 代理服务 技术支持 批量订货

ROGERS微波板材5880 18X12 5R/5R R3 0310+-001/DI的5R是什么意思?

根据rogers铜箔名称查询,ROGERS微波板材5880 18X12 5R/5R R3 0310+-001/DI的5R表示0.5OZ的压延铜箔。

2019-05-28 -  技术问答

Rogers RO4350B板材的Dk是用什麼测试方法?求详细介紹

Rogers的4350板材的DK测试 可以参照IPC-TM-650 2.5.5.5和 IPC-TM-650 2.5.5.6

2018-06-29 -  技术问答

Rogers Announces Termination of Merger Agreement with DuPont

Rogers announced the termination of its definitive merger agreement with DuPont de Nemours, Inc. (“DuPont”). In connection with the termination of the merger agreement, Rogers has received a regulatory termination fee of $162.5 million from DuPont.

2022-11-08 -  原厂动态 代理服务 技术支持 批量订货
展开更多

电子商城

查看更多

品牌:ROGERS

品类:Circuit Materials

价格:¥2,479.9453

现货: 1,289

品牌:ROGERS

品类:High Frequency Circuit Materials

价格:¥550.8681

现货: 1,135

品牌:ROGERS

品类:Antenna Grade Laminates

价格:¥2,989.4355

现货: 429

品牌:ROGERS

品类:Liquid Crystalline Polymer Circuit Material

价格:¥1,485.0299

现货: 253

品牌:ROGERS

品类:Antenna Grade Laminates

价格:¥2,571.9097

现货: 250

品牌:ROGERS

品类:High Frequency Circuit Materials

价格:¥2,669.6313

现货: 250

品牌:ROGERS

品类:Laminates

价格:¥1,452.6209

现货: 250

品牌:ROGERS

品类:High Frequency Circuit Materials

价格:¥554.2134

现货: 244

品牌:ROGERS

品类:PTFE/Woven Fiberglass Laminates

价格:¥16,030.1502

现货: 201

品牌:ROGERS

品类:High Frequency Circuit Materials

价格:¥4,679.1859

现货: 180

现货市场

查看更多

暂无此商品

海量正品紧缺物料,超低价格,限量库存搜索料号

服务

查看更多

散热方案设计

使用FloTHERM和Smart CFD软件,提供前期热仿真模拟、结构设计调整建议、中期样品测试和后期生产供应的一站式服务,热仿真技术团队专业指导。

实验室地址: 深圳 提交需求>

PCB快板打样定制

可加工PCB层数:1-30层;板材类型:FR4板/铝基板/铜基板/刚扰结合板/FPC板/高精密板/Rogers高频板;成品尺寸:5*5mm~53*84cm;板厚:0.1~5.0mm。

最小起订量: 1 提交需求>

查看更多

授权代理品牌:接插件及结构件

查看更多

授权代理品牌:部件、组件及配件

查看更多

授权代理品牌:电源及模块

查看更多

授权代理品牌:电子材料

查看更多

授权代理品牌:仪器仪表及测试配组件

查看更多

授权代理品牌:电工工具及材料

查看更多

授权代理品牌:机械电子元件

查看更多

授权代理品牌:加工与定制

世强和原厂的技术专家将在一个工作日内解答,帮助您快速完成研发及采购。
我要提问

954668/400-830-1766(工作日 9:00-18:00)

service@sekorm.com

研发客服
商务客服
服务热线

联系我们

954668/400-830-1766(工作日 9:00-18:00)

service@sekorm.com

投诉与建议

E-mail:claim@sekorm.com

商务合作

E-mail:contact@sekorm.com

收藏
收藏当前页面