Serial to Ethernet server enables traditional RS232/422/485 devices to be connected to the Internet immediately. It is widely used in factory automation, POS system, building automation systems, self-service banking systems, telecommunication room monitoring, power monitoring, and other fields. Nowadays, the technology of Serial to Ethernet servers is relatively mature, and there are many domestic manufacturers of Serial to Ethernet servers, but the quality and price are uneven. Many enterprises do not fully consider the environment of the project application site when choosing and purchasing, which leads to various unstable phenomena in the use process and increases unnecessary maintenance costs. So, how to avoid pitfalls in the selection of a Serial to Ethernet server?
1. Equipment fails to work normally in outdoor extreme environment
The lowest temperature in winter in the north of the Yellow River, Northwest China, and Northeast China is tens of degrees below zero, while the outdoor temperature in summer in some provinces of South and East China is very high. In this case, you will find that the Serial to Ethernet server bought online often has problems in use or its service life is greatly reduced due to saline-alkali, temperature, static electricity, and other reasons. An industrial Serial to Ethernet server, on the other hand, can operate stably in harsh field environments, and its industrial design ensures that its internal components will not age rapidly under the influence of the environment.
2. The power supply is not guaranteed, the voltage fluctuation is large, and the equipment is often shut down or damaged.
At present, although the residential power voltage in our country is very stable, in many industrial sites, because the power supply voltage can not be fully guaranteed, the voltage fluctuation is large, for example, 220V AC directly drops to 100V; 24V DC fluctuates between 12 ~ 48V. In this case, the equipment is prone to shutdown or damage. When choosing a Serial to Ethernet server, it is better to choose a Serial to Ethernet server that supports wide voltage. After all, in the industrial field, even a minute of downtime will cause great economic losses. Most of the designs of Serial to Ethernet servers adopt the design of wide temperature and wide voltage, which is only to adapt to more industrial sites and provide reliable functions for stable data transmission
3. The end-to-end data transmission delay of the virtual serial port function is high, resulting in untimely data acquisition.
Many enterprises have purchased equipment from non-professional manufacturers. After configuration and installation, it is found that when using the virtual serial port function, the data transferred from the serial port to Ethernet is often not collected in time, or even lost, which has an impact on field applications and losses. The reason for this problem is that the data stays in the Ethernet protocol stack for too long to achieve end-to-end transmission with low latency. In the final analysis, Serial to Ethernet server manufacturers have insufficient technical accumulation in product software. These problems are fatal in some applications of factory automation.PUSR uses the watchdog protection mechanism Serial to Ethernet server to achieve 24 hours without downtime.
Six debugging tips for Serial to Ethernet server
1. How to configure the serial server?
Before you use Terminal Server, you must configure the parameters according to your operating environment and application requirements before you connect and use the system. These parameters mainly include network parameters, the operation mode of each serial port, print service, management information of the device itself, and other contents.
2. How to set the serial port properties of the serial server, such as the baud rate?
On the Setup screen, enter the program settings, select the program, and then enter the serial parameters.
3. Why is data lost when using the virtual serial port to transfer files?
At this point, the virtual program loses data, mainly because the virtual serial port program completes the data faster and the serial port sends itself slowly while the virtual program sends the data to the remote device. The "analog baud rate" can be set in the virtual program.
4. Serial port self-test
Serial port self-test is a common method to detect whether the serial port is good or not. Connect pins 2 and 3 and manually send one (or more) bytes using the Serial Debug Assistant. If the reception area can receive the same bytes, the serial port is good and working; Otherwise, there is a problem with the serial port. With the addition of a serial server, this method can still be applied regardless of the cross or direct connection.
5. Serial port test simulation
For serial port testing, a computer can be used to simulate a device, but it does not have to be a real device. You can also simulate the baud rate and try other serial debugging assistants. There is a problem with one of the serial debug assistants. For example, a message that a serial port is occupied is not the same as a serial port problem. Debugging Assistant can also be a software problem. At this point, you can try to change the software.
6. Two ways to use a serial port server
Virtual serial port and IP form.
Note: The two methods are basically equivalent, but if one fails to connect, you can try the other. That is, the monitoring software may only support one or the other.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由成长的人生转载自usr News,原文标题为:How to avoid pitfalls in the selection of Serial to Ethernet server,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
What are the advantages of networking Serial to Ethernet server
This Serial to Ethernet server, to put it bluntly, is a transit station that provides passive data transmission, and through its own connectivity, it can connect to the Web server and serial port of the computer at the same time.
What Are the Common Abnormal Situations of Serial to Ethernet Server
Serial to Ethernet server is like a microcomputer with a CPU, real-time operating system, and TCP/IP protocol, which is convenient for data transmission between serial ports and network devices.
Applications and Advantages of Serial to Ethernet Adapter in Modbus Communication
The application and advantages of Serial to Ethernet Adapter in Modbus communication are quite remarkable. For traditional industries, introducing Serial to Ethernet Adapter can not only enhance automation levels but also reduce maintenance costs and improve production efficiency.
Application of Remote Monitoring in Sewage Treatment Based on ethernet to serial converter
How to improve the efficiency of sewage treatment and reducing environmental pollution has become a problem that city managers need to solve. The remote monitoring application scheme of sewage treatment based on serial to ethernet server emerges as the times require.
有人物联(usr)以太网系列产品选型指南
目录- 公司简介和主营产品概览 串口服务器 Wi-Fi 串口服务器 以太网模块 工业级以太网交换机 数据采集网关系列
型号- USR-W600,USR-K7,USR-K6,USR-N510,USR-CANET200,USR-TCP232-T2,USR-SDR080,USR-SDR160,USR-SDR041,USR-M511,USR-SDR021,USR-N668,USR-TCP232-ED2,USR-TCP232-E2,USR-N540,USR-N520,USR-N580,USR-W630,USR-W610,USR-TCP232-S2,USR-SDR050,USR-TCP232-306,USR-TCP232-410S,USR-TCP232-304,USR-TCP232-302
打破远程运维边界,有人物联异地组网方案彻底解决终端设备无法统一远程管理痛点
现在,只需将这些终端设备连接在有人物联路由器网口下,通过异地组网平台简单配置,就能轻松搭建起一个终端互通的网络。企业总部人员或外出员工借助手机、PC随时随地对终端进行远程调试、下载程序、配置等运维操作,彻底解决终端设备无法统一远程管理的痛点。
鼎桥CEO莅临有人物联参观交流,深化5G战略合作
在数字化转型浪潮的推动下,物联网技术的融合创新成为推动工业产业升级的关键力量。近日,行业领先的物联网解决方案服务提供商——有人物联,与享誉全球的通信解决方案供应商鼎桥通信技术有限公司,正式签署战略合作框架协议。此次合作不仅标志着双方在5G RedCap工业通信领域达成战略合作,也预示着双方共同推动物联网技术与产业的深度融合的坚定决心。
有人物联网双网口8串口的串口服务器USR-N580,独特的工业功能支持,支持Modbus网关功能
为了能为客户降低成本和减少布线难度,有人物联网研发出了一款双网口8串口的串口服务器,专门应用于多设备联网的复杂环境。八串口服务器USR-N580,是用来将TCP/UDP数据包与RS485接口实现数据透明传输的设备。 独特的工业功能支持,支持Modbus网关功能,更加方便工业现场使用。 支持网络打印,打印机行业使用更加方便。
水利应用全场景揭秘,有人物联响应时代号召,打造行业产品新高度
有人物联响应时代号召,深研水利行业应用十大场景,围绕智慧水利、智慧灌区、高标准农田、水库大坝安全监测、测控一体化闸门等核心板块,提供完整完善的有人水利行业产品组合。
【选型】有人物联WiFi6工业无线客户端、小体积5G工业数传终端满足AGV小车联网需求,确保通信稳定
AGV小车要不断移动就要依靠稳定的无线通信网络覆盖,以及快速的AP间漫游切换,保证各工业场景中AGV的高效稳定工作。AGV无线通信组网系统要具备较大带宽,支持实时双向通信,能够承载诸如高清视频、机器人/车辆运行数据、传感器数据、语音及其他网络业务。有人物联新推出的WiFi6工业无线客户端W660和小体积5G工业数传终端G815可助力AGV+物联网推动各行各业数字化转型升级。
有人物联网基于DTU实现远程自动抄表应用接入、数据管理和分析、远程控制等功能
基于DTU实现远程自动抄表应用方案,可以大大提高抄表的效率和准确性,同时降低企业的管理成本。随着物联网技术的不断发展,基于DTU实现远程自动抄表应用方案也将不断升级和完善,为企业管理提供更加强大的支持。
【电气】有人物联白金系列工业级交换机,工业防雷6000V,专为严苛工业环境设计
白金系列是有人物联推出的5口/8口、百兆/千兆工业级以太网交换机,专为严苛工业环境而设计。满足轨道交通、平安城市、智能交通、安防监控和其他恶劣环境中的部署要求,为用户的以太网设备提供可靠、便捷的联网解决方案。
有人物联网关/模组选型表
有人物联选型表如下参数:工作电压(V):3.0V-58V,工作电流(mA):22mA-170mA@5V/3.3V,工作温度(℃):-20℃ ~ +85℃,串口波特率(bps):300bps~1Mbps
产品型号
|
品类
|
工作电压(V)
|
工作电流(mA)
|
工作温度(℃)
|
USR-G776
|
网关
|
9V~36V
|
72mA@12V
|
-25℃- 75℃
|
选型表 - 有人物联 立即选型
有人物联随身上网宝,最新支持机型&激活教程
很多朋友时常觉得手机流量不够用,流量加油包太贵不划算;又或是为外出工作、旅行WiFi不给力而苦恼,有人全新推出省话费&随身网络“神器”——随身上网宝,包年无限流量随便刷,支持手机、电脑、平板多种设备,小巧便携、即插即用、费用划算,分分钟实现网络自由!
电子商城
登录 | 立即注册
提交评论