Laird Thermal Systems Introduces 5000Watt Heat Exchanger for Industrial Applications
The LA5000 Series recirculating liquid-to-air Heat Exchanger offers improved thermal performance maximizing system uptime.
June 6, 2022 – Laird Thermal Systems has expanded its line of water heat exchangers with the introduction of the LA5000 Liquid Cooling System. As a water heat exchanger, the 5000-watt unit offers dependable compact performance while removing large amounts of heat from a liquid circuit. Designed to maximize system uptime, the LA5000 heat exchanger is ideal for immersion cooling and bulk heat removal in particle accelerators, linear accelerators, cyclotrons, semiconductor fabrication equipment, medical X-ray, and industrial X-ray scanners.
Fig.1
The LA5000 is designed to operate above ambient temperatures, eliminating the threat of condensation. The system operates full-time, continually monitoring system liquid levels and notifying users of preventative maintenance to avoid costly failure. A dedicated tank prevents air entrapment within the liquid, stopping air bubbles from getting drawn into the liquid and damaging the pump. The added instrumentation results in a more robust design, and with proper care and maintenance, users can expect over 10,000 hours of continuous, maintenance-free operation.
For improved thermal performance, the LA5000 cooling system uses a higher-performing heat exchanger and a more efficient fan, reducing operating noise and the temperature difference between the liquid and the air by a factor of 2. Coolant is recirculated using a high-pressure pump to ensure maximum flow rate over a wide operating range. The heat from the coolant is dissipated to the surrounding environment using a heat exchanger and fan. Compared to standard liquid chillers that operate below ambient temperatures, the LA5000 liquid cooling system operates above ambient temperatures, at a lower cost. The robust yet compact system is UL Recognized by IEC standards.
“The high reliability and simplicity of this cooling system make it an ideal selection for many industrial applications in need of cooling”, says Greg Ducharme, Product Director at Laird Thermal Systems. “At one-fourth of the cost of a liquid chiller, you would be hard-pressed to find a system this small and quiet that is capable of this high thermal performance.”
- |
- +1 赞 0
- 收藏
- 评论 0
本文由三年不鸣转载自Laird Thermal Systems News,原文标题为:Laird Thermal Systems Introduces 5000 Watt Heat Exchanger for Industrial Applications,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
Nextreme™ Value Chiller Family Provides Economical Cooling Solution for Manufacturers of Medical, Industrial and Analytical Equipment
Laird Thermal Systems Nextreme™ Value Chiller Series of recirculating chillers are now available in 1200Watt and 4500Watt options. It is a reliable, cost-effective cooling solution for medical, industrial, and analytical equipment.
Laird Thermal Systems Unveils Micro Multistage Thermoelectric Cooler & Optical TEAs Integration Capability
“Advanced process automation has enabled a new level of miniaturization for our MSX multistage series to support next-generation imaging solutions that require smaller optical packages,” said Andrew Dereka, Thermoelectrics Product Director at Laird Thermal Systems.
莱尔德热系统推出新一代5000W液体-空气水热交换器LA5000,可延长浸入式冷却系统的正常运行时间
莱尔德热系统公司的LA5000是一种5000W的液体-空气水热交换器,其设计工作温度略高于环境温度,能够为系统冷凝器提供极好的冷水来源,因此是浸入式冷却应用的理想选择。
Laird Thermal Systems Produces a Wide Array of Thermoelectric Coolers, Assemblies and Temperature Controller Combinations Optimized for Incubator Chambers
Laird Thermal Systems introduces thermoelectric solutions for incubator chambers, emphasizing precise temperature control without refrigerants. The HiTemp ETX Series and SuperCool X Series provide efficient heating and cooling, crucial for cell culture in labs. These systems offer a compact, reliable, and low-maintenance alternative to traditional incubator thermal management.
【产品】5000W水热交换器LA5000系列,使用更高性能的热交换器和更高效的风扇,是冷却工业应用的理想选择
莱尔德热系统推出LA5000液冷系统,扩展了其水热交换器产品线。这款5000W的水热交换器紧凑且性能可靠,可以从液体回路中带走大量的热量。LA5000热交换器旨在最大化系统的正常运行时间。
Laird Thermal Systems Launches the SuperCool X Series with Next-Gen Thermoelectric Cooling Technology
Laird Thermal Systems has launched a new high-performance thermoelectric cooler assembly series that utilizes next-generation thermoelectric coolers with advanced semiconductor materials. This enhancement boosts cooling performance by up to 10% over previous models.
What are the benefits of using liquid instead of air cooling systems?
Liquid heat exchangers can reduce the thermal resistance of conventional heat sink fan dissipation mechanisms by a factor of 10 or more, which makes it much more efficient. This is due to the poor thermal properties of air versus coolants such as water. Liquid cooling systems have a more rapid cool down time, which means less time to reach the desired temperature. While conventional air cooling systems push air all around the system, and can potentially add heat from surrounding hot electronics, liquid cooling systems are equipped with a heat exchanger that routes heat away through a liquid circuit. Air-cooling systems in the higher capacity range often require larger fans, which can increase noise as well as the size of the system.
How reliable is Thermoelectric cooling?
Thermoelectric coolers are highly reliable because they have a solid-state construction with no moving parts. They are also known for having a high mean time between failures (MTBFs). It is difficult to estimate the lifetime of a thermoelectric cooler, due to the variables in application conditions such as changes to heat load, on/off cycling, heat or cooling, drive circuit and system design with protection against condensation. All variables can influence the product’s lifetime. However, for demanding applications such as modern diagnostic, which require high rates of thermal cycling, the PowerCycling PCX Series thermoelectric coolers have been tested to withstand rigorous cycle testing based on latest PCR industry test protocol without degradation in performance.
Laird Thermal Systems‘ Nextreme™ Value Chillers Provide Economical, High Reliability OEM Cooling Solution
The Extreme Value Chiller Series uses high-performance components to cool well below ambient temperatures to control processes or dissipate heat away from thermally sensitive equipment.
Laird Thermal Systems Offers Thermoelectric Coolers, Thermoelectric Cooler Assemblies and Temperature Controllers for Refrigerated Centrifuges
Centrifuges are crucial for separating mixtures in medical and food processing labs. They face thermal challenges like temperature stability and noise levels. Thermoelectric coolers, like those from Laird Thermal Systems, offer an efficient and reliable solution for precise temperature control in centrifuges, reducing power consumption and maintenance costs. Laird‘s CP Series and temperature controllers provide stable cooling capacities and accurate control, making them ideal for various centrifuge applications.
High-performance Thermoelectric Coolers Offer A Flexible Active Cooling Option for Spot Cooling of Lidar Sensors
The lasers in Lidar systems, particularly those used in outdoor autonomous applications, require active cooling to achieve maximum resolution in high-temperature environments. As temperatures increase, the wavelength of the laser changes, resulting in increased range error. Maintaining operational temperatures within a Lidar system’s temperature limits ensures peak performance. Laird Thermal Systems High-performance thermoelectric coolers offer a flexible active cooling option for spot cooling of Lidar sensors.
Laird Thermal Systems‘ Next Generation Heat Exchanger LA5000 Economically Provides Full-Time Operation for Immersion Cooling in Data Centers
Laird Thermal Systems’ LA5000 is a 5000-watt liquid-to-air water heat exchanger designed to operate slightly above ambient temperatures serves as an excellent source of cold water for the system condenser and is ideal for immersion cooling applications.