Coolant Distribution Units - Improve Cooling and Performance of Cloud, Enterprise & 5G Applications
Boyd Corporation has been the leading innovator in Enterprise cooling and engineered material solutions since data centers first started to emerge and evolve. Boyd utilizes these decades of expertise to develop advanced thermal solutions and systems to stay ahead of rapidly rising processing power, thermal density, and heat loads. This includes forward-thinking liquid cooling innovation and system components such as Coolant Distribution Units (CDUs). This article covers CDU technology for improved liquid cooling systems and integrated solutions that help OEMs increase compute density in the same footprint, iterate designs quickly and accelerate speed to market, increase efficiency and reliability, and lower the total cost of data center ownership with a scalable thermal management plan that outpaces processing power and application requirements.
TRENDS IN THERMAL MANAGEMENT FOR ENTERPRISE & 5G
There has been a sharp rise in global digitalization and electronification across all major industries as smart technology innovation, processing ability, and technology reliance are increasing exponentially. Consumers require faster connectivity, more information, and improved functionality across all markets. This is driving the need for larger, more efficient data centers with faster, more powerful chips to support cloud and edge computing as well as increased processing and storage. One of the most significant barriers to technological advancement and improved processing for these data centers is managing the excess heat generated by the increase in data and storage as well as power generation and supply.
New, higher power applications require more efficient cooling for high heat loads in compact volumes; this typically leads engineers to turn to liquid cooling solutions. Design engineers have creatively driven air cooling innovation to impressive performance levels for product design teams reticent about introducing liquid cooling into high-reliability data center systems. However, new requirements are making it increasingly difficult to avoid liquid entirely. Overlapping technology portfolios enable liquid, immersion, two-phase, and air cooling innovation to co-exist, allowing engineers to blend the right solutions for each customized application to extend the performance boundaries of traditional air cooling systems and assure a safe migration to liquid cooling systems when appropriate. Thermal and power density demands of next-generation designs have now reached air cooling limitations, requiring the transition to liquid. The liquid is much more efficient and has the capacity to transfer heat up to 4X higher than the capacity of forced air of the same mass. This enables faster, more cost-efficient, quieter, better-performing applications through efficient, improved heat transfer and higher thermal performance with increased design flexibility and scalability. Increased efficiency and smaller systems also save space, allowing for more racks and servers operating at higher performances.
Data Center Racks
A liquid-cooled system is a hydraulic circuit that typically consists of a cold plate that interfaces with a heat source in a device, hoses, and pumps that circulate fluid through the system, and a heat exchanger that rejects heat into the ambient environment. Liquid-cooled systems are becoming much more common as air cooling is unable to handle new, higher heat loads, and liquid cooling reliability is proven through many hours of in-field installations with leak-free performance. CDUs are the core of liquid systems and are designed to increase overall system efficiency and reduce the total cost of ownership for the data center.
WHAT'S NEXT?
Processing and data storage needs will continue to increase exponentially as organizations and individuals further demand digitalization, greater functionality, increased speed and service, better connectivity, and more electronification globally. To support this global trend, data centers and enterprise applications need to be larger, more efficient and operating 24/7 with improved processing and storage efficiency. This will, in turn, generate greater thermal density and higher heat loads as never seen before in Enterprise Technologies. Data Centers will need to adapt their thermal management strategy quickly to accommodate the fast-changing landscape and increased heat. Liquid Cooling Systems and CDUs will play a big part in these new strategies.
With decades of innovation expertise, experience, and supplier partnerships, coupled with the unique approach of integrating multiple technologies into a streamlined product, Boyd Corporation will continue to stay at the forefront of innovation and improved manufacturing that offers unsurpassed reliability and performance while lowering overall costs to the data center operator. If you are looking to solve current issues or tackle new challenges for the next generation, start by contacting Boyd Corporation to learn more about engineered materials, thermal solutions, customizations, and improved processes for Cloud, Enterprise & 5G Applications.
- |
- +1 赞 0
- 收藏
- 评论 0
本文由ll转载自AAVID,原文标题为:Boyd-CDUs-and-Liquid-Cooling-for-Data-Centers.pdf,本站所有转载文章系出于传递更多信息之目的,且明确注明来源,不希望被转载的媒体或个人可与我们联系,我们将立即进行删除处理。
相关推荐
What Is A Coolant Distribution Unit (CDU)?
A Coolant Distribution Unit (CDU) is a system that enables smaller, more efficient, more precise liquid cooling in a data center at Rack level, often integrating facility water. The CDU circulates coolant in a closed loop system within the rack on the secondary (Cooling Application) side and utilizes facility water on the primary (Heat Rejection) side. A CDU has a pump, reservoir, power supply, control board and a heat-exchanger as the key components. Filters, flow meters, pressure transducers, and other devices are also used in managing the operation of the CDU in conjunction with the Server
【技术】爱美达使用铜水微型热管和k-Core封装石墨散热器开发组合解决方案,获得航天飞行认证
Boyd公司热能部门爱美达Aavid使用铜水微型热管和k-Core封装的石墨散热器开发了一种组合解决方案,用于直接对高性能ASIC(倒装芯片和微处理器)进行热管理,并已成功获得航天飞行认证。该解决方案可实现高性能,组件级冷却以及增强的从机箱到空间散热器的机箱级别热传导。Aavid相信:这将使未来电信卫星有效载荷的散热量发生显著变化。
【技术】爱美达分割框架及流动切膜技术助力手机、显示屏防护膜的高效低成本制造,推动全球化生产
分割框架技术是一种高精度、卷轴到卷轴制造工艺,它利用爱美达公司专有的高速生产线来消除浪费、最大限度地提高材料利用率并优化组件成本。通过间隔和定向隔离衬垫、粘合带、光学薄膜和光学透明粘合剂消除材料浪费,这样切割材料可以最大限度地提高产量
液冷系统和CDU已成为数据中心热管理方案大势
下一代设计的热量和功率密度要求现在已经达到了空冷的极限,总而需要过渡到液冷技术。液冷系统通过提高设计灵活性和可扩展性来改进传热和获得更高的热性能,进而使应用程序能够更快、更经济、更安静、性能更好。更高效、更小的系统也节省了空间,允许更多的机架和服务器以更高的性能运行。
4U CDU(冷却液分配装置)技术数据表
描述- 该资料介绍了Boyd公司推出的4U液冷分配单元(CDU),这是一种先进的冷却系统,旨在提高计算芯片功率下的散热能力。该产品适用于数据中心部署、系统烧录测试或开发实验室测试,具有N+1冗余设计,内置电源和泵的冗余功能,以及大型LCD显示屏便于参数控制和显示。它支持快速现场安装和操作,并提供与Boyd机架歧管和冷板环路的无缝集成。
Nidec Starts Shipping OCP-standard, In-rack-type, 4U-size 250KW CDU to Supermicro
Nidec announced that it has started shipping a CDU as a new in-rack-type cooling solution for nextgeneration data centers. This latest product, jointly developed with Supermicro possesses a 4U-size, 250kW cooling capability, and meets the OCP standard.
【产品】爱美达冷却液分配单元(CDU),灵活省空间的超大规模计算系统冷却方案
BOYD的冷却液分配单元有助于降低数据中心的总体拥有成本。CDU尺寸合适且针对特定应用进行了定制配置,这意味着超大规模计算系统可在需要时获得系统所需的精确,最佳冷却性能。具有操作逻辑,自动诊断和故障排除,保护和警告功能以及智能流量,压力和温度控制功能的智能控制器可管理系统性能,以高峰需求达到峰值,同时在非峰值运行期间保持经济高效,并在故障发生之前预防问题发生。
10U CDU(冷却液分配装置)技术数据表
描述- Boyd公司推出的10U液冷分配单元(CDU)是一种高效系统,适用于数据中心或边缘服务器的高功率计算环境中,特别是在没有设施水源的情况下。该CDU能够提供超过30kW的冷却能力,具有N+1冗余电源和泵,支持多种通信协议,并具备泄漏检测功能。它可与Boyd的机架歧管和冷板回路无缝配合,为用户提供全面的端到端液冷解决方案。
爱美达机架式CDU和行级CDU助力数据中心散热,提供最高700千瓦冷却能力
自从数据中心首次出现和不断发展,爱美达一直引领着企业冷却和工程材料解决方案的技术创新,利用这几十年的专业知识开发了一系列先进的热解决方案和系统,,前瞻性液体冷却创新和系统元件——冷却液分配单元(CDUs)。
行内冷却液分配装置液体冷却解决方案
描述- 该资料介绍了Boyd公司生产的In-Row冷却解决方案,这是一种高性能的冷却分配单元(CDU),适用于服务器、数据中心、医疗、半导体和一般工业应用。该CDU利用设施水提供高效的冷却能力,具有305-850 kW的制冷能力和支持多个机架的能力。它具备冗余泵、先进的监测传感器和其他智能可靠的特点。
云数据中心如何以高概率目标技术取胜
描述- 本文探讨了针对数据中心内部空气流动管理和热管理的关键材料解决方案。涵盖了电磁屏蔽、空气流动管理、热解决方案、冷板和液体循环冷却系统、图形覆盖层以及两相增强远程空气冷却技术。文章详细介绍了各种材料和技术如何提高系统性能、可靠性和安全性。
【经验】爱美达CDU设计需要注意的5个事项
爱美达在CDU设计方面有丰富的经验,本文针对CDU机械设计、 通讯/控制器和监视器、泄漏检测/冷凝风险、维护、热交换器内容进行说明。
【经验】冷却液分配单元(CDU)用于云设备、企业设备及5G热管理设计时需要考虑的因素
本文中爱美达将介绍CDU用于云设备、企业设备以及5G热管理设计需要考虑的因素。冷却液分配单元(CDU)技术改进的液冷系统和集成方案,通过超越运行功率和应用要求的可扩展热管理计划,帮助原始设备制造商在相同的占用空间内提高计算密度,快速迭代设计并加快上市速度,提高效率和可靠性。
10U冷却液分配装置液体-空气冷却解决方案
描述- Boyd公司推出的10U液冷散热单元(CDU)是为数据中心或边缘服务器提供高效液体冷却解决方案的系统。该系统适用于没有设施水的场所,具有超过30kW的容量,支持快速现场安装和操作。它具备N+1冗余功能,内置泄漏检测,并支持多种通信协议。
Coolant Distribution Units (CDUs) That Help Lower Data Center Total Cost of Ownership and Maximize Power Density
Boyd’s Coolant Distribution Units (CDUs) help lower data center total cost of ownership. CDUs mean hyperscale compute systems get the exact, optimal cooling performance the system needs, when it needs it. Intelligent controllers manage system performance to spike with peak demand while remaining economical and efficient during non-peak operation and prevent problems before they occur. Blind mate quick disconnects with 360 swivel fittings make servicing systems fast for minimized maintenance downtime.